...e 120 x 120 x t38 mm Rated voltage 100 to 240 VAC Permitted voltage fluctuation range 90 to 264 V Rated current (Nominal value) 0.08 A Rated input (Nominal value) 4.4 W Rated rotational speed...
...er Supplies > Related equipment > S8V-NF > Item list >S8V-NFS203 Noise Filter (Single-phase 250 V 3 A / 6 A Type) English 日本語 Print Page Image Rated voltage 250 VAC 50/60 Hz, 250 VDC Rated...
...er Supplies > Related equipment > S8V-NF > Item list >S8V-NFS206 Noise Filter (Single-phase 250 V 3 A / 6 A Type) English 日本語 Print Page Image Rated voltage 250 VAC 50/60 Hz, 250 VDC Rated...
...ntrol output (Switching capacity) 100 mA max. (30 VDC max.) Control output (Residual voltage) 1 V max. (Load current 100 mA with cable length of 2 m) Indicator Detection indicator (red) Opera...
...0.8 mA max. Control output (Switching capacity) 3 to 100 mA Control output (Residual voltage) 3 V max. (Load current 100 mA with cable length of 2 m) Indicator Operation indicator (red), Oper...
...0.8 mA max. Control output (Switching capacity) 3 to 100 mA Control output (Residual voltage) 3 V max. (Load current 100 mA with cable length of 2 m) Indicator Operation indicator (red), Oper...
...0.8 mA max. Control output (Switching capacity) 3 to 100 mA Control output (Residual voltage) 3 V max. (Load current 100 mA with cable length of 2 m) Indicator Operation indicator (red), Oper...
...0.8 mA max. Control output (Switching capacity) 3 to 100 mA Control output (Residual voltage) 3 V max. (Load current 100 mA with cable length of 2 m) Indicator Operation indicator (red), Oper...
... 0.8 mA max. Control output (Switching capacity) 3 to 50 mA Control output (Residual voltage) 3 V max. (Load current 50 mA with cable length of 1 m) Indicator Operation indicator (orange), Op...
... 0.8 mA max. Control output (Switching capacity) 3 to 50 mA Control output (Residual voltage) 3 V max. (Load current 50 mA with cable length of 1 m) Indicator Operation indicator (orange) Ope...
... 0.8 mA max. Control output (Switching capacity) 3 to 50 mA Control output (Residual voltage) 3 V max. (Load current 50 mA with cable length of 1 m) Indicator Operation indicator (orange) Ope...
...ontrol output (Switching capacity) 50 mA max. (30 VDC max.) Control output (Residual voltage) 1 V max. (Load current 50 mA with cable length of 1 m) Indicator Operation indicator (orange) Ope...
... 0.8 mA max. Control output (Switching capacity) 3 to 50 mA Control output (Residual voltage) 3 V max. (Load current 50 mA with cable length of 1 m) Indicator Operation indicator (orange), Op...
...ontrol output (Switching capacity) 50 mA max. (30 VDC max.) Control output (Residual voltage) 1 V max. (Load current 50 mA with cable length of 1 m) Indicator Operation indicator (orange) Ope...
...ontrol output (Switching capacity) 50 mA max. (30 VDC max.) Control output (Residual voltage) 1 V max. (Load current 50 mA with cable length of 1 m) Indicator Operation indicator (orange) Ope...
...ing capacity) at 12 VDC: 100 mA max. at 24 VDC: 200 mA max. Control output (Residual voltage) 1 V max. (at 200 mA load current) Indicator Detection indicator (red) Operation mode NC Protectiv...
...ing capacity) at 12 VDC: 100 mA max. at 24 VDC: 200 mA max. Control output (Residual voltage) 1 V max. (at 200 mA load current) Indicator Detection indicator (red) Operation mode NC Protectiv...
...ntrol output (Switching capacity) 100 mA max. (30 VDC max.) Control output (Residual voltage) 1 V max. (Load current 100 mA with cable length of 2 m) Indicator Detection indicator (red) Opera...
...8 mA max. Control output (Switching capacity) 3 to 100 mA Control output (Residual voltage) 3.3 V max. (Load current 100 mA with cable length of 2 m) Indicator Operation indicator (red) Opera...
...mption 30 mA max. Control output PNP open collector 30 VDC max. 100 mA max. Residual voltage: 3 V max. Operation mode Light-ON/Dark-ON selectable Protective circuit Output short-circuit prote...