PDF[Z363-E1-07] ZW-8000[]/7000[]/5000[] Confocal Fibe...

... OFF. You cannot reset major fault level errors from the user program, the Sysmac Studio, or an NS-series PT. To recover from a major fault level error, remove the cause of the error, and eit...

https://www.fa.omron.co.jp/data_pdf/mnu/z363-e1-07_zw-_000.pdf

PDFVision Sensor FH Series Vision System

...0 cm • Height: 7.5 mm • Material: Iron • Surface: Conductive FH-XDM-L PHOENIX CONTACT • Length: NS 35/7.5 PERF NS 35/15 PERF 75.5/95.5/115.5/200 cm • Height: 15 mm • Material: Iron •...

https://www.fa.omron.co.jp/data_pdf/mnu/z366-e1-28_fh.pdf

PDF[Z396-E1-03] NX-CSG[][][] Communication Control Un...

...ite the variables with communications from external devices, with the Sysmac Studio, or with an NS/NA-series PT. Basically, system-defined variables are classified according to the function m...

https://www.fa.omron.co.jp/data_pdf/mnu/z396-e1-03_nx-csg.pdf

PDF[Z400-E1-09] GI-S[][][][][][] Safety I/O Terminal ...

...] LED x 12, [V1] [V0] LED, [IN] LED x 12, [V1] LED, [OUT] LED x 4, [MS] LED, LED, [MS] LED, [NS] LED, [NS] LED, [PORT LINK] LED x 2 [PORT LINK] LED x 2 [IP ADDRESS] switch x3 (M...

https://www.fa.omron.co.jp/data_pdf/mnu/z400-e1-09_gi-s.pdf

PDFVision Sensor FHV Series Smart Camera

...eft/right) Noise immunity Fast transient burst • DC power Direct infusion: 2kV, Pulse rising: 5 ns, Pulse width: 50 ns, Burst continuation time: 15 ms/ 0.75 ms, Period: 300 ms, Appli...

https://www.fa.omron.co.jp/data_pdf/mnu/z408-e1-11_fhv7h.pdf

PDF[Z413-E1-01] V330-F/V430-F-series Auto Focus Multi...

...g data links are operating normally. Below is the LED status in normal operation. MS: Lit Green NS: Lit Green COMM: Lit Yellow 100M or 10M: Lit Yellow 2 In the Network Configurator, check the...

https://www.fa.omron.co.jp/data_pdf/mnu/z413-e1-01_v330-f_v430-f.pdf

PDFFiber Laser Marker MX-Z2000H-V1 series

...aser oscillation type Pulse oscillation - Pulse cycle 10 kHz to 1000 kHz - Pulse width 1 to 500 ns - Class 4 NOHD*2 " ■ Radiation range (page 16)" Nominal Ocular Hazard Distance MPE*3 MPE for...

https://www.fa.omron.co.jp/data_pdf/mnu/z415-e1-10_mx-z2000h-v1.pdf

PDFFiber Laser Marker MX-Z2000H-V1 series

...aser oscillation type Pulse oscillation - Pulse cycle 10 kHz to 1000 kHz - Pulse width 1 to 500 ns - Class 4 NOHD*2 " ■ Radiation range (page 15)" Nominal Ocular Hazard Distance MPE*3 MPE for...

https://www.fa.omron.co.jp/data_pdf/mnu/z416-e1-10_mx-z2000h-v1.pdf

PDFVision Sensor FJ Series (Camera & Software Vision ...

...to 3736 FJ-SC5MGR: 0 to 12487 FJ-S5MGR: 0 to 12487 (Unit: Tick, FJ-S£ £££ Camera: 1 [Tick] = 8 [ns]) Set the delay time of packets between. Set for preventing packet-loss because of connectin...

https://www.fa.omron.co.jp/data_pdf/mnu/z428-e1-03_fj-s__g_fj-sc__g.pdf

PDF[Z436-E1-05] FH-505[]/SMDA-GS050B Vision System Ha...

...d behind/left and right Fast Transient Burst • DC power: Direct infusion: 2 kV, Pulse rising: 5 ns, Pulse width: 50 ns, Burst continuation time: 15 ms/0.75 ms, Period: 300 ms, Applic...

https://www.fa.omron.co.jp/data_pdf/mnu/z436-e1-05_fh.pdf

PDF[Z470-E1-01] ZS-HL-N Series Smart Sensors 2D CMOS ...

