G3RV-ST700-D-H AC/DC24 | OMRON Industrial Automati...

...nt resistivity 30 A (10 ms) Permissible I2**t 9 A 2 s Applicable load Load carrying capacity 72 W (Output voltage: 24 VDC) Performance Operate time 3 ms max. Release time 21 ms max.(1 cycle o...

https://www.ia.omron.com/product/item/73158/

G3RV-ST700-D-H DC24 | OMRON Industrial Automation

...nt resistivity 30 A (10 ms) Permissible I2**t 9 A 2 s Applicable load Load carrying capacity 72 W (Output voltage: 24 VDC) Performance Leakage current 10 µA max. (at 24 VDC) Insulation resist...

https://www.ia.omron.com/product/item/73159/

MY4F AC200/220 | OMRON Industrial Automation

...DC: 3 A Maximum switching power 660 VA (Resistive load) 176 VA (Inductive load (cosφ = 0.4)) 72 W (Resistive load) 36 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/7469/

MY4F AC24 | OMRON Industrial Automation

...DC: 3 A Maximum switching power 660 VA (Resistive load) 176 VA (Inductive load (cosφ = 0.4)) 72 W (Resistive load) 36 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/7470/

MY4F DC100/110 | OMRON Industrial Automation

...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 220 VAC 3 A (Resistive load) 220 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/7471/

MY4F DC12 | OMRON Industrial Automation

...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 220 VAC 3 A (Resistive load) 220 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/7472/

MY4F DC24 | OMRON Industrial Automation

...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 220 VAC 3 A (Resistive load) 220 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/7473/

MY4F DC48 | OMRON Industrial Automation

...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 220 VAC 3 A (Resistive load) 220 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/7475/

MY4H AC100/110 | OMRON Industrial Automation

... DC: 3 A Maximum switching power 330 VA (Resistive load) 88 VA (Inductive load (cosφ = 0.4)) 72 W (Resistive load) 36 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/7476/

MY4IN AC100/110 (S) | OMRON Industrial Automation

...: 5 A Maximum switching power 1250 VA (Resistive load) 200 VA (Inductive load (cosφ = 0.4)) 150 W (Resistive load) 45 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/7481/

MY4IN AC200/220 (S) | OMRON Industrial Automation

...: 5 A Maximum switching power 1250 VA (Resistive load) 200 VA (Inductive load (cosφ = 0.4)) 150 W (Resistive load) 45 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/7482/

MY4IN-CR AC100/110 (S) | OMRON Industrial Automati...

...: 5 A Maximum switching power 1250 VA (Resistive load) 200 VA (Inductive load (cosφ = 0.4)) 150 W (Resistive load) 45 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/7490/

MY4IN-D2 DC12 (S) | OMRON Industrial Automation

...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 250 VAC 3 A (Resistive load) 250 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/7492/

MY4IN-D2 DC24 (S) | OMRON Industrial Automation

...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 250 VAC 3 A (Resistive load) 250 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/7493/

MY4N AC100/110 | OMRON Industrial Automation

...DC: 3 A Maximum switching power 660 VA (Resistive load) 176 VA (Inductive load (cosφ = 0.4)) 72 W (Resistive load) 36 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/7494/

MY4N AC110/120 | OMRON Industrial Automation

...DC: 3 A Maximum switching power 660 VA (Resistive load) 176 VA (Inductive load (cosφ = 0.4)) 72 W (Resistive load) 36 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/7495/

MY4N AC12 | OMRON Industrial Automation

...DC: 3 A Maximum switching power 660 VA (Resistive load) 176 VA (Inductive load (cosφ = 0.4)) 72 W (Resistive load) 36 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/7496/

MY4N AC200/220 | OMRON Industrial Automation

...DC: 3 A Maximum switching power 660 VA (Resistive load) 176 VA (Inductive load (cosφ = 0.4)) 72 W (Resistive load) 36 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/7498/

MY4N AC220/240 | OMRON Industrial Automation

...DC: 3 A Maximum switching power 660 VA (Resistive load) 176 VA (Inductive load (cosφ = 0.4)) 72 W (Resistive load) 36 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/7499/

MY4N AC24 | OMRON Industrial Automation

...DC: 3 A Maximum switching power 660 VA (Resistive load) 176 VA (Inductive load (cosφ = 0.4)) 72 W (Resistive load) 36 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/7500/