Site Search | Product Search | IA Global Search |
...otion control, and data trace reduce machine tuning and set-up. Browse All Versions Security 32-Digit Password Password can be set to protect each project, by copy inhibition function from ha...
https://www.omron-ap.com.my/solutions/software/automation-systems/sysmac-style/one-software/
...otion control, and data trace reduce machine tuning and set-up. Browse All Versions Security 32-Digit Password Password can be set to protect each project, by copy inhibition function from ha...
https://www.omron-ap.com.ph/solutions/software/automation-systems/sysmac-style/one-software/
...otion control, and data trace reduce machine tuning and set-up. Browse All Versions Security 32-Digit Password Password can be set to protect each project, by copy inhibition function from ha...
https://www.omron.co.id/solutions/software/automation-systems/sysmac-style/one-software/
...otion control, and data trace reduce machine tuning and set-up. Browse All Versions Security 32-Digit Password Password can be set to protect each project, by copy inhibition function from ha...
https://www.omron.com.au/solutions/software/automation-systems/sysmac-style/one-software/
...otion control, and data trace reduce machine tuning and set-up. Browse All Versions Security 32-Digit Password Password can be set to protect each project, by copy inhibition function from ha...
https://www.omron.com.vn/solutions/software/automation-systems/sysmac-style/one-software/
...pe setting applies to all 4 inputs. (±0.3% of indication value or ±1°C, whichever is larger) ±1 digit max. *2 Input type Indicator accuracy Input accuracy K1, K2, T, and N below -100°C ±2°C ±...
https://www.fa.omron.co.jp/data_pdf/closed/cat/drt2_devicenet_q102-e1_20_37_csm2147.pdf
... 4 1 2 3 4 ON 10 9 X101 87 87 NODE ADR 1 0 9 Unit No. switch This rotary switch sets the single-digit hexadecimal unit number of the Master on the DeviceNet network. X100 1 DR0 2 DR1 3 ESTP 4...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/i539-e1-03_3g3mv-pdrt2_3g3rv-pdrt2.pdf
... set value 2. Starting read address Specify the address of the data which you want to read in 4-digit hexadecimal. Refer to 1-5 Memory/Parameter Area Details for details on the starting addre...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/n096-01_k3nx_k3nv_k3nh_k3nr_k3np_k3nc.pdf
...counter mode; 0001: Pulse output mode CQM1-CPU44-EV1: Origin compensation setting for port 1 (4-digit BCD) Page 16 17 25, 63 DM 6612 00 to 15 CQM1-CPU44-EV1: Origin compensation setting for p...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w228-e1-08_cqm1_cpm1_cpm1a_srm1.pdf
... set value 2. Starting read address Specify the address of the data which you want to read in 4-digit hexadeci- mal. Refer to 1-5 Memory/Parameter Area Details for details on the starting add...
https://www.fa.omron.com.cn/data_pdf/closed/mnu/n096-01_k3nx_k3nv_k3nh_k3nr_k3np_k3nc.pdf
...f these PLCs, but the peripheral bus mode cannot be used in CPM2@ PLCs that have a 9 as the 4th digit of the lot number. (The lot number may be 4 or 5 digits long.) ●C200H, C1000H, and C2000H...
https://www.fa.omron.com.cn/data_pdf/closed/mnu/w417-e1-07_cs1w-cif31.pdf
...y (25 °C) (See note.) With Celsius selected: ± 0.3% of PV or ± 1 ° C, whichever is greater, ± 1 digit max. With fahrenheit selected: ± 0.3% of PV or ± 2 ° F, whichever is greater, ± 1 ...
https://www.ia.omron.com/products/family/1664/specification.html
...efreshed during overseeing processing. Use PRV(881) to read the most recent PVs. Data format: 8 digit hexadecimal Linear mode: 8000 0000 to 7FFF FFFF hex 0000 0000 to FFFF FFFF hex (for incre...
https://www.ia.omron.com/products/family/2712/specification.html
...0 to 999 Recommended frequency: 20 to 80 Hz *1 Measurement absolute accuracy Current ±1.0% FS±1 digit (at 10 to 30°C, CT variation is not included) *2 Sampling cycle Degradation level 1, degr...
https://www.ia.omron.com/products/family/3686/specification.html
...measurement Yes Yes 0.1 V 5 ms Measurement accuracy ±2% (percentage of output voltage value) ±1 digit Output current measurement Yes Yes 0.1 A 5 ms Measurement accuracy ±5% (percentage of rat...
https://www.ia.omron.com/products/family/3687/specification.html
...T3L Maximum heater current 50 A AC Resolution 0.1 A Overall accuracy (25°C) ±5% (full scale) ±1 digit Influence of temperature (0 to 55°C) ±2% (full scale) ±1 digit Conversion time 5...
https://www.ia.omron.com/products/family/3699/specification.html
...T3L Maximum heater current 50 A AC Resolution 0.1 A Overall accuracy (25°C) ±5% (full scale) ±1 digit Influence of temperature (0 to 55°C) ±2% (full scale) ±1 digit Conversion time 5...
https://www.ia.omron.com/products/family/3902/specification.html
...ion: 0.1 V, Precision of output voltage indication: ±2% (percentage of output voltage value, ±1 digit) *7. Resolution of output current indication: 0.1 A; Precision of output current indicati...
https://www.ia.omron.com/products/family/807/specification.html
...imulation tool for sequence and motion in a 3D environment • Advanced security function with 32 digit security password last update: April 1, 2020...
https://www.omron-ap.co.in/products/family/3077/feature.html
...ccuracy Thermocouple: (See note 1.) (±0.5% of indicated value or ±1°C, whichever is greater) ±1 digit max. Platinum resistance thermometer: (±0.5% of indicated value or ±1°C, whichever is gre...
https://www.omron-ap.co.in/products/family/3218/specification.html