PDFCSM_K3HB-X_DS_E_12_6 1 Process Indicator K3HB-X

...ous overload (30 s) K3HB-XVD DC voltage A a vd±199.99 V -199.99 to 219.99 V 10 MΩmin.±0.1%rdg±1 digit max. ±400 V B b vd±19.999 V -19.999 to 21.999 V 1 MΩmin.±200 V C c vd±1.9999 V -1.9999 to...

https://www.fa.omron.com.cn/data_pdf/cat/k3hb-x_ds_e_12_6_csm254.pdf

PDFCSM_K3MA-F_DS_E_14_4 1 Frequency/Rate Meter K3MA-F

... min. Must be able to dependably switch a load current of 5 mA max. Measuring accuracy±0.1%FS±1 digit (at 23±5°C) Measurement method Cycle measurement Max. displayed digits 5 digits (−19999 t...

https://www.fa.omron.com.cn/data_pdf/cat/k3ma-f_ds_e_14_4_csm265.pdf

PDFCSM_K3MA-J_DS_E_13_5 1 Process Meter K3MA-J

...ange Measuring accuracy Input impedance Displayable range DC voltage 1.000 to 5.000 V±0.1% FS±1 digit max. (at 23±3°C) 1 MΩmin.–19999 to 99999 (with scaling function) 0.000 to 5.000 V –5.000 ...

https://www.fa.omron.com.cn/data_pdf/cat/k3ma-j_ds_e_13_5_csm255.pdf

PDF1 CSM_K3MA-L_DS_E_11_4 Temperature Meter K3MA-L

... Note: The indication accuracy of the K thermocouple at a temperature of−200 to 1300°C is±2°C±1 digit maximum. The indication accuracy of the T and N thermocouples at a temperature of−100°C o...

https://www.fa.omron.com.cn/data_pdf/cat/k3ma-l_ds_e_11_4_csm266.pdf

PDF1 Motor Condition Monitoring Device

... 0 to 999 Recommended frequency: 20 to 80 Hz *1 Measurement absolute accuracy Current±1.0% FS±1 digit (at 10 to 30°C, CT variation is not included) *2 Sampling cycle Degradation level/degrada...

https://www.fa.omron.com.cn/data_pdf/cat/k6cm_n218-e1_3_1_csm1060693.pdf

PDF1 Motor Condition Monitoring Device K6CM-CI

... 0 to 999 Recommended frequency: 20 to 80 Hz *1 Measurement absolute accuracy Current±1.0% FS±1 digit (at 10 to 30°C, CT variation is not included) *2 Sampling cycle Degradation level 1, degr...

https://www.fa.omron.com.cn/data_pdf/cat/k6cm_n218-e1_5_4_csm1060693.pdf

PDF1 Advanced Motor Condition Monitoring Device K7DD

...rameter. (H) Up Key Increases the set value for the displayed parameter. (I) Shift Key Used for digit shift in the set value of the displayed parameter. (J) Unit Number Setting Switch Sets th...

https://www.fa.omron.com.cn/data_pdf/cat/k7dd_n234-e1_3_3_csm1124083.pdf

PDF高级电机状态监视器 K7DD 捕捉多种异常迹象 降低设备停机损失

....0~300.0 V 600 V范围:300.0~600.0 V 驱动频率45~245 Hz对于正弦波测量精度 (环境温度10~30ºC) 电流绝对精度:±0.5 %FS±1 digit 重复精度:±1 %rdg±1 digit •不包含CT的精度偏差 •驱动频率...

https://www.fa.omron.com.cn/data_pdf/cat/k7dd_sgte-cn5-667_1_2.pdf

PDF1 Insulation Resistance Monitoring Device K7GE-MG

...tions Measurement range 0.1 to 99.9 MΩ(0.0 MΩfor less than 0.1 MΩ) Measuring accuracy±5% rdg.±1 digit (at ambient temperature -10 to 55°C and ambient humidity 25% to 65%) Megger voltage 50 VD...

https://www.fa.omron.com.cn/data_pdf/cat/k7ge-mg_n225-e1_2_2_csm1106906.pdf

PDF1 Heater Condition Monitoring Device K7TM

...00 V AC: 0.0 to 660.0 V AC Measurement accuracy Absolute accuracy of voltage/current:±0.5% FS±1 digit to the input range Conditions: •When sine waves are input continuously •Variations in CTs...

