MY4Z-02 DC48 | OMRON Industrial Automation

...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 220 VAC 3 A (Resistive load) 220 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/7537/

MY4Z-CR AC100/110 | OMRON Industrial Automation

...DC: 3 A Maximum switching power 660 VA (Resistive load) 176 VA (Inductive load (cosφ = 0.4)) 72 W (Resistive load) 36 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/7544/

MY4Z-CR AC200/220 | OMRON Industrial Automation

...DC: 3 A Maximum switching power 660 VA (Resistive load) 176 VA (Inductive load (cosφ = 0.4)) 72 W (Resistive load) 36 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/7545/

MY4Z-D DC100/110 | OMRON Industrial Automation

...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 220 VAC 3 A (Resistive load) 220 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/7546/

MY4Z-D DC12 | OMRON Industrial Automation

...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 220 VAC 3 A (Resistive load) 220 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/7547/

MY4ZF DC12 | OMRON Industrial Automation

...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 220 VAC 3 A (Resistive load) 220 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/7551/

MY4ZF DC24 | OMRON Industrial Automation

...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 220 VAC 3 A (Resistive load) 220 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/7552/

MY4ZH AC100/110 | OMRON Industrial Automation

... DC: 3 A Maximum switching power 330 VA (Resistive load) 88 VA (Inductive load (cosφ = 0.4)) 72 W (Resistive load) 36 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/7553/

MY4ZH AC110/120 | OMRON Industrial Automation

... DC: 3 A Maximum switching power 330 VA (Resistive load) 88 VA (Inductive load (cosφ = 0.4)) 72 W (Resistive load) 36 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/7554/

MY4ZH DC100/110 | OMRON Industrial Automation

...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 110 VAC 3 A (Resistive load) 110 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/7556/

MY4ZH DC12 | OMRON Industrial Automation

...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 110 VAC 3 A (Resistive load) 110 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/7557/

MY4ZH DC48 | OMRON Industrial Automation

...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 110 VAC 3 A (Resistive load) 110 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/7560/

MY4ZIN AC100/110 (S) | OMRON Industrial Automation

...: 5 A Maximum switching power 1250 VA (Resistive load) 200 VA (Inductive load (cosφ = 0.4)) 150 W (Resistive load) 45 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/7561/

MY4ZIN AC200/220 (S) | OMRON Industrial Automation

...: 5 A Maximum switching power 1250 VA (Resistive load) 200 VA (Inductive load (cosφ = 0.4)) 150 W (Resistive load) 45 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/7562/

MY4ZIN-D2 DC24 (S) | OMRON Industrial Automation

...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 250 VAC 3 A (Resistive load) 250 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/7566/

MY4ZN AC100/110 | OMRON Industrial Automation

...DC: 3 A Maximum switching power 660 VA (Resistive load) 176 VA (Inductive load (cosφ = 0.4)) 72 W (Resistive load) 36 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/7567/

MY4ZN AC110/120 | OMRON Industrial Automation

...DC: 3 A Maximum switching power 660 VA (Resistive load) 176 VA (Inductive load (cosφ = 0.4)) 72 W (Resistive load) 36 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/7568/

MY4ZN AC200/220 | OMRON Industrial Automation

...DC: 3 A Maximum switching power 660 VA (Resistive load) 176 VA (Inductive load (cosφ = 0.4)) 72 W (Resistive load) 36 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/7570/

MY4ZN AC24 | OMRON Industrial Automation

...DC: 3 A Maximum switching power 660 VA (Resistive load) 176 VA (Inductive load (cosφ = 0.4)) 72 W (Resistive load) 36 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/7571/

MY4ZN DC100/110 | OMRON Industrial Automation

...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 220 VAC 3 A (Resistive load) 220 VAC 0.8 A (Inductive load (cosφ =...