...Control output 1 Relay output Control output 2 None Relay output 1 point SPDT, 10 A at 250 VAC, cos φ= 1 (resistive load) Setting method Analog Indication method No indication Hysteresis Appr...
...Control output 1 Relay output Control output 2 None Relay output 1 point SPDT, 10 A at 250 VAC, cos φ= 1 (resistive load) Setting method Analog Indication method No indication Hysteresis Appr...
...trol output 1 Relay output Control output 2 None Relay output 1 point SPST-NO, 10 A at 250 VAC, cos φ= 1 (resistive load) Setting method Digital setting using front panel keys Indication meth...
...trol output 1 Relay output Control output 2 None Relay output 1 point SPST-NO, 10 A at 250 VAC, cos φ= 1 (resistive load) Setting method Digital setting using front panel keys Indication meth...
...trol output 1 Relay output Control output 2 None Relay output 1 point SPST-NO, 10 A at 250 VAC, cos φ= 1 (resistive load) Setting method Digital setting using front panel keys Indication meth...
...ce Approx. 4.7 kΩ) Control output Contact output SPST-NO 3 A at 250 VAC/30 VDC, resistive load (cos phi=1) Minimum applicable load: 10 mA at 5 VDC (failure level:P reference value) Solid-stat...
...ce Approx. 4.7 kΩ) Control output Contact output SPST-NO 3 A at 250 VAC/30 VDC, resistive load (cos phi=1) Minimum applicable load: 10 mA at 5 VDC (failure level:P reference value) Solid-stat...
....7 kΩ) Control output Contact output 2 stages of SPST-NO 3 A at 250 VAC/30 VDC, resistive load (cos phi=1) Minimum applicable load: 10 mA at 5 VDC (failure level:P reference value) Solid-stat...
....7 kΩ) Control output Contact output 2 stages of SPST-NO 3 A at 250 VAC/30 VDC, resistive load (cos phi=1) Minimum applicable load: 10 mA at 5 VDC (failure level:P reference value) Solid-stat...
...25 A (NO contact: Inductive load (cosφ = 0.4)) 220 VAC 1 A (Twin contacts (NC): Resistive load (cos φ= 1)) 30 VDC 25 A (NO contact: Resistive load) Terminal structure Screw terminal Item list...
...25 A (NO contact: Inductive load (cosφ = 0.4)) 220 VAC 1 A (Twin contacts (NC): Resistive load (cos φ= 1)) 30 VDC 25 A (NO contact: Resistive load) Terminal structure PCB terminal Item list o...
...25 A (NO contact: Inductive load (cosφ = 0.4)) 220 VAC 1 A (Twin contacts (NO): Resistive load (cos φ= 1)) 30 VDC 25 A (NO contact: Resistive load) Terminal structure PCB terminal Item list o...
...25 A (NO contact: Inductive load (cosφ = 0.4)) 220 VAC 1 A (Twin contacts (NO): Resistive load (cos φ= 1)) 30 VDC 25 A (NO contact: Resistive load) Terminal structure PCB terminal Item list o...
...0, 110, 220 V DC 24, 100, 110, 120, 200, 220, 230, 240V AC MKS1T, MKS2T: AC 250V 15A(NO)/5A(NC) cos(phi) = 1.0 MKS1XT: DC 220V 10A DC 220 5A L/R = 7ms DC-13 220V 0.4A MKS2XT: DC 220V 5A(NO)/2...
...Example of the Switching Section (Contacts) Specifications Load Resistance load Inductive load (cos Φ = 0.4, L/R = 7 ms) Rated load 220 VAC 5 A 24 VDC 5 A 220 VAC 2 A 24 VDC 2 A Rated carry c...
...heck whether the specifications are suitable.) Type Load 4 poles Resistive load Inductive load (cos Φ = 0.4, L/R = 7 ms) Contact Type Single Contact material AgCdO Rated load 110 VAC 10 A 24 ...
...act Rating (Check whether the specifications are suitable.) Load Resistive load Inductive load (cos Φ = 0.4, L/R = 7 ms) Rated load 220 VAC 5 A 24 VDC 5 A 220 VAC 2 A 24 VDC 2 A Rated carry c...
...tored in the inductive load. Example: MY2 General-purpose Relays Resistive load Inductive load (cos Φ = 0.4, L/R = 7 ms) Rated load 220 VAC, 5 A 24 VDC, 5 A 220 VAC, 2 A 24 VDC, 2 A When AC i...
...act Rating (Check whether the specifications are suitable.) Load Resistive load Inductive load (cos Φ = 0.4, L/R = 7 ms) Rated load 220 VAC 3 A 24 VDC 3 A 220 VAC 0.8 A 24 VDC 1.5 A Rated car...
...heck whether the specifications are suitable.) Type Load 2 poles Resistive load Inductive load (cos Φ = 0.4, L/R = 7 ms) Contact type Single Contact material AgCdO Rated load 110 VAC 10 A 24 ...