...vention in an emergency stop situation. Configuration will set the delay for the emergency stop timer circuit. Verification will verify that High Power is disabled without software interven- ...
...OT- 1) oA-10 RW 00: Error 01: Continue operation –Possible 303F 0A 3E8B Communication Watch Dog Timer oA-11 RW 0 to 10000 0.01 (s) Possible 303F 0B 3E8C Action selection at com- munication er...
https://www.fa.omron.com.cn/data_pdf/mnu/i663-e1-02_3g3ax-rx2-ect.pdf
...1 0 Speed Limit Value in Torque Control (Reverse) P040 0 Ad-42 0 Communications Error Detection Timer Setting P044 1 oA-11 1 Operation at Host Communications Error Selection P045 0: Trip oA-1...
https://www.fa.omron.com.cn/data_pdf/mnu/i922-e1-03_3g3rx2_3g3rx.pdf
...pan 0301-2M (0600) (B) User's Manual Cat. No. M066-E1-1 Communications Functions Preset Counter/Timer H8GN I The H8GN supports serial communications specifications, CompoWay/F and Sysway . Th...
...定定时器设置<变量2/常数>,并启动定时器。 在<变量2/常数>时间后,将<变量1>更改为ON或OFF。 同时,它会将TD(i)更改为ON。 timer set TD(*) <变量/ 常数> 为指定定时器设置...
https://www.fa.omron.com.cn/data_pdf/mnu/mx2_rx_i580-cn5-02.pdf
...n/off pulses. •The K3GN indicates the rotational speed in terms of rpm. •A startup compensation timer is used to prevent superfluous output from being produced until the motor reaches a desig...
https://www.fa.omron.com.cn/data_pdf/mnu/n102-e1-05_k3gn.pdf
...hysteresis”,“setting of gate input function”,“voltage fluctuation compensa- tion”,“startup lock timer”and“output ON-delay time”can be changed as required. When the heater ON time is 200ms or ...
https://www.fa.omron.com.cn/data_pdf/mnu/n159-e1-02_k8ac-h.pdf
...Details on Not-stabilized Error Temperature data write timing Temperature data write monitoring timer Temperature data not-refreshed error status ... 5 s 4 s 3 s 2 s 6 s 5 s 4 s 3 s 2 s 6 s 5...
https://www.fa.omron.com.cn/data_pdf/mnu/n227-e1-07_k7tm.pdf
...rror occurs in the power supply If the power supply connection becomes faulty If a CPU watchdog timer error or CPU reset occurs If a major fault level Controller error occurs While the CPU Un...
https://www.fa.omron.com.cn/data_pdf/mnu/nx-had401_had402(safetyprecautions)_inst-5377009-0b.pdf
...rror occurs in the power supply If the power supply connection becomes faulty If a CPU watchdog timer error or CPU reset occurs If a major fault level Controller error occurs While the CPU Un...
...rror occurs in the power supply If the power supply connection becomes faulty If a CPU watchdog timer error or CPU reset occurs If a major fault level Controller error occurs While the CPU Un...
...has been input. Check the connected wiring. Circuit error. Replace the Cam Positioner. Watchdog timer error. p Nothing appear on the display. The ERROR terminal is L. Display circuit error. R...
https://www.fa.omron.com.cn/data_pdf/mnu/o008-e1-04_3f88l-160_162.pdf
................ 5-21 CONTENTS 9 CK3A-series Direct PWM Amplifier User’s Manual (O050) 5-8-2 Delay Timer Subroutine .................................................................................
https://www.fa.omron.com.cn/data_pdf/mnu/o050-e1-05_ck3a-g___l.pdf
...位分配姶受PC控制的単元,即通泣分配在IROOOOO和IROOOO1的輸入点遊来的信号分別控制分配在IROO200和IROO201的輸出点。 OUTPUT或OUTPUTNOT指令与TIMER(定吋器)指令的結合可以控制輸出"ON"或"OFF"一段吋 1旬。...
https://www.fa.omron.com.cn/data_pdf/mnu/oez-zcp97201a_c200hx_c200hg_c200he.pdf
...rred During Operation .............................. 52 3-6 Example of a Ladder Program Using a Timer Instruction ............................... 53 3-6-1 Self-holding Rung .....................
https://www.fa.omron.com.cn/data_pdf/mnu/p122-e1-02_nx1p2_sysmac-se20.pdf
...ring function in the project file. For information on the time monitoring function by using the timer in the project file, refer to 9.3.2. Time Monitoring Function. (3)Errors in the destinati...
https://www.fa.omron.com.cn/data_pdf/mnu/p532-e1-01_fq-cr.pdf
...cations sequence. ●Timeout period setting The following is the settings of the timeout periods (Timer Tr, Tfr, and Tfs) which are set for the sequence. [Communications sequence setting screen...
https://www.fa.omron.com.cn/data_pdf/mnu/p540-e1-01_km50.pdf
...uction G9SP_SerialRcv_Instance SerialRcv The instance of the SerialRcv instruction G9SP_RcvWait_Timer TON Data receive waiting timer. Normally, the SerialRcv instruction is executed ...
https://www.fa.omron.com.cn/data_pdf/mnu/p545-e1-01_g9sp.pdf
...equence settings. ●Timeout period setting The following is the settings of the timeout periods (Timer Tr, Tfr, and Tfs) which are set for the sequence. [Communications sequence setting screen...
https://www.fa.omron.com.cn/data_pdf/mnu/p564-e1-01_v500-r2.pdf
...equence settings. ●Timeout period setting The following is the settings of the timeout periods (Timer Tr, Tfr, and Tfs) which are set for the sequence. [Communications sequence setting screen...
https://www.fa.omron.com.cn/data_pdf/mnu/p565-e1-01_v500-r2.pdf