...functions Before using EDM, verify that the F3SG-R goes to the Lockout state when the F3SG-R is wired in such a way that the specified voltage is applied directly to the RESET input of the re...
...stallation Manual Performance Response time Normal mode ON to OFF Optical synchronization: 8 ms Wired synchronization: 10 ms OFF to ON Optical synchronization: 40 ms Wired synchroniz...
...ations. Safety Standards *1. The indicator of the emitter is illuminated only in the case the Wired Synchronizati- on is enabled and is off in the case the Optical Synchronization is enable...
https://www.fa.omron.com.cn/data_pdf/mnu/f3sg-_pg_series_inst-2865475-2d.pdf
...fter setting with DIP-SW, verify that the F3SG-RA goes to the Lockout state when the F3SG-RA is wired in such a way that the specified voltage is applied directly to the RESET input of the re...
https://www.fa.omron.com.cn/data_pdf/mnu/f3sg-_raseries(quickinstallationmanual)_inst-7999687-9h.pdf
...nctions Before using EDM, verify that the F3SG-RR goes to the Lockout state when the F3SG-RR is wired in such a way that the specified voltage is applied directly to the RESET input of the re...
https://www.fa.omron.com.cn/data_pdf/mnu/f3sg-_rr_seies(quickinstallationmanual)_inst-9308038-0d.pdf
...rating Range Selection or adjusting the distances from adja- cent safety light curtains. In the Wired Synchronization, mutual interference is prevented in up to 3 sets, using interference lig...
https://www.fa.omron.com.cn/data_pdf/mnu/f3sg-_sr-kseries_inst-2871537-9a.pdf
...4 5 7 8 9 6 LED Indicators *1. The indicator of the emitter is illuminated only in the case the Wired Synchronization is enabled and is off in the case the Optical Synchronization is enabled....
https://www.fa.omron.com.cn/data_pdf/mnu/f3sg-_sr_-kseries_inst-2865458-2d.pdf
...Standards LED Indicators *1. The indicator of the emitter is illuminated only in the case the Wired Synchronization is enabled and is off in the case the Optical Synchronization is enabled....
https://www.fa.omron.com.cn/data_pdf/mnu/f3sg-_sr_series_inst-5605401-9f.pdf
... in your site. Make sure to turn the power off the F3SG-SR before replacing the End Cap. In the Wired Synchro- nization *, selecting a scan code is unnecessary. *In the Wired Synchro...
https://www.fa.omron.com.cn/data_pdf/mnu/f3sg-_srseries(quickinstallationmanual)_inst-5605409-4c.pdf
...owing items must also be verified. □The outputs of the F3SJ-A-01TS and the machine are properly wired. □The total number of times that the control relays/contactors have switched is significa...
...llowing items must also be verified. □The outputs of the F3SJ-A-TS and the machine are properly wired. □The total number of times that the control relays/contactors have switched is significa...
... following items must also be verified. □The outputs of the F3SJ-A and the machine are properly wired. □The total number of times that the control relays/contactors have switched is significa...
...following items must also be verified. □The outputs of the F3SJ-AM and the machine are properly wired. □The total number of times that the control relays/contactors have switched is significa...
https://www.fa.omron.com.cn/data_pdf/mnu/f3sj-am_p___series_inst-3126477-9b.pdf
...eries connection allows them to be used as a safety light curtain, requiring only one set to be wired to a controller and preventing mutual interference. If any one set of series-connected F3...
...eries connection allows them to be used as a safety light curtain, requiring only one set to be wired to a controller and preventing mutual interference. If any one set of series-connected F3...
...eries connection allows them to be used as a safety light curtain, requiring only one set to be wired to a controller and preventing mutual interference. If any one set of series-connected F3...
...eries connection allows them to be used as a safety light curtain, requiring only one set to be wired to a controller and preventing mutual interference. If any one set of series-connected F3...
...ld level A B C Cause of error The Interlock selection input line or the reset input line is not wired correctly or became open. Relay contact is welded. Releasing time of the relay takes too ...
https://www.fa.omron.com.cn/data_pdf/mnu/f3sn-b_scee-717.pdf
...h each in X,Y and Z directions. 500m/s2,3times each in X,Y and Z directions. F3W-D052A (P)* Pre-wired F3W-D052B (P)* Connector-mounted cord (M12) SW1 Receiver Emitter Receiver Main circuit (...
https://www.fa.omron.com.cn/data_pdf/mnu/f3w-d052a__-d052b__inst-9307938-2b.pdf
...h each in X,Y and Z directions. 500m/s2,3times each in X,Y and Z directions. F3W-D052C (P)* Pre-wired F3W-D052D (P)* Connector-mounted cord (M12) SW1 Receiver Emitter ON 123456 ON 123456 ON 1...
https://www.fa.omron.com.cn/data_pdf/mnu/f3w-d052c__-d052d__inst-9309466-7b.pdf