Primary Contents

IA Global Search Results

Select Country in

Site Search Product Search IA Global Search
Results 9061 - 9080 of 25803
PDF[N228-E1-06] K7TM Data Sheet

...culates a resistance value by measuring the voltage at both ends of the heater and its current, so it can measure the resistance value of even the live heater. In addition, by collecting the ...

https://www.fa.omron.co.jp/data_pdf/cat/k7tm_n228-e1_3_3_csm1115712.pdf

PDF[N229-E1-03] K7TM Catalog

...ate of change of the heater resistance value and monitor the state and tendency of each heater, so it is possible to determine when replacement is necessary, so it is unplanned while...

https://www.fa.omron.co.jp/data_pdf/cat/k7tm_n229-e1_2_2_csm1118653.pdf

PDF[N179-E1-03] K8AK-AS Catalog

...to 100% of the rated current (i.e., 10 to 100 A). Pass the conductors through the CT five times so that at least 10 A of current flows. The input current to the K8AK will be 25 A (i.e., 5 A x...

https://www.fa.omron.co.jp/data_pdf/cat/k8ak-as_n179-e1_4_7_csm1020909.pdf

PDF[N180-E1-04] K8AK-AW Catalog

...to 100% of the rated current (i.e., 10 to 100 A). Pass the conductors through the CT five times so that at least 10 A of current flows. The input current to the K8AK will be 25 A (i.e., 5 A x...

https://www.fa.omron.co.jp/data_pdf/cat/k8ak-aw_n180-e1_4_8_csm1020910.pdf

PDF[N188-E1-03] K8AK-LS Catalog

...ear radio wave receivers. 13.Install an external switch or circuit breaker and label it clearly so that the operator can quickly turn OFF the power supply. 14.Make sure the indicators operate...

https://www.fa.omron.co.jp/data_pdf/cat/k8ak-ls_n188-e1_4_9_csm1020918.pdf

PDF[N186-E1-03] K8AK-PA Catalog

...oad phase loss cannot be detected during operation. 6. Phase loss is detected based on voltage, so phase loss cannot be detected on the load side. Calculating the Asymmetry Operating Voltage ...

https://www.fa.omron.co.jp/data_pdf/cat/k8ak-pa_n186-e1_3_7_csm1020916.pdf

PDF[N183-E1-03] K8AK-PH Catalog

...ear radio wave receivers. 12.Install an external switch or circuit breaker and label it clearly so that the operator can quickly turn OFF the power supply. 13.Make sure the indicators operate...

https://www.fa.omron.co.jp/data_pdf/cat/k8ak-ph_n183-e1_3_6_csm1020913.pdf

PDF[N185-E1-03] K8AK-PM Catalog

...et value and measure the time until the Unit operates. Operating Time Adjust the slide resistor so that the voltage applied to the K8AK terminals is 120% of the set value (for overvoltage det...

https://www.fa.omron.co.jp/data_pdf/cat/k8ak-pm_n185-e1_3_7_csm1020915.pdf

PDF[N184-E1-03] K8AK-PW Catalog

...et value and measure the time until the Unit operates. Operating Time Adjust the slide resistor so that the voltage applied to the K8AK terminals is 120% of the overvoltage set value or 80% o...

https://www.fa.omron.co.jp/data_pdf/cat/k8ak-pw_n184-e1_3_8_csm1020914.pdf

PDF[N187-E1-03] K8AK-TH Catalog

...ear radio wave receivers. 18.Install an external switch or circuit breaker and label it clearly so that the operator can quickly turn OFF the power supply. 19.When cleaning the product, do no...

https://www.fa.omron.co.jp/data_pdf/cat/k8ak-th_n187-e1_4_7_csm1020917.pdf

PDF[N189-E1-03] K8AK-TS/PT Data Sheet

... value for which the alarm indicator (TS_ALM) lights. The contact outputs switch simultaneously so that you can confirm operation. Note: Refer to the timing charts for the operating methods f...

https://www.fa.omron.co.jp/data_pdf/cat/k8ak-ts_pt_n189-e1_3_7_csm1020919.pdf

PDF[N181-E1-03] K8AK-VS Data Sheet

...ear radio wave receivers. 13.Install an external switch or circuit breaker and label it clearly so that the operator can quickly turn OFF the power supply. 14.Make sure the indicators operate...

https://www.fa.omron.co.jp/data_pdf/cat/k8ak-vs_n181-e1_2_9_csm1020911.pdf

PDF[N182-E1-03] K8AK-VW Catalog

...ear radio wave receivers. 13.Install an external switch or circuit breaker and label it clearly so that the operator can quickly turn OFF the power supply. 14.Make sure the indicators operate...

https://www.fa.omron.co.jp/data_pdf/cat/k8ak-vw_n182-e1_2_8_csm1020912.pdf

PDF[N193-E1-02] K8DS-PA Catalog

...y switch setting. Example: K8DS-PA1 with Rotary Switch Set to 200 V The rated input is 200 VAC, so the setting range is 4 to 44 V. If the setting (ASY. knob) is at 10%, the asymmetry operatio...

https://www.fa.omron.co.jp/data_pdf/cat/k8ds-pa_n193-e1_2_5_csm1020923.pdf

PDF[N190-E1-02] K8DS-PH Data Sheet

...ear radio wave receivers. 12.Install an external switch or circuit breaker and label it clearly so that the operator can quickly turn OFF the power supply. 13.Make sure the indicators operate...

https://www.fa.omron.co.jp/data_pdf/cat/k8ds-ph_n190-e1_2_4_csm1020920.pdf

PDF[N192-E1-02] K8DS-PM Catalog

...et value and measure the time until the Unit operates. Operating Time Adjust the slide resistor so that the voltage applied to the K8DS terminals is 120% of the set value for overvoltage dete...

https://www.fa.omron.co.jp/data_pdf/cat/k8ds-pm_n192-e1_2_5_csm1020922.pdf

PDF[N191-E1-02] K8DS-PU Catalog

...nd measure the time required for the Relay to operate. Operating Time Adjust the slide resistor so that the voltage applied to the K8DS terminals is 80% of the set value when the auxiliary re...

https://www.fa.omron.co.jp/data_pdf/cat/k8ds-pu_n191-e1_2_6_csm1020921.pdf

PDF[N194-E1-03] K8DS-PZ Catalog

...y switch setting. Example: K8DS-PZ1 with Rotary Switch Set to 200 V The rated input is 200 VAC, so the setting range is 10 to 44 V. If you set the setting knob (ASY.) to 10%, the asymmetry op...

https://www.fa.omron.co.jp/data_pdf/cat/k8ds-pz_n194-e1_2_6_csm1020924.pdf

PDF[N201-E1-02] K8DT-AS Data Sheet

...to 100% of the rated current (i.e., 10 to 100 A). Pass the conductors through the CT five times so that at least 10 A of current flows. The input current to the K8DT will be 25 A (i.e., 5 A x...

https://www.fa.omron.co.jp/data_pdf/cat/k8dt-as_n201-e1_1_9_csm1050137.pdf

PDF[N202-E1-02] K8DT-AW Data Sheet

...to 100% of the rated current (i.e., 10 to 100 A). Pass the conductors through the CT five times so that at least 10 A of current flows. The input current to the K8DT will be 25 A (i.e., 5 A x...

https://www.fa.omron.co.jp/data_pdf/cat/k8dt-aw_n202-e1_2_2_csm1050138.pdf

Results 9061 - 9080 of 25803

Select Country in