Primary Contents

IA Global Search Results

Select Country in

Site Search Product Search IA Global Search
Results 1021 - 1040 of 1148
PDF[Z377-E1-06] MX-Z2000H series Fiber Laser Marker U...

...2 3 4 5 6 7  RD (RXD) SD (TXD)    SG (GND) 8 9 10 11 12 13 14 15  RDB () RDA () SDB ( SDA (    (Not used) Enters data from the external device. Outputs data from the controller....

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z377-e1-06_mx-z2000h.pdf

PDF[Z423-E1-02] FZ5 Series Vision System Hardware Set...

...is used in Sensor Controller. Pin No. 9 8 7 6 1 2 3 4 5 6 7 8 9 Signal name SDB(+) SD/SDA(-) RD/RDA(-) RDB(+) NC NC NC NC GND Function For RS-422 For RS-232C/RS-422 For RS-232C/RS-422 For RS-...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z423-e1-02_fz5.pdf

PDF[1284053-0D] ZFX-XPT□B プログラマブルコントローラ/プログラマブルターミナル接...

...ケーブル被覆部:耐熱塩化ビニル (PVC) NC 3 3 NC 最小曲げ半径 NC 4 NC 付属品 RDB(+) 4 5 6 RDA(-) RDA(-) SDB(+) 7 7 NC SDA(-) 8 9 10 シェル 8 9 RDB(+) SG(GND) シェル FG ご使用に際...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/zfx-xpt_b_inst-1284053-0d.pdf

PDFCSM_E5AN-HT_E5EN-HT_DS_E_1_14 1

...fer output (E5@N-@F@) *3.Orders will not be accepted after March 31, 2018. Potentiometer *3 RDB RDA SG SDB SDA 4 to 20 mA DC (Load: 600 X max.) 4 to 20 mA DC 1 2 3 4 5 6 7 8 9 10 21 22 23 24 ...

https://www.fa.omron.com.cn/data_pdf/closed/cat/e5an-ht_e5en-ht_ds_e_1_14_csm2669.pdf

PDF●警告表示の意味 警告 注意 ●警告表示 警告 注意 お断りなく仕様などを変更することがありますので...

...圧で使用してください。 ●RS-422/485を接続時は、必ず極性を確認の上結線してください。 相手機器によっては、略称SDA/SDB、RDA/RDBと信号の+/-が逆になるものがあります。 ●RS-422/485で使用する場合は...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/cj1w-cif21(safetyprecautions)_inst-1617140-3c.pdf

PDFomRon 形D4GL・一・SKlO-・-LK 0686955・OC

...usuracEie`10npregilidrclllrlsuofusTztosvamento '蒜耀1瓢蕊㍑;:重=:,:㍑瓢識罐霊㌫麟蒜㍑罐o。 「tpaTato ・Pe岬lant◎ngu轟rda}a!mamtenzlone,lecendizionidiusoedidettag【ide}1'intern】ttoredausareel...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/d4gl-sk10-lk_inst-0686955-0c.pdf

PDFE5AK-T Digital Controller INSTRUCTION MANUAL

...5AK-T□01□E5AK-T□02□E5AK-T□03□ RS-232C RS-422 RS-485 18 19 20 SD RD SG 18 19 20 18 20 19 SDA SDB RDA RDB SG 31 32 A B A B 20 19 31 32 + + - ●OPTION2●OPTION3 Transfer output 29 30 4-20mA L ...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/e5ak-t_inst-0691369-0b.pdf

PDFMAIN SPECIFICATIONS - Supply voltage AC100-240V (-...

...B□E5AK-□01□E5AK-□02□E5AK-□03□ RS-232C RS-422 RS-485 18 19 20 SD RD SG 18 19 20 18 20 19 SDA SDB RDA RDB SG 31 32 A B A B 20 19 31 32 + + - ●OPTION2●OPTION3 Transfer output 29 30 4-20mA L ...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/e5ak_inst-0682534-0b.pdf

PDFկ⬉⬉य़ 100̚240 VACˈ50/60 Hz៪㗙 24 VACˈ50/60 Hz/24 VD...

...ᕫՓ⫼ϡᕫՓ⫼ + +− B + V mA −− B A ϡᕫՓ⫼ 14 15 16 11 12 RS-232C RS-485 RS-422 SD 11 RD 12 SG 13 RDB 11 RDA 12 SG 13 SDB 21 SDA 22 B(+) 11 A(−) 12 13 B(+) 21 A(−) 22 21 22 25 26 27 28 EV4 EV3 21 22 2...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/e5an-ht_inst-2152947-2a_discon.pdf

PDFPower supply voltage 100 to 240 VAC, 50/60 Hz or

... 14 15 16 DO NOT USE DO NOT USE DO NOT USE 11 12 RS-232C RS-485 RS-422 SD 11 RD 12 SG 13 RDB 11 RDA 12 SG 13 SDB 21 SDA 22 B(+) 11 A(−) 12 13 B(+) 21 A(−) 22 21 22 25 26 27 28 EV4 EV3 21 22 2...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/e5an-ht_inst-2153002-0a.pdf

PDFMINSTALLATION •Mounting Panels•Mounting the Contro...

