Site Search | Product Search | IA Global Search |
...couple type (Ambient temperature:23°C) (±1.0% of indication value or ±2°C, which is greater) ±1 digit max. Platinum resistance thermometer type (±0.5% of indication value or ±1°C, which is gr...
https://www.omron-ap.co.in/data_pdf/mnu/e5cs-u_inst-2162665-6a.pdf
...A(100 to 240V AC) Approx. 4VA(24V AC)/Approx. 3W(24V DC) Indication accuracy E5CS: ±1.0 % FS ±1 digit max. E5CS-X: ±0.5 % FS ±1 digit max. Control output Relay output: 250V AC 3A(res...
https://www.omron-ap.co.in/data_pdf/mnu/e5cs_former_model_inst-1618455-6a.pdf
...1.5 W max. (24 VDC) Thermocouple: (±0.3 % of indication value or ±1°C, whichever is greater) ±1 digit max. Platinum resistance thermometer: (±0.2 % of indication value or ±0.8°C, whichever is...
https://www.omron-ap.co.in/data_pdf/mnu/e5dc-b_inst-2826078-9b.pdf
...试工具端口上。 前面板的元件名称 Control output 1 92 +00.8 The default PF Setting parameter is for shifting the digit. This is a function key. When it is pressed, the function set for the PF S...
https://www.omron-ap.co.in/data_pdf/mnu/e5dc_inst-5377468-1a.pdf
...g" of the advanced function setting level. The default PF Setting parameter is for shifting the digit. • No. 3 display Program No., segment No,. segment remaining time or MV (valve opening) •...
https://www.omron-ap.co.in/data_pdf/mnu/e5ec-t_inst-2285660-4c.pdf
...g" of the advanced function setting level. The default PF Setting parameter is for shifting the digit. • No. 3 display Program No., segment No,. segment remaining time or MV (valve opening) •...
https://www.omron-ap.co.in/data_pdf/mnu/e5ec-t_inst-5377457-6a.pdf
...g" of the advanced function setting level. The default PF Setting parameter is for shifting the digit. • No. 3 display Program No., segment No,. segment remaining time or MV (valve opening) •...
https://www.omron-ap.co.in/data_pdf/mnu/e5ec-t_inst-5377458-4a.pdf
...F key) MV, Soak Time Remain, and Multi-SP. The default PF Setting parameter is for shifting the digit. This is a function key. When it is pressed, the function set for the PF Setting paramete...
https://www.omron-ap.co.in/data_pdf/mnu/e5ec_inst-5377452-5a.pdf
...F key) MV, Soak Time Remain, and Multi-SP. The default PF Setting parameter is for shifting the digit. This is a function key. When it is pressed, the function set for the PF Setting paramete...
https://www.omron-ap.co.in/data_pdf/mnu/e5ec_inst-5377453-3a.pdf
...uring adaptive control. • Up and Down keys The default PF Setting parameter is for shifting the digit. This is a function key. When it is pressed, the function set for the PF Setting paramete...
https://www.omron-ap.co.in/data_pdf/mnu/e5ed-8___inst-3101755-0b.pdf
... temperature: 23°C) Thermocouple: (±0.1 % of indication value or ±1°C, whichever is greater) ±1 digit max. Platinum resistance thermometer: (±0.1 % of indication value or ±0.5°C, whichever is...
https://www.omron-ap.co.in/data_pdf/mnu/e5ed-h_inst_3690382-6a.pdf
...uple: (Ambient temperature: 23°C) (±0.1 % of indication value or ±1°C, whichever is greater) ±1 digit max. Platinum resistance thermometer: (±0.1 % of indication value or ±0.5°C, whichever is...
https://www.omron-ap.co.in/data_pdf/mnu/e5en-h_inst-1661077-6e.pdf
...munications B(+) *2 V Operation indicators The default PF Setting parameter is for shifting the digit. This is a function key. When it is pressed, the function set for the PF Setting paramete...
https://www.omron-ap.co.in/data_pdf/mnu/e5gc_inst-5377470-3a.pdf
...ple, platinum resistance thermometer: (±0.5 % of indication value or ±1°C, which is greater) ±1 digit max. Analog input: ±0.5 % FS ±1 digit max. Relay output: SPST-NO, Control output...
https://www.omron-ap.co.in/data_pdf/mnu/e5gn_inst-0682727-0h.pdf
...uple: (Ambient temperature: 23°C) (±0.3 % of indication value or ±1°C, whichever is greater) ±1 digit max. Platinum resistance thermometer: (±0.2 % of indication value or ±0.8°C, whichever is...
https://www.omron-ap.co.in/data_pdf/mnu/e5gn_inst-1152112-0b.pdf
...uple: (Ambient temperature: 23°C) (±0.3 % of indication value or ±1°C, whichever is greater) ±1 digit max. Platinum resistance thermometer: (±0.2 % of indication value or ±0.8°C, whichever is...
https://www.omron-ap.co.in/data_pdf/mnu/e5gn_inst-2109299-6a.pdf
...) Regelausgang 100 to 240 VAC, 50/60 Hz 85% to 110% of the rated voltage Approx. 3 VA ±(1°C + 1 digit) max. E5L-C □ only. Accuracy of thermistor is not included. Relay output: 250 VAC, 10 A (...
https://www.omron-ap.co.in/data_pdf/mnu/e5l_inst-y8025-10023a.pdf
...r and lower limits. Window mode (selective method) Display method Numerical value indication: 4-digit 7-segment white LED with inverting function Status indicators:The content of indication ...
https://www.omron-ap.co.in/data_pdf/mnu/e8fc-25__series_inst-3129431-7f.pdf
...udged if the measured value is within the upper and lower limits. Numerical value indication: 4-digit 7-segment white LED with inverting function Status indicators:The content of indication ...
https://www.omron-ap.co.in/data_pdf/mnu/e8fc-25s_series_inst-5696355-8a.pdf
...he polarity setting to PNP. sys* * number ↔ tune ↔ Measured value Numerical value indication: 4-digit 7-segment white LED with inverting function Status indicator: The content of indication i...
https://www.omron-ap.co.in/data_pdf/mnu/e8pc-___s_series_inst-5696380-9b.pdf