Site Search | Product Search | IA Global Search |
...
...xed> 46.8 33.6
...3.2 4.0 *1 *2 7.6 8.6 9.5 10.5 11.4 12.4 13.3 14.3 15.2 16.2 17.1 18.1 19.0 digit ones digit (tens setting ) ( setting ) + DC24V - 4 7 G3PF 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 ...
https://www.fa.omron.co.jp/data_pdf/mnu/g3pf-ctb_-stb_inst-2798050-8b.pdf
...3.2 4.0 *1 *2 7.6 8.6 9.5 10.5 11.4 12.4 13.3 14.3 15.2 16.2 17.1 18.1 19.0 digit ones digit (tens setting ) ( setting ) + DC24V - 4 7 G3PF 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 ...
https://www.fa.omron.co.jp/data_pdf/mnu/g3pf-ctb_-stb_inst-2798050-8b_en.pdf
...4.8 6.0 *1 *2 8.4 9.5 10.5 11.6 12.6 13.7 14.7 15.8 16.8 17.9 18.9 20.0 21.0 digit ones digit (tens setting ) ( setting ) 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 ...
https://www.fa.omron.co.jp/data_pdf/mnu/g3pf_inst-1278628-4b.pdf
...4.8 6.0 *1 *2 8.4 9.5 10.5 11.6 12.6 13.7 14.7 15.8 16.8 17.9 18.9 20.0 21.0 digit ones digit (tens setting ) ( setting ) 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 ...
https://www.fa.omron.co.jp/data_pdf/mnu/g3pf_inst-1278628-4b_en.pdf
... Exceptions in accuracy Accuracy Input Type and Condition Input Type K,T in Lower -100°C ±2°C±1 digit max. Input Type L ±2°C±1 digit max. Input Type R,S in Lower 200°C ±3°C±1 ...
https://www.fa.omron.co.jp/data_pdf/mnu/gt1-ts04__-ts04_cst_inst-1615913-6d.pdf
...03 00 3 00 E 3F 00 1 00 9 1A 00 0 00 6 07 00 0000 0 00 1 0 00 2 03 The address is a 4-digit hexadecimal code. Each variable contains an eightdigit value in hexadecimal. Negative values are ex...
.... Set the DeviceNet node address (0 to 63) for the DeviceNet Communications Unit. Set the ten's digit using the upper rotary switch on the front panel, and the one's digit using the ...
https://www.fa.omron.co.jp/data_pdf/mnu/h119-e1-03_e5zn-drt.pdf
...and 60 s when this switch is OFF. Parameters Function 5-10 5.4 Initial Setting Leve l (1) 100’s digit Setting Displayed number PV auto reset 0 Disabled 1 Enabled 10’s digit PV/SP dis...
https://www.fa.omron.co.jp/data_pdf/mnu/h140-e1-02_e5csv_e5cs-u.pdf
...5. Setting the EtherCAT Node Address Use the two hexadecimal rotary switches to set the first digit (×160) and second digit (×161) of the EtherCAT node address for the EJ1 EtherCAT...
https://www.fa.omron.co.jp/data_pdf/mnu/h192-e1-02_ej1n-hfuc-ect.pdf
... to read, this manual describes the same parameters for channels grouped as follows: The second digit of the subindex is incremented. Data name Ch1 Measured Value INT Index [hex] Subindex [he...
https://www.fa.omron.co.jp/data_pdf/mnu/h238-e1-01_nx-htc____.pdf
...ut 1 OUT 1 is lit Control output 2 OUT 2 is lit 0.0 MODE (Default setting) OFF (disabled) First digit 0.0 Set value 0.0 ON (enabled) 1 Forecast Control output (OUT2) value Present value MODE ...
https://www.fa.omron.co.jp/data_pdf/mnu/h5cx-b_-n_inst-1148308-3b.pdf
...nts dp ----------..----..----..--- Decimal point position ------ otm1 hold No decimal point One digit after decimal point Two digits after decimal point Three digits after decimal point -----...
https://www.fa.omron.co.jp/data_pdf/mnu/h7bx_inst-1651863-2a.pdf
...nts dp ----------..----..----..--- Decimal point position ------ otm1 hold No decimal point One digit after decimal point Two digits after decimal point Three digits after decimal point -----...
https://www.fa.omron.co.jp/data_pdf/mnu/h7bx_inst-1651863-2a_en.pdf
...ubtraction counter (sub) is displayed only when the output mode is k-2, d, l or h. *2: Set each digit using the individual UP and DOWN Keys for the following configuration selection modes. 2-...
https://www.fa.omron.co.jp/data_pdf/mnu/h7cc-a__inst-5639664-5c.pdf
...1 Introduction 1-2 Nomenclature and Key Operations D DIO Position Drivers Front View Display (5-digit, 7-segment LEDs) Operation Keys (5 keys) Monitor Output Terminal CN5 (RS-232C) Communicat...
https://www.fa.omron.co.jp/data_pdf/mnu/i524-04_fnd-x__x_-srt.pdf
...ry to set parameters for speed and torque control, so do not change the settings. Parameter No. Digit Parameter Name Set Value Description Pn000 1 Control Mode Selection 1 Position control Pn...
https://www.fa.omron.co.jp/data_pdf/mnu/i538-e1-01_r88a-ncw152-drt.pdf
...the Unit has stopped, the indicator will flash 1 time in orange and 6 times in red. Orange: 10s digit, Red: 1s digit 1s 0.5 s 0.5 s 0.5 s 0.5 s 0.5 s Orange Red Red Red Red Red Red 2...
https://www.fa.omron.co.jp/data_pdf/mnu/i561-e1-08_r88m-g_r7d-bp.pdf
...VOMOTOR AND SERVO DRIVE USER'S MANUAL 1-3 Names and Functions Servo Drive Functions Display A 6-digit 7-segment LED display shows the drive status, alarm codes, parameters, and other informat...
https://www.fa.omron.co.jp/data_pdf/mnu/i571-e1-08_r88m-k_r88d-kt.pdf