Primary Contents

IA Global Search Results

Select Country in

Site Search Product Search IA Global Search
Results 5441 - 5460 of 10238
PDFCSM_EJ1_DS_E_12_5 1 Modular Temperature Controller

...ves) PC PLC DeviceNet Configurator or CX-Integrator DeviceNet Serial communications EJ1N DRT MS NS TS MAX No. NODE ADR COPY 123456 EDS UP/DN MODE TC2/4 NO 10 1 COM1 COM2 COM3 PWR RUN ERR ALM ...

https://www.fa.omron.com.cn/data_pdf/cat/ej1_ds_e_12_5_csm222.pdf

PDF1 模块式温控器 EJ1 控制柜内安装型温控器,灵活的模块化设计,

... PC EJ1N-HFU PLC EJ1N-TC4 EJ1N-TC2 EJ1C-EDU B B DeviceNet CX-Integrator C DeviceNet EJ1N DRT MS NS TS MAX No. NODE ADR COPY 123456 EDS UP/DN MODE TC2/4 NO ×10 ×1 EJ1N-HFU EJ1N-TC4 EJ1N-TC2 EJ...

https://www.fa.omron.com.cn/data_pdf/cat/ej1_sgtd-cn5-045e.pdf

PDF3D Robot Vision System FH-SMD Series

...and right Noise immunity Fast Transient Burst •DC power: Direct infusion: 2 kV, Pulse rising: 5 ns, Pulse width: 50 ns, Burst continuation time: 15 ms/0.75 ms, Period: 300 ms, Applic...

https://www.fa.omron.com.cn/data_pdf/cat/fh-smd_q298-e1_5_4_csm1108528.pdf

PDFAuthorized Distributor: Kyoto, JAPAN Contact : www...

...NIX CONTACT •Length: 75.5/95.5/115.5/200 cm •Height: 7.5mm •Material: Iron •Surface: Conductive NS 35/7,5 PERF •Length:75.5/95.5/115.5/200 cm •Height: 15mm •Material: Iron •Surface: Conductiv...

https://www.fa.omron.com.cn/data_pdf/cat/fh_q197-e1_29_1_csm1013479.pdf

PDF由AI替代熟练工 自动执行划痕和缺陷检测 图像处理系统 FH系列

...用) FH-XDM-L DIN35mm导轨 PHOENIX CONTACT株式会社 •长度: 75.5/95.5/115.5/200cm •高度:7.5mm •材质:铁 •表面加工:导电加工 NS 35/7,5 PERF •长度: 75.5/95.5/115.5/200cm •高度:15mm •材质:铁 •...

https://www.fa.omron.com.cn/data_pdf/cat/fh_sdnb-cn5-034_19_14.pdf

PDFSmart Camera FHV7 Series The flexibility meets

...left/right) Noise immunity Fast transient burst •DC power Direct infusion: 2kV, Pulse rising: 5 ns, Pulse width: 50 ns, Burst continuation time: 15 ms/0.75 ms, Period: 300 ms, Applic...

https://www.fa.omron.com.cn/data_pdf/cat/fhv7_q264-e1_8_2_csm1066920.pdf

PDFExpanded performance and functionality

...a•••• Color data•••• Labeling•••• ID Bar code ---- 2D code 2D code (DPM)* OCR I/O specif icatio ns Communications (Ethernet TCP no-protocol, Ethernet UDP no-protocol, Ethernet FINS/TCP no-pro...

https://www.fa.omron.com.cn/data_pdf/cat/fq2_q193-e1_15_2_csm1006918.pdf

PDFCSM_G3PF_DS_E_7_12 1 Solid State Relays with Built...

...value): 500 V Note: This value was measured under the following conditions. Noise duration: 100 ns and 1μs Repetition period: 100 Hz Noise application time: 3 min The SSR in operation may cau...

https://www.fa.omron.com.cn/data_pdf/cat/g3pf_ds_e_7_12_csm748.pdf

PDF1 Solid State Relays for Heaters

...value): 500 V Note: This value was measured under the following conditions. Noise duration: 100 ns and 1μs Repetition period: 100 Hz Noise application time: 3 min Mounting to Control Panel If...

https://www.fa.omron.com.cn/data_pdf/cat/g3pj_j210-e1_4_3_csm1050153.pdf

PDF1 I/O Relay Terminal G70V I/O Relay Terminals with...

