... V ±11.000 V Input impedance 120 Ω max. 1 MΩ min. Accuracy (at 23±5°C) One input: ±0.1% F.S. ±1 digit max. Two inputs: ±0.2% F.S. ±1 digit max. Maximum absolute rated input ±31 mA ±1...
https://www.omron-ap.co.in/data_pdf/cat/k3hb-s_ds_e_11_6_csm263.pdf
...ut impedance 1 MΩ min. Accuracy A a lc 0.00 to 199.99 mV B b lc 0.000 to 19.999 mV ±0.1% rdg ±1 digit max. ±0.1% rdg ±5 digits max. C c lc ±100.00 mV ±0.1% rdg ±3 digits max. D d lc ±199.99 m...
https://www.omron-ap.co.in/data_pdf/cat/k3hb-v_ds_e_11_6_csm264.pdf
...9 mA 0.000 to 21.999m A 10 Ω max. K3HB-XAD DC current K3HB-XAA AC current Accuracy ±0.1%rdg ± 1 digit max. ±0.1%rdg ± 1 digit max. Allowable instantaneous overload (30 s) ±400 V ±200...
https://www.omron-ap.co.in/data_pdf/cat/k3hb-x_ds_e_12_6_csm254.pdf
...in. Must be able to dependably switch a load current of 5 mA max. Measuring accuracy ±0.1%FS ±1 digit (at 23±5°C) Measurement method Cycle measurement Max. displayed digits 5 digits (−19999 t...
https://www.omron-ap.co.in/data_pdf/cat/k3ma-f_ds_e_14_4_csm265.pdf
...e 1.000 to 5.000 V 0.000 to 5.000 V –5.000 to 5.000 V DC current Measuring accuracy ±0.1% FS ±1 digit max. (at 23±3°C) –10.00 to 10.00 V ±0.1% FS ±1 digit max. (at 23±5°C) 4.00 to 20...
https://www.omron-ap.co.in/data_pdf/cat/k3ma-j_ds_e_13_5_csm255.pdf
...(at 23±5°C) (See note.) Thermocouple: (±0.5% of indication value or ±1°C, whichever greater) ±1 digit max. Platinum-resistance thermometer: (±0.5% of indication value or ±1°C, whichever great...
https://www.omron-ap.co.in/data_pdf/cat/k3ma-l_ds_e_11_4_csm266.pdf
...: 24 VDC (maximum voltage: 26.4 VDC) Max. current: 50 mA, DC Transistor output Alarm ±1.0% FS±1 digit (at 10 to 30°C, CT variation is not included) *2 Parameters that can be output Degradatio...
https://www.omron-ap.co.in/data_pdf/cat/k6cm_n218-e1_3_1_csm1060693.pdf
...: 24 VDC (maximum voltage: 26.4 VDC) Max. current: 50 mA, DC Transistor output Alarm ±1.0% FS±1 digit (at 10 to 30°C, CT variation is not included) *2 Parameters that can be output Degradatio...
https://www.omron-ap.co.in/data_pdf/cat/k6cm_n218-e1_5_4_csm1060693.pdf
...rameter. (H) Up Key Increases the set value for the displayed parameter. (I) Shift Key Used for digit shift in the set value of the displayed parameter. (J) Unit Number Setting Switch Sets th...
https://www.omron-ap.co.in/data_pdf/cat/k7dd_n234-e1_3_3_csm1124083.pdf
...s Measurement range 0.1 to 99.9 MΩ (0.0 MΩ for less than 0.1 MΩ) Measuring accuracy ±5% rdg. ±1 digit (at ambient temperature -10 to 55°C and ambient humidity 25% to 65%) Megger voltage 50 VD...
https://www.omron-ap.co.in/data_pdf/cat/k7ge-mg_n225-e1_2_2_csm1106906.pdf
... 528.0 V AC Rated 600 V AC: 0.0 to 660.0 V AC Absolute accuracy of voltage/current: ±0.5% FS ±1 digit to the input range Conditions: • When sine waves are input continuously • Variations in C...
https://www.omron-ap.co.in/data_pdf/cat/k7tm_n228-e1_3_3_csm1115712.pdf
...ltage Current Accuracy *1 Active power Reactive power Frequency Power factor KM50-C ±1.0% FS ±1 digit (at ambient temperature of 23 °C, rated input, and rated frequency). However, the accurac...
https://www.omron-ap.co.in/data_pdf/cat/km50-c1-flk_ds_e_1_2_csm1039756.pdf
...ity Maximum transmission distance Maximum number of connected Power Monitors KM50-E ±1.0% FS ±1 digit (at ambient temperature of 23 °C, rated input, and rated frequency). However, the accurac...
https://www.omron-ap.co.in/data_pdf/cat/km50-e1-flk_ds_e_1_3_csm1039757.pdf
... Ordering set combinations: Refer to pages 3. Selection precautions Model M2PT-7010-2 • The end digit denotes the color of the flange: -1 denotes a black flange, and -2 denotes a light gray f...
https://www.omron-ap.co.in/data_pdf/cat/m2p_ds_e_6_1_csm616.pdf
...or the built-in EtherNet/IP port (PORT2A and PORT2B). Use the rotary switches and specify a two-digit hexadecimal number. (G) IP Address Switch 1 (x16, x1) Used for setting an IP address for ...
https://www.omron-ap.co.in/data_pdf/cat/nx-csg_f125-e1_4_1_csm1124266.pdf
...s depends on the type of Unit. (F) Rotary switches These rotary switches are used to set the 1s digit and 10s digit of the node address of the EtherCAT Coupler Unit as an EtherCAT sl...
https://www.omron-ap.co.in/data_pdf/cat/nx-ecc_ds_e_8_15_csm1012823.pdf
...erformed on the safety application data in the Safety CPU Unit. Seven-segment indicator The two-digit seven-segment indicator shows the detailed information on the Safety CPU Unit in the foll...
https://www.omron-ap.co.in/data_pdf/cat/nx-sl5_f124-e1_5_1_csm1124265.pdf
...tion Maximum inrush 1.0 A/point max., 10 ms current Overall accuracy ±5% (full scale) (25°C) ±1 digit Influence of temperature (0 to 55°C) ±2% (full scale) ±1 digit Conversion time 1...
https://www.omron-ap.co.in/data_pdf/cat/nx-ts_hb_ds_e_4_2_csm1057423.pdf
...imulation tool for sequence and motion in a 3D environment • Advanced security function with 32 digit security password Sysmac is a trademark or registered trademark of OMRON Corporation in J...
https://www.omron-ap.co.in/data_pdf/cat/nx1p_p115-e1_2_5_csm1055395.pdf
...ediate processing are both possible. Ladder diagram 1 to 7 steps per instruction Approx. 400 (3-digit function codes) Basic instructions: 0.02 µs min.; Special instructions: 0.04 µs min. CJ1G...