Site Search | Product Search | IA Global Search |
...tional unit terminal number The terminal number of Terminals A is called "13" because the first digit of the terminal number is "1" as it is mounted on the left side of the main unit, and the...
https://www.fa.omron.co.jp/data_pdf/cat/j7mc_j233-e1_5_1_csm1074610.pdf
...chable between 50 ms (default) and 5 ms Influence of temperature Influence of voltage ±1% FS ±1 digit or less Installation influence Influence of EMS K3CV-1ADIA-IL3 K3CV-1ADIB-IL3 Instruction...
https://www.fa.omron.co.jp/data_pdf/cat/k3cv_h243-e1_1_1_csm1132260.pdf
...unications. 3000 0.000 2000 1000 −5.500 0.0 −11.00 1 MΩ min. Measurement ±0.1% full scale ± one digit max. (at accuracy 23±3°C) ±0.1% full scale ± one digit max. (at 23±5°C) 30.00 0....
https://www.fa.omron.co.jp/data_pdf/cat/k3gn_ds_e_7_2_csm253.pdf
... change in the input signal from 15% to 95% or 95% to 15%) Display error when using prescale ±1 digit Insulation resistance 20 MΩ min. (at 500 VDC) Dielectric strength 2,300 VAC for 1 min bet...
https://www.fa.omron.co.jp/data_pdf/cat/k3hb-c_ds_e_17_5_csm259.pdf
... to 99,999 Accuracy (at 23±5°C) Thermocouple input: (±0.3% PV or ±1°C, whichever is larger) ± 1 digit max. (See note.) Platinum resistance thermometer input: (±0.2% PV or ±0.8°C, whichever is...
https://www.fa.omron.co.jp/data_pdf/cat/k3hb-h_ds_e_14_6_csm260.pdf
...Characteristics Display range −19,999 to 99,999 Measurement accuracy (at 23±5°C) ±0.08% rgd ±1 digit (for voltage pulse/open collector sensors) Measurement range Functions F1, F3, and F4:(In...
https://www.fa.omron.co.jp/data_pdf/cat/k3hb-p_ds_e_16_5_csm261.pdf
...splay range −19,999 to 99,999 Measurement accuracy (at 23±5°C) Functions F1, F6: ±0.006% rgd ±1 digit (for voltage pulse/open collector sensors) Functions F2 to F5: ±0.02% rgd ±1 ...
https://www.fa.omron.co.jp/data_pdf/cat/k3hb-r_ds_e_16_5_csm262.pdf
... V ±11.000 V Input impedance 120 Ω max. 1 MΩ min. Accuracy (at 23±5°C) One input: ±0.1% F.S. ±1 digit max. Two inputs: ±0.2% F.S. ±1 digit max. Maximum absolute rated input ±31 mA ±1...
https://www.fa.omron.co.jp/data_pdf/cat/k3hb-s_ds_e_11_6_csm263.pdf
...ut impedance 1 MΩ min. Accuracy A a lc 0.00 to 199.99 mV B b lc 0.000 to 19.999 mV ±0.1% rdg ±1 digit max. ±0.1% rdg ±5 digits max. C c lc ±100.00 mV ±0.1% rdg ±3 digits max. D d lc ±199.99 m...
https://www.fa.omron.co.jp/data_pdf/cat/k3hb-v_ds_e_11_6_csm264.pdf
...9 mA 0.000 to 21.999m A 10 Ω max. K3HB-XAD DC current K3HB-XAA AC current Accuracy ±0.1%rdg ± 1 digit max. ±0.1%rdg ± 1 digit max. Allowable instantaneous overload (30 s) ±400 V ±200...
https://www.fa.omron.co.jp/data_pdf/cat/k3hb-x_ds_e_12_6_csm254.pdf
...in. Must be able to dependably switch a load current of 5 mA max. Measuring accuracy ±0.1%FS ±1 digit (at 23±5°C) Measurement method Cycle measurement Max. displayed digits 5 digits (−19999 t...
https://www.fa.omron.co.jp/data_pdf/cat/k3ma-f_ds_e_14_4_csm265.pdf
...e 1.000 to 5.000 V 0.000 to 5.000 V –5.000 to 5.000 V DC current Measuring accuracy ±0.1% FS ±1 digit max. (at 23±3°C) –10.00 to 10.00 V ±0.1% FS ±1 digit max. (at 23±5°C) 4.00 to 20...
https://www.fa.omron.co.jp/data_pdf/cat/k3ma-j_ds_e_13_5_csm255.pdf
...(at 23±5°C) (See note.) Thermocouple: (±0.5% of indication value or ±1°C, whichever greater) ±1 digit max. Platinum-resistance thermometer: (±0.5% of indication value or ±1°C, whichever great...
https://www.fa.omron.co.jp/data_pdf/cat/k3ma-l_ds_e_11_4_csm266.pdf
...: 24 VDC (maximum voltage: 26.4 VDC) Max. current: 50 mA, DC Transistor output Alarm ±1.0% FS±1 digit (at 10 to 30°C, CT variation is not included) *2 Parameters that can be output Degradatio...
https://www.fa.omron.co.jp/data_pdf/cat/k6cm_n218-e1_3_1_csm1060693.pdf
...: 24 VDC (maximum voltage: 26.4 VDC) Max. current: 50 mA, DC Transistor output Alarm ±1.0% FS±1 digit (at 10 to 30°C, CT variation is not included) *2 Parameters that can be output Degradatio...
https://www.fa.omron.co.jp/data_pdf/cat/k6cm_n218-e1_5_4_csm1060693.pdf
...rameter. (H) Up Key Increases the set value for the displayed parameter. (I) Shift Key Used for digit shift in the set value of the displayed parameter. (J) Unit Number Setting Switch Sets th...
https://www.fa.omron.co.jp/data_pdf/cat/k7dd_n234-e1_3_3_csm1124083.pdf
...s Measurement range 0.1 to 99.9 MΩ (0.0 MΩ for less than 0.1 MΩ) Measuring accuracy ±5% rdg. ±1 digit (at ambient temperature -10 to 55°C and ambient humidity 25% to 65%) Megger voltage 50 VD...
https://www.fa.omron.co.jp/data_pdf/cat/k7ge-mg_n225-e1_2_2_csm1106906.pdf
... 528.0 V AC Rated 600 V AC: 0.0 to 660.0 V AC Absolute accuracy of voltage/current: ±0.5% FS ±1 digit to the input range Conditions: • When sine waves are input continuously • Variations in C...
https://www.fa.omron.co.jp/data_pdf/cat/k7tm_n228-e1_3_3_csm1115712.pdf
...ltage Current Accuracy *1 Active power Reactive power Frequency Power factor KM50-C ±1.0% FS ±1 digit (at ambient temperature of 23 °C, rated input, and rated frequency). However, the accurac...
https://www.fa.omron.co.jp/data_pdf/cat/km50-c1-flk_ds_e_1_2_csm1039756.pdf
...ity Maximum transmission distance Maximum number of connected Power Monitors KM50-E ±1.0% FS ±1 digit (at ambient temperature of 23 °C, rated input, and rated frequency). However, the accurac...
https://www.fa.omron.co.jp/data_pdf/cat/km50-e1-flk_ds_e_1_3_csm1039757.pdf