... 3 times each in 6 directions along 3 axes Noise immunity Noise level: 1.5 kV; pulse width: 100 ns to 1μs Ambient operating temperature −40 to 55°C (with no icing or condensation) Ambient ope...

https://www.fa.omron.com.cn/data_pdf/cat/g70v_j215-e1_2_20_csm1050154.pdf

PDFCSM_G9B_DS_E_4_1 1 Stepping Relay Unit

...output terminals and power output terminals Noise immunity Noise level: 1.5 kV, pulse width: 50 ns/1µs (600 V for 24-VDC model) Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm si...

https://www.fa.omron.com.cn/data_pdf/cat/g9b_ds_e_4_1_csm53.pdf

PDF1 Low-speed Monitoring Unit G9SX-LM

...23 No. G9SX-EX401-T 24VDC ED ED ERR ERR G9SX-NS202 24VDC G9SX-LM224 24VDC OFF-DELAY No. No. AND NS FB ERR EI PWB PWB T1 FB AND MOD RD T2 T7 ED ERR EI T6 D4 L1 S24 S14 A2 X2 T42 T41 A1 X1 D2 D...

https://www.fa.omron.com.cn/data_pdf/cat/g9sx-lm_j172-e1_6_2_csm1807.pdf

PDF1 Safety I/O Terminal GI-S Series GI-SMD/SID

...ction unavailable LED indication [V0] LED, [IN…] LED x 12, [V1] LED, [OUT…] LED x 4, [MS] LED, [NS] LED, [PORT…LINK] LED x 2 [V0] LED, [IN…] LED x 12, [V1] LED, [MS] LED, [NS] LED, [...

https://www.fa.omron.com.cn/data_pdf/cat/gi-smd_sid_f126-e1_4_1_csm1124267.pdf

PDF1 CRT1-series Smart Slave Units 1

...cated four stations numbers as a remote device station L L RUN ERR RD SD RD REGIST RESET REG SD NS MS STAT ION No. X10 MODE X1 B.RATE DR0 DR1 DCN REGS DA DB DG SLD FG DC24V INPUT GQ-CRM21 1 2...

https://www.fa.omron.com.cn/data_pdf/cat/gq-crm21_p067-e1-01.pdf

PDFCSM_H3AM_DS_C_3_2 1 400-820-4535 www.fa.omron.com....

...、6min、60min、 6h、60h) (12s、120s、12min、 120min、12h) AC100~ 240V 自动复位接点输出2c 限时2c或(限时1c+瞬时1c)型号H3AM-NS-A H3AM-NS-B H3AM-NS-C 电气复位接点输出2c (限...

https://www.fa.omron.com.cn/data_pdf/cat/h3am_ds_c_3_2.pdf

PDFCSM_H3AM_DS_E_3_1 1 Mechatronic Analog Timer

...ables the building of a self-holding relay circuit as well as built-in instantaneous contact. (-NS) •Memory retention (-NSR) •Finger protection terminal block •Enables easy sequence checks th...

https://www.fa.omron.com.cn/data_pdf/cat/h3am_ds_e_3_1_csm83.pdf

PDFSolid-state Timer H3BF-N/BG-N/BH-N 1

...mmunity±1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width:100 ns/1μs, 1-ns rise) Static immunity Malfunction: 8 kV Destruction: 15 kV Vibration resi...

https://www.fa.omron.com.cn/data_pdf/cat/h3b_-n_l094-e1_2_3_csm1015158.pdf

PDFSolid-state Timer H3BA-N 1 Solid-state Timer

...s), and±600 V (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/1μs, 1-ns rise) DC models:±480 V (between power terminals), and±600 V (between inpu...

https://www.fa.omron.com.cn/data_pdf/cat/h3ba-n_l093-e1_2_3_csm1015157.pdf

PDFCSM_H3DS_DS_E_5_4 1 Solid-state Timer H3DS

...ng metal parts) Noise immunity Square-wave noise generated by noise simulator (pulse width: 100 ns/1μs, 1-ns rise)±1.5 kV Static immunity Malfunction: 4 kV Destruction: 8 kV Life exp...

https://www.fa.omron.com.cn/data_pdf/cat/h3ds_ds_e_5_4_csm88.pdf

PDF1 Solid-state timer H3RN-@-B Compact, Multi-functi...

...r terminals: 1 kV Noise immunity±1.5 kV, square-wave noise by noise simulator (pulse width: 100 ns/1μs, 1-ns rise) Static immunity Destruction: 8 kV Malfunction: 4 kV Degree of prote...

https://www.fa.omron.com.cn/data_pdf/cat/h3rn-_-b_m093-e1_1_5_csm1050150.pdf

Results 5441 - 5460 of 10238

Select Country in