Site Search | Product Search | IA Global Search |
...ous overload (30 s) K3HB-XVD DC voltage A a vd±199.99 V -199.99 to 219.99 V 10 MΩmin.±0.1%rdg±1 digit max. ±400 V B b vd±19.999 V -19.999 to 21.999 V 1 MΩmin.±200 V C c vd±1.9999 V -1.9999 to...
https://www.fa.omron.com.cn/data_pdf/cat/k3hb-x_ds_e_12_6_csm254.pdf
... min. Must be able to dependably switch a load current of 5 mA max. Measuring accuracy±0.1%FS±1 digit (at 23±5°C) Measurement method Cycle measurement Max. displayed digits 5 digits (−19999 t...
https://www.fa.omron.com.cn/data_pdf/cat/k3ma-f_ds_e_14_4_csm265.pdf
...ange Measuring accuracy Input impedance Displayable range DC voltage 1.000 to 5.000 V±0.1% FS±1 digit max. (at 23±3°C) 1 MΩmin.–19999 to 99999 (with scaling function) 0.000 to 5.000 V –5.000 ...
https://www.fa.omron.com.cn/data_pdf/cat/k3ma-j_ds_e_13_5_csm255.pdf
... Note: The indication accuracy of the K thermocouple at a temperature of−200 to 1300°C is±2°C±1 digit maximum. The indication accuracy of the T and N thermocouples at a temperature of−100°C o...
https://www.fa.omron.com.cn/data_pdf/cat/k3ma-l_ds_e_11_4_csm266.pdf
... 0 to 999 Recommended frequency: 20 to 80 Hz *1 Measurement absolute accuracy Current±1.0% FS±1 digit (at 10 to 30°C, CT variation is not included) *2 Sampling cycle Degradation level/degrada...
https://www.fa.omron.com.cn/data_pdf/cat/k6cm_n218-e1_3_1_csm1060693.pdf
... 0 to 999 Recommended frequency: 20 to 80 Hz *1 Measurement absolute accuracy Current±1.0% FS±1 digit (at 10 to 30°C, CT variation is not included) *2 Sampling cycle Degradation level 1, degr...
https://www.fa.omron.com.cn/data_pdf/cat/k6cm_n218-e1_5_4_csm1060693.pdf
...rameter. (H) Up Key Increases the set value for the displayed parameter. (I) Shift Key Used for digit shift in the set value of the displayed parameter. (J) Unit Number Setting Switch Sets th...
https://www.fa.omron.com.cn/data_pdf/cat/k7dd_n234-e1_3_3_csm1124083.pdf
....0~300.0 V 600 V范围:300.0~600.0 V 驱动频率45~245 Hz对于正弦波测量精度 (环境温度10~30ºC) 电流绝对精度:±0.5 %FS±1 digit 重复精度:±1 %rdg±1 digit •不包含CT的精度偏差 •驱动频率...
https://www.fa.omron.com.cn/data_pdf/cat/k7dd_sgte-cn5-667_1_2.pdf
...tions Measurement range 0.1 to 99.9 MΩ(0.0 MΩfor less than 0.1 MΩ) Measuring accuracy±5% rdg.±1 digit (at ambient temperature -10 to 55°C and ambient humidity 25% to 65%) Megger voltage 50 VD...
https://www.fa.omron.com.cn/data_pdf/cat/k7ge-mg_n225-e1_2_2_csm1106906.pdf
...00 V AC: 0.0 to 660.0 V AC Measurement accuracy Absolute accuracy of voltage/current:±0.5% FS±1 digit to the input range Conditions: •When sine waves are input continuously •Variations in CTs...
https://www.fa.omron.com.cn/data_pdf/cat/k7tm_n228-e1_3_3_csm1115712.pdf
...V:AC0.0~264.0 V 额定AC480 V:AC0.0~528.0 V 额定AC600 V:AC0.0~660.0 V 测量精度电压/电流测量精度:相对于输入范围±0.5 %FS±1 digit [条件] •正弦波连续输入时 •不包含CT的精度偏差电阻值重复精...
https://www.fa.omron.com.cn/data_pdf/cat/k7tm_sgte-cn5-666_1_2.pdf
...his button. (Enabled when latch is enabled.) (See note 2.) Alarm setting rotary switch Set each digit of the alarm set temperature. K8AB-TH11S: x1, x10, x100 digits K8AB-TH12S: x10, x100, x10...
https://www.fa.omron.com.cn/data_pdf/cat/k8ab-th_ds_e_3_3_csm213.pdf
...器断线报警输出中停止累计。 报警解除侧从报警发生前的累计时间开始继续累计。 加热器1电流显示校正值isc1-999~999 digit 校正用测量参数CT1设定的CT1的加热器电流测量表示值。 •断电时保存数值。 加热器...
https://www.fa.omron.com.cn/data_pdf/cat/k8ac-h_ca_c_10_1.pdf
...e parameters are displayed, and to put set values in change status. Used to shift the set value digit when the set value is in change status. Mode key Used to switch the displayed parameter. ...
https://www.fa.omron.com.cn/data_pdf/cat/k8ac-h_n137-e1_10_1_csm1991.pdf
... KM50-E1-FLK 4 Performance Smart Power Monitor Item Model KM50-E Accuracy *1 Voltage ±1.0% FS±1 digit (at ambient temperature of 23°C, rated input, and rated frequency). However, the accuracy...
https://www.fa.omron.com.cn/data_pdf/cat/km50-e1-flk_ds_e_1_3_csm1039757.pdf
...uare Round Selection precautions Model Model Model M2PJ-7010-1 M2PA-7010-1 M2PT-7010-2 •The end digit denotes the color of the flange: -1 denotes a black flange, and -2 denotes a light gray f...
https://www.fa.omron.com.cn/data_pdf/cat/m2p_ds_e_6_1_csm616.pdf
...ng decimal point.) ABCD Data inputs Applicable to Decimal/ Hexadecimal Display Unit •Displays a digit or symbol corresponding to the value of the binary code signal. •Decimal display uses 0 t...
https://www.fa.omron.com.cn/data_pdf/cat/m7e(14mm)_ds_e_5_2_csm31.pdf
...eceived Terminal No. XG4- 2034 pin No. Terminal symbol Name Function 1(20)LE1 Control input 1st-digit latch input: The previous display is held when this signal is input. 2(18)LE2 Control inp...
https://www.fa.omron.com.cn/data_pdf/cat/m7e(80_120_200mm)_ds_e_10_3_csm34.pdf
...d RBI is low. Example 1: Zero blanking is not required and the RBI input and RBO output of each digit are open. Example 2: Wired as shown when there is zero blanking. If the data of the right...
https://www.fa.omron.com.cn/data_pdf/cat/m7e_25mm_ds_e_4_3_csm33.pdf
...2 1 Mother Board for Display Units (Character Height: 14 mm) M7E Compact (Two-, Three-, or Four-digit) S2- series Added to Static Mother Board Models •Easily connect a M7E Digital Display wit...
https://www.fa.omron.com.cn/data_pdf/cat/m7e_mother(14mm)_ds_e_2_2_csm32.pdf