| Site Search | Product Search | IA Global Search |
...onsumption Rated voltage (V) 50 Hz 60 Hz % of rated voltage DC 12 320 37.5 5 % min. Approx. 3.9 W 24 155 155 100 39 2,580 200 19.2 10,400 Note: 1. The rated current and coil resistance are me...
https://www.ia.omron.com/products/family/965/specification.html
... Input signal Current signal: 4 to 20 mA (input impedance: 352 Ω) Internal adjuster: 50 kΩ (1/4 W) External adjuster: 50 kΩ (1/4 W) Output cycle rate 0 to 100% Control cycle 0.2 s Nu...
https://www.ia.omron.com/products/family/991/specification.html
... initials of the format name. A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 0 1 2 3 4 5 6 7 8 9 Those with the initials E for Control Components is a product of less than 34. E52 (Exclu...
https://www.ia.omron.com/products/index/control-components/E.html
... initials of the format name. A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 0 1 2 3 4 5 6 7 8 9 Those with the initials H for Control Components is a product of less than 31. H3CA H3CR-...
https://www.ia.omron.com/products/index/control-components/H.html
... initials of the format name. A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 0 1 2 3 4 5 6 7 8 9 Those with the initials K for Control Components is a product of less than 12. K3CV K3GN ...
https://www.ia.omron.com/products/index/control-components/K.html
...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 220 VAC 5 A (Resistive load) 220 VAC 2 A (Inductive load (cosφ = 0...
...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 220 VAC 5 A (Resistive load) 220 VAC 2 A (Inductive load (cosφ = 0...
...: 5 A Maximum switching power 1100 VA (Resistive load) 440 VA (Inductive load (cosφ = 0.4)) 120 W (Resistive load) 48 W (Inductive load (L/R = 7 ms)) Contact form DPDT Contact method...
...ge (Reset voltage) 80 % max. Maximum voltage 110 % (23 ℃) Power consumption Operate Approx. 1.3 W Release Approx. 0.6 W Contact Contact rated load 220 VAC 3 A (Resistive load) 220 VA...
...ge (Reset voltage) 80 % max. Maximum voltage 110 % (23 ℃) Power consumption Operate Approx. 1.3 W Release Approx. 0.6 W Contact Contact rated load 220 VAC 3 A (Resistive load) 220 VA...
...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 220 VAC 5 A (Resistive load) 220 VAC 2 A (Inductive load (cosφ = 0...
...: 5 A Maximum switching power 1100 VA (Resistive load) 440 VA (Inductive load (cosφ = 0.4)) 120 W (Resistive load) 48 W (Inductive load (L/R = 7 ms)) Contact form 3PDT Contact method...
...: 5 A Maximum switching power 1100 VA (Resistive load) 440 VA (Inductive load (cosφ = 0.4)) 120 W (Resistive load) 48 W (Inductive load (L/R = 7 ms)) Contact form 3PDT Contact method...
...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 220 VAC 5 A (Resistive load) 220 VAC 2 A (Inductive load (cosφ = 0...
...: 5 A Maximum switching power 1100 VA (Resistive load) 440 VA (Inductive load (cosφ = 0.4)) 120 W (Resistive load) 48 W (Inductive load (L/R = 7 ms)) Contact form 3PDT Contact method...
...: 5 A Maximum switching power 1100 VA (Resistive load) 440 VA (Inductive load (cosφ = 0.4)) 120 W (Resistive load) 48 W (Inductive load (L/R = 7 ms)) Contact form 3PDT Contact method...
...: 5 A Maximum switching power 1100 VA (Resistive load) 440 VA (Inductive load (cosφ = 0.4)) 120 W (Resistive load) 48 W (Inductive load (L/R = 7 ms)) Contact form 3PDT Contact method...
...: 5 A Maximum switching power 1100 VA (Resistive load) 440 VA (Inductive load (cosφ = 0.4)) 120 W (Resistive load) 48 W (Inductive load (L/R = 7 ms)) Contact form 3PDT Contact method...
...: 5 A Maximum switching power 1100 VA (Resistive load) 440 VA (Inductive load (cosφ = 0.4)) 120 W (Resistive load) 48 W (Inductive load (L/R = 7 ms)) Contact form 3PDT Contact method...
...: 5 A Maximum switching power 1100 VA (Resistive load) 440 VA (Inductive load (cosφ = 0.4)) 120 W (Resistive load) 48 W (Inductive load (L/R = 7 ms)) Contact form 3PDT Contact method...