Site Search | Product Search | IA Global Search |
... Note Green Red Yellow Supply voltage On Off Off 0V 0V Actuated On Off On 24 V 24 V Actuated in limit area On Off Flashes (1Hz) 24 V pulsed 24 V The safety door switch must be adjusted before...
https://www.fa.omron.co.jp/data_pdf/mnu/d41d_inst-5673883-0c.pdf
...ines or high-voltage lines. • Do not pull on the cables or bend the cables beyond their natural limit. Doing either of these may break the cables. • Fail-safe measures must be taken by the cu...
https://www.fa.omron.co.jp/data_pdf/mnu/drt2-_d16ml(x)(-1)_inst-1632751-9b.pdf
...ications connector cable. (7) Do not pull on the cables or bend the cables beyond their natural limit. Doing so may break the cables. (8) Double-check all the wiring before turning on the pow...
https://www.fa.omron.co.jp/data_pdf/mnu/drt2-_d16sl__inst-1156222-6c.pdf
...output (photoelectric or proximity sensor) 青︵黒︶ 茶︵白︶ one com Black (white) 2-wire sensor (e.g., limit switch) Brown (red) Blue (black) 3-wire sensor with NPN output (photoelectric or ...
https://www.fa.omron.co.jp/data_pdf/mnu/drt2-_d16sl__inst-3665971-2a.pdf
... lines or high-voltage lines. Do not pull on the cables or bend the cables beyond their natural limit. Doing either of these may break the cables. Fail-safe measures must be taken by the cust...
https://www.fa.omron.co.jp/data_pdf/mnu/drt2-_d16ta(-1)_inst-0675249-1c.pdf
...ines or high-voltage lines. ・ Do not pull on the cables or bend the cables beyond their natural limit. Doing either of these may break the cables. ・ Fail-safe measures must be taken by the ...
https://www.fa.omron.co.jp/data_pdf/mnu/drt2-_d32(-1)_inst-0675250-5c.pdf
...ines or high-voltage lines. • Do not pull on the cables or bend the cables beyond their natural limit. Doing either of these may break the cables. • Fail-safe measures must be taken by the cu...
https://www.fa.omron.co.jp/data_pdf/mnu/drt2-_d32b(v)(-1)_inst-1632665-2b.pdf
...V G G0 G1 G15 G + − Black(white) Blue(black) 2-wire Sensor 3-wire Sensor with NPN output (e.g.. limit switch) (photoelectric or proximity switch) Brawn(red) Brawn(white) Blue(bla...
https://www.fa.omron.co.jp/data_pdf/mnu/drt2-_d32sl__inst-3665972-0a.pdf
.... Not doing so may result in serious accidents. 1. Emergency stop circuits, interlock circuits, limit circuits, and similar safety measures must be provided in external control circuits. 2. R...
https://www.fa.omron.co.jp/data_pdf/mnu/drt2-_d32sl__inst-3665982-8a1.pdf
...ion. Not doing so may result in serious accidents. Emergency stop circuits, interlock circuits, limit circuits, and similar safety measures must be provided in external control circuits. The ...
https://www.fa.omron.co.jp/data_pdf/mnu/drt2-ad04_-da02_inst-1617231-0f.pdf
...n. Not doing so may result in serious accidents. 1.Emergency stop circuits, interlock circuits, limit circuits, and similar safety measures must be provided in external control circuits. 2.Re...
https://www.fa.omron.co.jp/data_pdf/mnu/drt2-clseries_inst-0631713-2f.pdf
...)(Black)(White) Broun Blue (White) (Black) Broun Blue Black (Red)(Black)(White) 2-wired sensor (limit switch) NPN output 3-wired sensor (photoelectric or proximity sensor) 2-wired sensor...
https://www.fa.omron.co.jp/data_pdf/mnu/drt2-id16s(-1)_inst-0631626-8d_.pdf
...ted communications cable. (8) Do not pull on the cables or bend the cables beyond their natural limit. Doing so may break the cables. (9) Double-check all the wiring before turning on the pow...
https://www.fa.omron.co.jp/data_pdf/mnu/drt2-ros16_inst-0631634-9f.pdf
...iven in the following table. Controlling Devices Emergency stop switch Door interlocking switch Limit switch Safety sensor Relay with forcibly guided contacts Contactor Other devices • Discon...
https://www.fa.omron.co.jp/data_pdf/mnu/dst1-id_m(r)d_xd__(__)sl-1_inst-1625834-7i.pdf
...leted 10 to 30 VDC Load Orange *1 Control Output 2 The sensitivity is adjusted to the detection limit of 3750, which maximizes the change with the detector. The threshold is 3750. Workpiece i...
https://www.fa.omron.co.jp/data_pdf/mnu/e2nc-ea__series_inst-3128438-9c.pdf
...tion Transition Charts Whe be di Special functions Linear output correction p. 85 Display digit limit p. 102 Error Output Zero reset memory erout p. 98 p. 95 When all is selected, all special...
...ow Light Intensity) (Reserved) Error (Insufficient Light Intensity) Error (Distance Upper/Lower Limit Value) Warning 13 Index Device ID *3644117-2A* PD2 Index 0 1 2. Process data bit PD0 PD1 ...
https://www.fa.omron.co.jp/data_pdf/mnu/e3as-hf6000_m__(indexlist)_inst-3644117-2a.pdf
...ng value Current scaling Low (4 mA) 50 Current scaling High (20 mA) 6000 20.5 mA (Current upper limit value) 20 mA ON Emission OFF Emission Current Laser OFF * About 800 ms is required until ...
https://www.fa.omron.co.jp/data_pdf/mnu/e3as-hf6000_m_inst-3669664-2c.pdf
... EEPROM memory to save the configuration information. If the memory rewritable time exceeds its limit (100,000 times), the memory error will be displayed and the amplifier unit needs to be re...
https://www.fa.omron.co.jp/data_pdf/mnu/e3c-lda__nseries_inst-5710590-3a.pdf
...0 1. Select [Setting Mode] - [OUT1 Mode] - [Area Detection Mode]. [rst] rst The lower threshold limit is -1999. Cancel ● Area Detection Mode Initialize all settings to the factory-set default...
https://www.fa.omron.co.jp/data_pdf/mnu/e3nc-la__series_inst-4013143-9h.pdf