CJ1W-TC CJ Series Temperature Control Unit/Lineup ...

...outputs 5 V 24 V CJ1 Special I/O Units Temperature Control Units 4 loops Thermocouple input (R, S, K, J, T, B, L) Open collector NPN outputs (pulses) 2 0.25 - CJ1W-TC001 * UC1, N, L, CE 4 loo...

https://www.ia.omron.com/products/family/1438/lineup.html

DRT2-ROS16 Remote I/O Terminal with Relay Outputs/...

...5 Hz, 0.7-mm double amplitude, 80 min each in the X, Y, and Z directions Shock resistance 100 m/s 2 Dielectric strength 500 VAC (between isolated circuits) Insulation resistance 20 MΩ min. Am...

https://www.ia.omron.com/products/family/1440/specification.html

D4NS, D4NS-SK Safety-door Switch/Lineup | OMRON In...

...2 D4NS-2CF-SJ * M20 D4NS-4CF-SJ * 3NC G1/2 D4NS-2DF-SJ * M20 D4NS-4DF-SJ * * Models with Korean S-mark certification. Operation Keys Type Model Horizontal mounting D4DS-K1 Vertical mounting D...

https://www.ia.omron.com/products/family/1465/lineup.html

S8T-DCBU-02 Buffer Block/Specifications | OMRON In...

..., 0.375-mm single amplitude for 2 h each in X, Y, and Z directions Shock resistance *5 *6 150 m/s 2 , 3 times each in ±X, ±Y, and ±Z directions EMI Conducted Emission *5 Conforms to EN61204-3...

https://www.ia.omron.com/products/family/1466/specification.html

E4PA-N Ultrasonic Displacement Sensor/Specificatio...

...double amplitude for 2 hours each in X, Y, and Z directions Shock resistance Destruction: 300 m/s 2 three times each in X, Y, and Z directions Connection method 5-conductor connector Degree o...

https://www.ia.omron.com/products/family/1467/specification.html

DRT2-[]D16TA(-1) Transistor Remote I/O Terminals w...

...2 kV (power line) Vibration resistance 10 to 60 Hz, 0.7-mm double amplitude, 60 to 150 Hz, 50 m/s 2 for 80 min each in the X, Y, and Z directions Shock resistance 150 m/s 2 (3 times ...

https://www.ia.omron.com/products/family/1486/specification.html

D4N Safety Limit Switch/Specifications | OMRON Ind...

...50 VAC) *3 300,000 operations min. (10 A resistive load at 250 VAC) Operating speed 1 to 500 mm/s (D4N-1120) Operating frequency 30 operations/minute max. Contact resistance 25 mΩ max. Minimu...

https://www.ia.omron.com/products/family/1497/specification.html

G3ZA Multi-channel Power Controller/Specifications...

...primary and secondary Vibration resistance Vibration frequency: 10 to 55 Hz, acceleration: 50 m/s 2 in X, Y, and Z directions Shock resistance 300 m/s 2 three times each in six direc...

https://www.ia.omron.com/products/family/1511/specification.html

ES1B Infrared Thermosensor/Specifications | OMRON ...

... or condensation) Allowable ambient humidity 35% to 85% Vibration resistance (destruction) 98 m/s 2 for 2 hours each in X, Y, and Z directions at 10 to 55 Hz Shock resistance (destruction) 30...

https://www.ia.omron.com/products/family/1516/specification.html

E32 Series Fiber Sensors | OMRON Industrial Automa...

...MRON Industrial Automation Item list of E32 Series Fiber Sensors Fiber Sensors E32 Series OMRON's Fiber Sensors continue to support an increasing range of applications. Displaying individual ...

https://www.ia.omron.com/products/family/1532/itemlist/

CJ1W-FLN22 CJ-series FL-net Unit/Specifications | ...

...stance Conforms to JIS 0040. 10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz, acceleration: 9.8 m/s 2 in X, Y, and Z directions for 80 minutes each (Time coefficient; 8 minutes × coefficient fa...

https://www.ia.omron.com/products/family/1549/specification.html

DST1 Series Safety I/O Terminals/Specifications | ...

...s to IEC61131-2. Vibration resistance 10 to 57 Hz: 0.35-mm single amplitude, 57 to 150 Hz: 50 m/s 2 Shock resistance 150 m/s 2 , 11 ms 100 m/s 2 , 11 ms 150 m/s 2 ,...

https://www.ia.omron.com/products/family/1626/specification.html

CJ1W-IDP01 CJ-series Quick-response Input Units/Sp...

...se "Jxx" as the device name. With quick-response inputs, pulse inputs shorter than the CPU Unit's cycle time can be read by the CPU Unit. The pulse width (ON time) that can be read by the Qui...

https://www.ia.omron.com/products/family/1643/specification.html

CJ1W-PTS CJ-series Process Analog I/O Unit/Lineup ...

...uple Input Units) 2 inputs Set sepa- rately for each input Thermo- couple: B, E, J, K, L, N, R, S, T, U, WRe5- 26, PLII DC voltage: ± 100 mV Conver- sion speed: 10 ms/ 2 inputs, Resolu- tion:...

https://www.ia.omron.com/products/family/1644/lineup.html

CJ1W-PDC15 CJ-series Process Analog I/O Unit/Lineu...

...A, 4 to 20 mA Conver- sion speed: 10 ms/ 2 inputs Resolu- tion: 1/64,000 Accuracy: ± 0.05% of F.S. Re- movable terminal block 1 0.18 0.09 * CJ1W-PDC15 UC1, CE * This is for an external power ...

https://www.ia.omron.com/products/family/1646/lineup.html

CS1W-PTS SYSMAC CS-series Process Analog I/O Units...

...ed- type Thermo- couple Input Units 4 inputs Set separately for each input B, E, J, K, L, N, R, S, T, U, WRe5-26, PLII, ± 100 mV 20 ms/ 4 inputs, 10 ms/ 2 inputs Removable terminal block 1 0....

https://www.ia.omron.com/products/family/1664/lineup.html

CS1W-FLN22 CS-series FL-net Unit/Specifications | ...

...stance Conforms to JIS 0040. 10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz, acceleration: 9.8 m/s 2 in X, Y, and Z directions for 80 minutes each (Time coefficient; 8 minutes × coefficient fa...

https://www.ia.omron.com/products/family/1683/specification.html

E52-THE5A / 6D / 6F Temperature Sensor (Thermistor...

...changeable thermistor Class JIS class 1 Protective tubing material SUS304 Time constant 8 to 15 s in still water Dissipation factor 2.4 to 2.8 mW/°C in still air Lead wire heat resistive temp...

https://www.ia.omron.com/products/family/1743/specification.html

S8M Digital Multicircuit Protector/Specifications ...

...put Startup sequence Can be enabled/disabled for each branch output, setting range: 0.0 to 99.9 s in 0.1-s units. Shutdown sequence Can be enabled/disabled for each branch output, se...

https://www.ia.omron.com/products/family/1768/specification.html

K7L-U[] / UD[][] Liquid Leakage Sensor Amplifiers ...

...1 W max. Response time Operate: 800 ms max. Release: 800 ms max. Startup time after power ON: 2 s max. Weight Approx. 14 g Ratings Rated power supply voltage 12 to 24 VDC (Allowable voltage f...

https://www.ia.omron.com/products/family/1819/specification.html