Site Search | Product Search | IA Global Search |
... SDA Output 2 Send data + SDB Output 3 Unused NC – 4 Unused NC – 5 Unused NC – 6 Receive data – RDA Input 7 Unused NC – 8 Receive data + RDB Input 9 Unused NC – Shell Safety ground FG – Note ...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w304-e1-05_c200hw_com01_com02_v1-06_v1.pdf
... SD, RD, and SG. Link Adapter 3G2A9-AL004-E D-sub 9-pin Signal Pin No. RDB 1 – 2 SG 3 – 4 SDB 5 RDA 6 FG 7 – 8 SDA 9 SRM1 NT-AL001 Connecting Cables (Refer to page 26.) RS-422 Adapter CPM1-CI...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w318-e1-05_srm1_v2.pdf
... • Confirm polarities before connecting RS-422A/485 cables. Some devices require that SDA/B and RDA/B or signal polarities be reversed. • Double-check all wiring and switch settings before tu...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w365-e1-02_cqm1h-scb41.pdf
...8 19 HH H 20 21 22 PASS 23 L LL COM 24 25 26 Output NPN Tr. (50 mA max. at 12 to 24 VDC) LL OFF RDA RS-485 + – K31-S6: RS-422 + Transistor Terminator Outputs (50 mA max. at 12 to 24 VDC) ON S...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z082-e1-02_k3ts.pdf
...C 3A 27 26 25 24 23 22 250 VAC 3A 21 CT Communications terminal RS-232C RDB 20 29 B(+) RD 19 28 RDA 19 28 A(–) 18 27 SG 18 27 SG 18 27 SG 17 26 SD 17 26 SDA 17 26 A(–) SG 16 25 SDB 16 25 B(+)...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z103-e1-05_e5_j.pdf
... Name FG Protective frame ground For RS-232C 2 SD 3 RD 4 NC Not connected 5 RDB(+) For RS-422 6 RDA(-) 7 SDB(+) 8 SDA(-) 9 GND Signal ground The following plug and hood are recommended and ar...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z144-e1-04_f160.pdf
...tion Units RS-422 Communications Wiring The RS-422 Connector pin arrangement is as follows: RDB RDA SDB SDA SG RDB RDA SDB SDA SG • Multidrop wiring can be used. (The left and right ...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z152-e1-02_e3x-drt21_srt21_cif11.pdf
... Protective frame ground 3 2 SD RS-232C 2 3 RD RS-232C 1 4 NC Not connected 5 RDB(RD+) RS-422 6 RDA( RD- ) RS-422 7 SDB(SD+) RS-422 8 SDA( SD- ) RS-422 9 GND Connecting through the Serial Int...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z169-e1-04_v530-r160e_-r160ep.pdf
... Name FG Protective frame ground 2 SD For RS-232C 3 RD 4 NC Not connected 5 RDB(+) For RS-422 6 RDA(-) 7 SDB(+) 8 SDA(-) 9 GND Signal ground The following plug and hood are recommended and ar...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z170-e1-02e_f160-2.pdf
...1-3: OFF SW1-4: OFF SW1-5: OFF SW1-6: OFF Note Signal Signal 1 2 3 4 5 6 7 8 GRD SG SDB SDA RDB RDA CSB CSA NC 1 SD 2 RD 3 RS 4 CS 5 5V 6 DR 7 ER 8 SG 9 RS-232 RS-422 DIP SW SW1-1: ON SW1-2: ...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z194-e1-03_v600-idsc02_04.pdf
...NC NC GND Shell FG Note 1: Male connector ZFX-XPT2B/XPT5B/XPT15B Signal name FG NC NC NC RDB(+) RDA(-) SDB(+) SDA(-) GND FG FG Pin No. 1 2 3 4 5 6 7 8 9 10 Shell Pin No. 1 2 3 4 5 6 7 8 9 Sig...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z251-e1-04_zfx-c10.pdf
...me FG SD RD RS CS NC NC NC GND Shell FG 7 Note 1: Male connector Signal name FG NC NC NC RDB(+) RDA(-) SDB(+) SDA(-) GND FG FG Pin No. 1 2 3 4 5 6 7 8 9 10 Shell Pin No. 1 2 3 4 5 6 7 8 9 Sig...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z264-e1-09_zfx-c.pdf
...3 4 5 6 7* Terminal name RD (RXD) SD (TXD) SG (GND) 8 9 10 11 12 13 14 15 RDB (+) RDA () SDB (+) SDA () 9 15 Function (Not used) Enters data from the external device. Output...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z358-e1-03_mx-z2000g.pdf
...2 3 4 5 6 7 RD (RXD) SD (TXD) SG (GND) 8 9 10 11 12 13 14 15 RDB () RDA () SDB ( SDA ( (Not used) Enters data from the external device. Outputs data from the controller....
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z359-e1-03_mx-z2000g.pdf
...3 4 5 6 7* Terminal name RD (RXD) SD (TXD) SG (GND) 8 9 10 11 12 13 14 15 RDB (+) RDA () SDB (+) SDA () 9 15 Function (Not used) Enters data from the external device. Output...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z376-e1-06_mx-z2000h.pdf
...2 3 4 5 6 7 RD (RXD) SD (TXD) SG (GND) 8 9 10 11 12 13 14 15 RDB () RDA () SDB ( SDA ( (Not used) Enters data from the external device. Outputs data from the controller....
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z377-e1-06_mx-z2000h.pdf
...is used in Sensor Controller. Pin No. 9 8 7 6 1 2 3 4 5 6 7 8 9 Signal name SDB(+) SD/SDA(-) RD/RDA(-) RDB(+) NC NC NC NC GND Function For RS-422 For RS-232C/RS-422 For RS-232C/RS-422 For RS-...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z423-e1-02_fz5.pdf
...ケーブル被覆部:耐熱塩化ビニル (PVC) NC 3 3 NC 最小曲げ半径 NC 4 NC 付属品 RDB(+) 4 5 6 RDA(-) RDA(-) SDB(+) 7 7 NC SDA(-) 8 9 10 シェル 8 9 RDB(+) SG(GND) シェル FG ご使用に際...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/zfx-xpt_b_inst-1284053-0d.pdf
...fer output (E5@N-@F@) *3.Orders will not be accepted after March 31, 2018. Potentiometer *3 RDB RDA SG SDB SDA 4 to 20 mA DC (Load: 600 X max.) 4 to 20 mA DC 1 2 3 4 5 6 7 8 9 10 21 22 23 24 ...
https://www.fa.omron.com.cn/data_pdf/closed/cat/e5an-ht_e5en-ht_ds_e_1_14_csm2669.pdf
...) NT30/NT31C-KBA05 (N) USB串行转换电缆 CS1W-CIF31 USB继电器电缆 (IP65防油型) NS-USBEXT-1M NS系列 21 外形尺寸(单位:mm) RDA RDB SDA SDB RSA RSB 383.51 0 282.5 1 0 RUN 安装面板安装支架...
https://www.fa.omron.com.cn/data_pdf/closed/cat/ns_series_ca_c_11_9_discon.pdf