... IW 0 to 510 -- Output Q 0.0 to 511.7 QW 0 to 510 -- Bit Memory M 0.0 to 2047.7 MW 0 to 2046 -- Timer -- -- T 0 to 511 -- Counter -- -- C 0 to 511 -- Data Block (1 to 4095) (TBR) DBX 0.0 to 6...
https://www.fa.omron.com.cn/data_pdf/mnu/v060-02_nt31_nt631.pdf
...specify the address of the word and the bit position in the word that is referred to Note that, timer (TIM) and counter (CNT) cannot be set for bits or character string words. Using PLC addre...
https://www.fa.omron.com.cn/data_pdf/mnu/v061-e1-06_nt-zjcmx1-v4.pdf
...C. (These areas cannot be accessed through a Host Link connec- tion.) All banks in the EM Area, timer completion flags (TU), counter completion flags (CU), Work Area (WR), task flags (TK), an...
https://www.fa.omron.com.cn/data_pdf/mnu/v064-02_nt31_nt31c_nt631_nt631c.pdf
...Holding area (HR) 101 65 Auxiliary area (AR) 102 66 Link area (LR) 103 67 Work area (WR) 104 68 Timer (TIM) (See note 1.) 200 C8 Counter (CNT) (See note 1.) 201 C9 Data memory area (DM) 300 1...
https://www.fa.omron.com.cn/data_pdf/mnu/v075-e1-15_ns_nsj_nsh.pdf
...Specified Words.................................................................74 3-8 CHANGING TIMER/COUNTER SET VALUES..........................................................................
https://www.fa.omron.com.cn/data_pdf/mnu/v082-e1-10_ns_ext_operation_manu.pdf
...memory area is possible. (*) NT11 PLC Data memory area Internal relay area Auxiliary relay area Timer/counter 10 Direct Connection Function Section 1-5 •This can be used even when the PLC is ...
https://www.fa.omron.com.cn/data_pdf/mnu/v084-e1-01_nt11.pdf
...Series Device Bit Address Word Address Format Counter (Completion Flag) C_FLAG 0-511 ------ DDD Timer (Completion Flag) T_FLAG 0-511 ------ DDD Holding Area H_bit 00.00-99.15 ------ DD.DD Dat...
...es Input Relay X 0-17 ------ OO Output Relay Y 0-15 ------ OO Internal Relay M 0-511 ------ DDD Timer Contact T 0-63 ------ DD Counter Contact C 0-31 ------ DD Data Contact D_bit 0.0-255.F --...
...s Yes Yes AR Auxiliary Area 00000 to 01471 10000 to 11535 Yes Condi- tional Yes Condi- tional T Timer PVs 00000 to 04095 Yes Yes No No C Counter PVs 00000 to 04095 Yes Yes No No DM DM Area 00...
https://www.fa.omron.com.cn/data_pdf/mnu/v119-e1-15_na5-______.pdf
...Series Device Bit Address Word Address Format Counter (Completion Flag) C_FLAG 0-511 ------ DDD Timer (Completion Flag) T_FLAG 0-511 ------ DDD Holding Area H_bit 00.00-99.15 ------ DD.DD Dat...
.......................................................................................3-209 3-7-4 Timer.............................................................................................
https://www.fa.omron.com.cn/data_pdf/mnu/v122-e1-12_nb7w-tw1_b.pdf
...nabled (An asterisk is displayed.) Not selected: Disabled (The asterisk is deleted.) On Refresh Timer Performs backup/restore at every refresh interval. Backup Restore Bit on Performs backup/...
https://www.fa.omron.com.cn/data_pdf/mnu/v228-e1-02_itnc-epx-drm.pdf
...t startup Not lit in the following cases. •When power is not supplied •When there is a watchdog timer (WDT) error 在以下情况下不亮。 •没有电源时 •出现看门狗计时器(WDT)错误时 Lights once when ...
https://www.fa.omron.com.cn/data_pdf/mnu/v780-hmd68-eip-cn_inst-3605037-8a.pdf
...マ) エラーの場合 Not lit in the following cases. •When power is not supplied •When there is a watchdog timer (WDT) error Lights once when processing a communications command or another comma...
https://www.fa.omron.com.cn/data_pdf/mnu/v780-hmd68-eip-jp_inst-3604966-3a.pdf
...P地址时闪烁。 ) Not lit in the following cases. •When power is not supplied •When there is a watchdog timer (WDT) error 在以下情况下不亮。 •没有电源时 •出现看门狗计时器(WDT)错误时 Lights onc...
https://www.fa.omron.com.cn/data_pdf/mnu/v780-hmd68-etn-cn-s_inst-2883780-6a.pdf
...マ) エラーの場合 Not lit in the following cases. •When power is not supplied •When there is a watchdog timer (WDT) error Lights once when processing a communications command or another comma...
https://www.fa.omron.com.cn/data_pdf/mnu/v780-hmd68-etn-jp-s_inst-2883788-1a.pdf
...t the Master The PROFIBUS Master monitors data transmission of the slaves with the Data-Control-Timer. A separate control timer is used for each slave. This timer expires if...
https://www.fa.omron.com.cn/data_pdf/mnu/w05e-en-01_cx-profibus_opermanual.pdf
... I/O Unit A dedicated Unit, such as a Position Control Unit, High-Speed Counter Unit, or Analog Timer Unit, which is designed for a special purpose. Glossary 145 speed coefficient An IR area ...
https://www.fa.omron.com.cn/data_pdf/mnu/w137-e1-04_c200h_nc111.pdf
...f the Completion Flags of the specified number of timers/ counters, starting from the specified timer/counter. Command Format @ RG X101 X100 FCS CR * Beginning timer/counter X103 X10...
https://www.fa.omron.com.cn/data_pdf/mnu/w143-07_c200h-lk_c500-lk_3g2a6-lk.pdf
... PC (see note) and remount it, making sure the connecting terminals are secure. A WDT (watchdog timer) error has occurred in the ID Sensor Unit. Turn OFF/ON/OFF the Special I/O Unit restart f...
https://www.fa.omron.com.cn/data_pdf/mnu/w153-e1-04_c200h-ids.pdf