https://www.fa.omron.com.cn/data_pdf/cat/k7tm_n228-e1_3_3_csm1115712.pdf

PDF清晰呈现人工无法捕捉的 加热器设备老化趋势 加热器状态监视器 K7TM

...V:AC0.0~264.0 V 额定AC480 V:AC0.0~528.0 V 额定AC600 V:AC0.0~660.0 V 测量精度电压/电流测量精度:相对于输入范围±0.5 %FS±1 digit [条件] •正弦波连续输入时 •不包含CT的精度偏差电阻值重复精...

https://www.fa.omron.com.cn/data_pdf/cat/k7tm_sgte-cn5-666_1_2.pdf

PDF1 CSM_K8AB-TH_DS_E_3_3 Temperature Monitoring Rela...

...his button. (Enabled when latch is enabled.) (See note 2.) Alarm setting rotary switch Set each digit of the alarm set temperature. K8AB-TH11S: x1, x10, x100 digits K8AB-TH12S: x10, x100, x10...

https://www.fa.omron.com.cn/data_pdf/cat/k8ab-th_ds_e_3_3_csm213.pdf

PDF1 400-820-4535 www.fa.omron.com.cn੼䆶⬉䆱᳔ᮄֵᙃܡ䌍

...器断线报警输出中停止累计。 报警解除侧从报警发生前的累计时间开始继续累计。 加热器1电流显示校正值isc1-999~999 digit 校正用测量参数CT1设定的CT1的加热器电流测量表示值。 •断电时保存数值。 加热器...

https://www.fa.omron.com.cn/data_pdf/cat/k8ac-h_ca_c_10_1.pdf

PDF1 Digital Heater Element Burnout Detector

...e parameters are displayed, and to put set values in change status. Used to shift the set value digit when the set value is in change status. Mode key Used to switch the displayed parameter. ...

https://www.fa.omron.com.cn/data_pdf/cat/k8ac-h_n137-e1_10_1_csm1991.pdf

PDFCSM_KM50-E1-FLK_DS_E_1_3 1 Smart Power Monitor

... KM50-E1-FLK 4 Performance Smart Power Monitor Item Model KM50-E Accuracy *1 Voltage ±1.0% FS±1 digit (at ambient temperature of 23°C, rated input, and rated frequency). However, the accuracy...

https://www.fa.omron.com.cn/data_pdf/cat/km50-e1-flk_ds_e_1_3_csm1039757.pdf

PDFCSM_M2P_DS_E_6_1 1 Indicator (Rectangular)

...uare Round Selection precautions Model Model Model M2PJ-7010-1 M2PA-7010-1 M2PT-7010-2 •The end digit denotes the color of the flange: -1 denotes a black flange, and -2 denotes a light gray f...

https://www.fa.omron.com.cn/data_pdf/cat/m2p_ds_e_6_1_csm616.pdf

PDFCSM_M7E(14mm)_DS_E_5_2 1 Digital Display (14 mm) M...

...ng decimal point.) ABCD Data inputs Applicable to Decimal/ Hexadecimal Display Unit •Displays a digit or symbol corresponding to the value of the binary code signal. •Decimal display uses 0 t...

https://www.fa.omron.com.cn/data_pdf/cat/m7e(14mm)_ds_e_5_2_csm31.pdf

PDFCSM_M7E(80_120_200mm)_DS_E_10_3

...eceived Terminal No. XG4- 2034 pin No. Terminal symbol Name Function 1(20)LE1 Control input 1st-digit latch input: The previous display is held when this signal is input. 2(18)LE2 Control inp...

https://www.fa.omron.com.cn/data_pdf/cat/m7e(80_120_200mm)_ds_e_10_3_csm34.pdf

PDFCSM_M7E_25mm_DS_E_4_3 1 Digital Display (25 mm) M7...

...d RBI is low. Example 1: Zero blanking is not required and the RBI input and RBO output of each digit are open. Example 2: Wired as shown when there is zero blanking. If the data of the right...

https://www.fa.omron.com.cn/data_pdf/cat/m7e_25mm_ds_e_4_3_csm33.pdf

PDFCSM_M7E_mother(14mm)_DS_E_2_2 1

...2 1 Mother Board for Display Units (Character Height: 14 mm) M7E Compact (Two-, Three-, or Four-digit) S2- series Added to Static Mother Board Models •Easily connect a M7E Digital Display wit...

https://www.fa.omron.com.cn/data_pdf/cat/m7e_mother(14mm)_ds_e_2_2_csm32.pdf