...Event input1/2Transfer output RS-232C RS-422 RS-485 18 19 20 SD RD SG 18 19 20 18 20 19 SDA SDB RDA RDB SG 21 22 A B A B 20 19 21 22 22 21 4-20mA L + - E5EK-T□B□E5EK-T□01□E5EK-T□02□E5EK-...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/e5ek-t_inst-0646040-7b.pdf

PDFMCABLE CONNECTIONS •RS-232C interface: E5EK-M01M

...Event input1/2Transfer output RS-232C RS-422 RS-485 18 19 20 SD RD SG 18 19 20 18 20 19 SDA SDB RDA RDB SG 21 22 A B A B 20 19 21 22 22 21 4-20mA L + - E5EK-□B□E5EK-□01□E5EK-□02□E5EK-□03...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/e5ek_inst-0682536-7b.pdf

PDFINSTRUCTION MANUAL (SETUP) FZ3-30_-10/FZ3-35_-10/F...

...onal computer or PLC being connected. Pin No. 1 2 3 4 5 6 7 8 9 Signal name SDB(+) SD/SDA(-) RD/RDA(-) RDB(+) NC NC NC NC GND Function For RS-422 For RS-232C/RS-422 For RS-232C/RS-422 For RS-...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/fz3series(fourcamera)_inst-5319282-8f(e).pdf

PDF視覚センサ FZ4-(H)6□□(-10) FZ4-(H)7□□(-10)

...プログラマブルコントローラやパソコンの取扱説明書を確認してください。 ピンNo. 123456789 信号名 SDB(+) SD/SDA(-) RD/RDA(-) RDB(+) NC NC NC NC GND 役割 RS-422用 RS-232C用/RS-422用 RS-232C用/RS-4...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/fz4-(h)6__(-10)_-(h)7__(-10)_-(h)11__(-10)_inst-5342160-6b.pdf

PDFE5AK Digital Controller User's Manual

...t computer E5AK (No.0) E5AK (No.30) RS-422 RS-422 RS-422 Shielded cable TerminatorX2 (240Ω1/2W) RDA RDB SDA SDB SG FG SDA 32 No. SDB 31 RDA 19 RDB 20 SG 18 SDA 32 No. SDB 31 ...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/h083-e1-03_e5ak.pdf

PDFUser's Manual Cat. No. H085-E1-03

...t computer E5EK (No.0) E5EK (No.30) RS-422 RS-422 RS-422 Shielded cable TerminatorX2 (240Ω1/2W) RDA RDB SDA SDB SG FG SDA 22 No. SDB 21 RDA 19 RDB 20 SG 18 SDA 22 No. SDB 21 ...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/h085-e1-03_e5ek.pdf

PDFUser's Manual Cat. No. H088-E1-02

...mputer E5AK-T (No.0) E5AK-T (No.30) RS-422 RS-422 RS-422 Shielded cable TerminatorX2 (240Ω1/2W) RDA RDB SDA SDB SG FG SDA 32 No. SDB 31 RDA 19 RDB 20 SG 18 SDA 32 No. SDB 31 ...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/h088-e1-02_e5ak.pdf

PDFUser's Manual Cat. No. H089-E1-02

...mputer E5EK-T (No.0) E5EK-T (No.30) RS-422 RS-422 RS-422 Shielded cable TerminatorX2 (240Ω1/2W) RDA RDB SDA SDB SG FG SDA 22 No. SDB 21 RDA 19 RDB 20 SG 18 SDA 22 No. SDB 21 ...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/h089-e1-02_e5ek-t.pdf

PDFEJ1G 倾斜温度控制用模块式温控器 操作手册 2006年10月出版

...SUB1 gッᄤA10੠B10ϡৃ⫼Ѣ᮴㶎ϱ೎ᅮッᄤⱘൟোDŽ ϡ㽕ᇍ䖭ѯッᄤ䖯㸠ӏԩⱘ䖲᥹ ᥹ষC DO NOT USE DO NOT USE B (+) A (-) RDB (+) RDA (-) SDB (+) SDA (-) COM COM + + - + + - 18 接线端子第2-2章 EDU 2-2-2接线注意事项 •...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/h143-cn5-01_ej1g_discon.pdf

PDFCat. No. H143-E1-01 User's Manual

...s. Do not connect anything to these terminals. Port C DO NOT USE DO NOT USE B (+) A (−) RDB (+) RDA (−) SDB (+) SDA (−) COM COM + + − + + − 18 Wiring Terminals Section 2-2 EDU 2-2-2 Wiring Pr...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/h143-e1-01_ej1g.pdf

Results 1021 - 1040 of 1148

Select Country in