Primary Contents

IA Global Search Results

Select Country in

Site Search Product Search IA Global Search
Results 5141 - 5160 of 55080
E3Z-R61 2M | OMRON Industrial Automation

...tion 30 mA max. Control output NPN open collector 26.4 VDC max. 100 mA max. Residual voltage: 1 V max. (Load current Less than 10 mA) Residual voltage: 2 V max. (Load current 10 to 1...

https://www.ia.omron.com/product/item/711/

E3Z-R66 | OMRON Industrial Automation

...tion 30 mA max. Control output NPN open collector 26.4 VDC max. 100 mA max. Residual voltage: 1 V max. (Load current Less than 10 mA) Residual voltage: 2 V max. (Load current 10 to 1...

https://www.ia.omron.com/product/item/719/

EE-SX954-C1J-R 0.3M | OMRON Industrial Automation

...r supply voltage 5 to 24 VDC Load curren 50 mA max. Residual voltage at 50 mA load current: 0.7 V max. at 5 mA load current: 0.4 V max. Protection circuits Output short-cut protectio...

https://www.ia.omron.com/product/item/71972/

EE-SA801A 1M | OMRON Industrial Automation

...e (p-p) 10 % max. Current consumption 35 mA External diagnosis input Emission OFF: Shorted to 0 V or 0.5 V max. (source current: 30 mA max.) Emission ON: Open (leakage current: 0.4 m...

https://www.ia.omron.com/product/item/72054/

EE-SA801R 1M | OMRON Industrial Automation

...max. Current consumption 35 mA External diagnosis input Emission OFF: Shorted to +DC or +DC-0.5 V max. (sink current: 30 mA max.) Emission ON: Open (leakage current: 0.4 mA max.) Control outp...

https://www.ia.omron.com/product/item/72055/

E3Z-R81 2M | OMRON Industrial Automation

...tion 30 mA max. Control output PNP open collector 26.4 VDC max. 100 mA max. Residual voltage: 1 V max. (Load current Less than 10 mA) Residual voltage: 2 V max. (Load current 10 to 1...

https://www.ia.omron.com/product/item/721/

E5DC-QX2DBM-000 | OMRON Industrial Automation

... 2 A (resistive load), Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference value) Setting method Digital setting using front panel keys (with protection func...

https://www.ia.omron.com/product/item/72836/

E5DC-QX2DBM-002 | OMRON Industrial Automation

... 2 A (resistive load), Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference value) Setting method Digital setting using front panel keys (with protection func...

https://www.ia.omron.com/product/item/72837/

E5DC-RX0ABM-015 | OMRON Industrial Automation

...Relay output 1 point SPST-NO, 250 VAC, 3 A (resistive load) Minimum applicable load: 10 mA at 5 V (reference value) Setting method Digital setting using front panel keys (with protection func...

https://www.ia.omron.com/product/item/72838/

E5DC-RX0DBM-015 | OMRON Industrial Automation

...Relay output 1 point SPST-NO, 250 VAC, 3 A (resistive load) Minimum applicable load: 10 mA at 5 V (reference value) Setting method Digital setting using front panel keys (with protection func...

https://www.ia.omron.com/product/item/72839/

E5DC-RX2ABM-002 | OMRON Industrial Automation

...Relay output 1 point SPST-NO, 250 VAC, 3 A (resistive load) Minimum applicable load: 10 mA at 5 V (reference value) Auxiliary output Number of total auxiliary output 2 point Relay output SPST...

https://www.ia.omron.com/product/item/72840/

E5DC-RX2DBM-000 | OMRON Industrial Automation

...Relay output 1 point SPST-NO, 250 VAC, 3 A (resistive load) Minimum applicable load: 10 mA at 5 V (reference value) Auxiliary output Number of total auxiliary output 2 point Relay output SPST...

https://www.ia.omron.com/product/item/72841/

E5DC-RX2DBM-002 | OMRON Industrial Automation

...Relay output 1 point SPST-NO, 250 VAC, 3 A (resistive load) Minimum applicable load: 10 mA at 5 V (reference value) Auxiliary output Number of total auxiliary output 2 point Relay output SPST...

https://www.ia.omron.com/product/item/72842/

E3Z-R86 | OMRON Industrial Automation

...tion 30 mA max. Control output PNP open collector 26.4 VDC max. 100 mA max. Residual voltage: 1 V max. (Load current Less than 10 mA) Residual voltage: 2 V max. (Load current 10 to 1...

https://www.ia.omron.com/product/item/729/

NX-HTC3510-5 | OMRON Industrial Automation

...Pt100 (Three-wires) , Pt1000 (Three-wires) , Current (4 to 20 mA, 0 to 20 mA) , Voltage (1 to 5 V, 0 to 5 V, 0 to 10 V) Influence of conductor resistance Thermocouple input:...

https://www.ia.omron.com/product/item/73083/

NX-HTC4505-5 | OMRON Industrial Automation

...Pt100 (Three-wires) , Pt1000 (Three-wires) , Current (4 to 20 mA, 0 to 20 mA) , Voltage (1 to 5 V, 0 to 5 V, 0 to 10 V) Influence of conductor resistance Thermocouple input:...

https://www.ia.omron.com/product/item/73084/

E2CY-SD41 2M | OMRON Industrial Automation

...rol output (Switching capacity) 100 mA max. (26.4 VDC max.) Control output (Residual voltage) 1 V max. Indicator Operation indicator (orange) Operation mode NO/NC selectable Sensitivity setti...

https://www.ia.omron.com/product/item/73095/

E3Z-T61 2M | OMRON Industrial Automation

...ver: 20 mA max. Control output NPN open collector 26.4 VDC max. 100 mA max. Residual voltage: 1 V max. (Load current Less than 10 mA) Residual voltage: 2 V max. (Load current 10 to 1...

https://www.ia.omron.com/product/item/731/

G3RV-ST500-D AC200 | OMRON Industrial Automation

...t Rated voltage 200 VAC Rated current AC (50 Hz): 6.7 mA AC (60 Hz): 7.9 mA Operate voltage 180 V max. Release voltage 1 V min. Output Rated load voltage 5 to 24 VDC Load voltage ran...

https://www.ia.omron.com/product/item/73128/

G3RV-ST500-D AC230 | OMRON Industrial Automation

...t Rated voltage 230 VAC Rated current AC (50 Hz): 7.5 mA AC (60 Hz): 8.8 mA Operate voltage 207 V max. Release voltage 1 V min. Output Rated load voltage 5 to 24 VDC Load voltage ran...

https://www.ia.omron.com/product/item/73129/

Results 5141 - 5160 of 55080