Site Search | Product Search | IA Global Search |
...inimum interval of 10 ms) Continuous (minimum interval of 10 ms) Measuring accuracy ±0.1% FS ±1 digit max. (at 23 ±5°C) Output mode Input mode: Not 2-input independent measurement: HI-LO, ARE...
https://www.omron-ap.com/products/family/221/specification.html
...imulation tool for sequence and motion in a 3D environment • Advanced security function with 32 digit security password last update: April 1, 2020...
...t the ambient temperature of 23°C) Thermocouple: (±0.3% of PV or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.2% of PV or ±0.8°C, whichever is greater) ±1...
https://www.omron-ap.com/products/family/3219/specification.html
...ient temperature of 23°C) E5CC-800 Thermocouple: (±0.3% of PV or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.2% of PV or ±0.8°C, whichever is greater) ±1...
https://www.omron-ap.com/products/family/3220/specification.html
...t the ambient temperature of 23°C) Thermocouple: (±0.3% of PV or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.2% of PV or ±0.8°C, whichever is greater) ±1...
https://www.omron-ap.com/products/family/3221/specification.html
...imulation tool for sequence and motion in a 3D environment • Advanced security function with 32 digit security password last update: April 1, 2020...
...ccuracy Thermocouple: (See note 1.) (±0.5% of indicated value or ±1°C, whichever is greater) ±1 digit max. Platinum resistance thermometer: (±0.5% of indicated value or ±1°C, whichever is gre...
https://www.omron.co.id/products/family/3218/specification.html
...t the ambient temperature of 23°C) Thermocouple: (±0.3% of PV or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.2% of PV or ±0.8°C, whichever is greater) ±1...
https://www.omron.co.id/products/family/3219/specification.html
...t the ambient temperature of 23°C) Thermocouple: (±0.3% of PV or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.2% of PV or ±0.8°C, whichever is greater) ±1...
https://www.omron.co.id/products/family/3221/specification.html
...imulation tool for sequence and motion in a 3D environment • Advanced security function with 32 digit security password last update: April 1, 2020...
...t the ambient temperature of 23°C) Thermocouple: (±0.3% of PV or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.2% of PV or ±0.8°C, whichever is greater) ±1...
https://www.omron.com.au/products/family/3219/specification.html
...ient temperature of 23°C) E5CC-800 Thermocouple: (±0.3% of PV or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.2% of PV or ±0.8°C, whichever is greater) ±1...
https://www.omron.com.au/products/family/3220/specification.html
...t the ambient temperature of 23°C) Thermocouple: (±0.3% of PV or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.2% of PV or ±0.8°C, whichever is greater) ±1...
https://www.omron.com.au/products/family/3221/specification.html
...imulation tool for sequence and motion in a 3D environment • Advanced security function with 32 digit security password last update: April 1, 2020...
...ccuracy Thermocouple: (See note 1.) (±0.5% of indicated value or ±1°C, whichever is greater) ±1 digit max. Platinum resistance thermometer: (±0.5% of indicated value or ±1°C, whichever is gre...
https://www.omron.com.vn/products/family/3218/specification.html
...t the ambient temperature of 23°C) Thermocouple: (±0.3% of PV or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.2% of PV or ±0.8°C, whichever is greater) ±1...
https://www.omron.com.vn/products/family/3219/specification.html
...ient temperature of 23°C) E5CC-800 Thermocouple: (±0.3% of PV or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.2% of PV or ±0.8°C, whichever is greater) ±1...
https://www.omron.com.vn/products/family/3220/specification.html
...t the ambient temperature of 23°C) Thermocouple: (±0.3% of PV or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.2% of PV or ±0.8°C, whichever is greater) ±1...
https://www.omron.com.vn/products/family/3221/specification.html
.... *1 Conversion speed: 250 ms/ 4 inputs Accuracy: (±0.3% of PV or ±1°C, whichever is larger) ±1 digit max. *3 Thermocouple: R, S, K, J, T, L, B External connection Removable terminal block Cu...
https://www.fa.omron.co.jp/data_pdf/cat/cj1w-pts_pdc_ph41u_ad04u_ds_e_4_5_csm1632.pdf
...nt one degree at a time with a key, but with the shift key (<
https://www.fa.omron.co.jp/data_pdf/cat/e5_c-t_h187-e1_1_3_csm1018751.pdf