...on IP20 (IEC60529) Noise immunity 1,500 V peak-to-peak, pulse width 0.1 µs/1 µs, rising edge: 1 ns pulse Vibration resistance (destructive) 10 to 150 Hz, 0.7-mm double amplitude, 80 min each ...

https://www.fa.omron.co.jp/data_pdf/mnu/z470-e1-01_zs-hl-n.pdf

PDF[Z478-E1-01] V460-H Series Industrial Handheld DPM...

...g data links are operating normally. Below is the LED status in normal operation. MS: Lit Green NS: Lit Green COMM: Lit Yellow 100M or 10M: Lit Yellow 2 Check the LED indicators on the code r...

https://www.fa.omron.co.jp/data_pdf/mnu/z478-e1-01_v460-h.pdf

PDFZP-series EtherNet/IP™ Communication Unit

...ction Error Green/Red Flashing Initializing --- Not lit The Unit/input power is not supplied. l NS Indicator The network status indicator. This indicator shows the status of the EtherNet/IP n...

https://www.fa.omron.co.jp/data_pdf/mnu/z496-e1-02_zp-eip.pdf

PDFMachine Automation Controller NJ/NX-series

...LED indicators in normal status are as follows: U/IN PWN: Green lit MS: Green lit SS: Green lit NS: Green lit L/A ETH1: Green lit / Green flashing (Flashing while packets are being sent and r...

https://www.fa.omron.co.jp/data_pdf/mnu/z501-e1-01_zp-eip.pdf

PDFVision Sensor FHV7-AI Series AI Detection Camera

...ft/right) Noise immunity Fast transient burst • DC power Direct infusion: 2 kV, Pulse rising: 5 ns, Pulse width: 50 ns, Burst continuation time: 15 ms/0.75 ms, Period: 300 ms, Applic...

https://www.fa.omron.co.jp/data_pdf/mnu/z507-e1-02_fhv7x-c016-s__-w-01.pdf

PDF[1668182-7C] ZG2-DSU□□ スマートセンサ データストレージユニット 取扱説明書 ...

...er case, 1000 VAC, 50/60 Hz, 1 min 1500 V peak-to-peak, pulse width 0.1 μs/1 μs, rising edge: 1 ns pulse 10 to 150 Hz, 0.35-mm amplitude, 80 min each in X, Y, and Z directions 150m/s2 3 times...

https://www.fa.omron.co.jp/data_pdf/mnu/zg2-dsu___inst-1668182-7c.pdf

PDF[7934186-4G] ZS-DSU□□ スマートセンサ データストレージユニット 取扱説明書 (...

...er case, 1000 VAC, 50/60 Hz, 1 min 1500 V peak-to-peak, pulse width 0.1 μs/1 μs, rising edge: 1 ns pulse 10 to 150 Hz, 0.7-mm double amplitude, 80 min each in X, Y, and Z directions 300m/s2 3...

https://www.fa.omron.co.jp/data_pdf/mnu/zs-dsu___inst-7934186-4g.pdf

PDF3. Orientation when Installing the Sensor Controll...

...er case, 1000 VAC, 50/60 Hz, 1 min 1500 V peak-to-peak, pulse width 0.1 μs/1 μs, rising edge: 1 ns pulse 10 to 150 Hz, 0.7-mm double amplitude, 80 min each in X, Y, and Z directions 300 m/s2 ...

https://www.fa.omron.co.jp/data_pdf/mnu/zs-hldc__-n_inst-5727458-6b.pdf

PDF[7978908-3G] ZS-HLDC□□ スマートセンサ 形ZS-HLD□□□用 センサコントロ...

...er case, 1000 VAC, 50/60 Hz, 1 min 1500 V peak-to-peak, pulse width 0.1 μs/1 μs, rising edge: 1 ns pulse 10 to 150 Hz, 0.7-mm double amplitude, 80 min each in X, Y, and Z directions 300 m/s2 ...

https://www.fa.omron.co.jp/data_pdf/mnu/zs-hldc___inst-7978908-3g.pdf

PDFCSM_CJ1W-CRM21_DS_C_11_12 1 400-820-4535 www.fa.om...

...信电源电缆,推荐使用以下棒状端子。 此外,如需拆下棒状端子,推荐使用以下螺丝刀。 外形尺寸(单位:mm) CRM21 +100 MS NS SD RD MACH No. MODE X101 ON X100 BS+ BS- DC24V INPUT NETWORKPS BS+ BD H D...

https://www.fa.omron.com.cn/data_pdf/cat/cj1w-crm21_ds_c_11_12.pdf