| IAグローバル検索 |
...• Increase the output voltage setting of the Power Supplies by the drop in the forward voltage (VF) of diodes D1 and D2. Also, the diodes will cause a power loss equivalent to the Power Suppl...
https://www.omron-ap.com.my/data_pdf/cat/s8vk-w_t219-e1_5_1_csm1066917.pdf
...• Increase the output voltage setting of the Power Supplies by the drop in the forward voltage (VF) of diodes D1 and D2. Also, the diodes will cause a power loss equivalent to the Power Suppl...
https://www.omron-ap.com.ph/data_pdf/cat/s8vk-w_t219-e1_5_1_csm1066917.pdf
...• Increase the output voltage setting of the Power Supplies by the drop in the forward voltage (VF) of diodes D1 and D2. Also, the diodes will cause a power loss equivalent to the Power Suppl...
https://www.omron-ap.com/data_pdf/cat/s8vk-w_t219-e1_5_1_csm1066917.pdf
...• Increase the output voltage setting of the Power Supplies by the drop in the forward voltage (VF) of diodes D1 and D2. Also, the diodes will cause a power loss equivalent to the Power Suppl...
https://www.omron.co.id/data_pdf/cat/s8vk-w_t219-e1_5_1_csm1066917.pdf
...• Increase the output voltage setting of the Power Supplies by the drop in the forward voltage (VF) of diodes D1 and D2. Also, the diodes will cause a power loss equivalent to the Power Suppl...
https://www.omron.com.au/data_pdf/cat/s8vk-w_t219-e1_5_1_csm1066917.pdf
... •Increase the output voltage setting of the Power Supplies by the drop in the forward voltage (VF) of diodes D1 and D2. Also, the diodes will cause a power loss equivalent to the Power Suppl...
https://www.omron.com.tw/data_pdf/cat/s8vk-w_t219-e1_5_1_csm1066917.pdf
... (max.) IOUT: Sensor control output (load current) ION:Slave ON current ION = (VCC–V R–V F)/RIN VF: Internal residual voltage of Slave RIN: Input impedance of Slave When ION is smaller than I...
https://www.omron.com.tw/data_pdf/mnu/w347-e1-06_c200hw_cqm1-drt_drt1.pdf
... T5 Synchronization Deceleration MC_SyncOut H4 DecelerationTrigger := TRUE V0=Vconveyor T T T T Vf=0 Deceleration distance: DDecel= (V0 *T5)/ 2 Maximum Deceleration rate: DecMax= 2* (V0 / T5)...
https://www.omron.com.tw/data_pdf/mnu/w539-e1-08_nj501-4500_4400_4320_4310_4300.pdf
...• Increase the output voltage setting of the Power Supplies by the drop in the forward voltage (VF) of diodes D1 and D2. Also, the diodes will cause a power loss equivalent to the Power Suppl...
https://www.omron.com.vn/data_pdf/cat/s8vk-w_t219-e1_5_1_csm1066917.pdf
...Section 2-1 E5ZD-4jjj-E/-6jjj-E Hardware Signal Input Method Internal Circuits 14 V 1 kΩ 3.9 kΩ VF = 1.2 BANK0/BANK1/BANK2 (current outflow: approx. 3 mA) VF = 0.6 ING 0V Contact Inp...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z042-e1-04_e5zd.pdf
...urrent of Unit with transistor inputs ION is obtained from the following formula. ION = (VCC–VR–VF) / RIN VF: Residual voltage of Transistor Input (Refer to page 351 for specifi- cat...
https://www.fa.omron.com.cn/data_pdf/closed/mnu/w266-e1-09_c200hw_cj1w_cqm1_srt1_srt2.pdf
... (max.) IOUT: Sensor control output (load current) ION:Slave ON current ION = (VCC–V R–V F)/RIN VF: Internal residual voltage of Slave RIN: Input impedance of Slave When ION is smaller than I...
https://www.fa.omron.com.cn/data_pdf/closed/mnu/w347-e1-06_c200hw_cqm1-drt_drt1.pdf
...M-TS カップル変換器 2D / 3D K3FM-UDS リバース変換器 2D / 3D K3FM-UDS+K3FM-REM リバース変換器, 抵抗モジュール付き 2D / 3D K3FM-VF 直流入力変換器(超高速) 2D / 3D K3FM-VF+K3FM-REM 直...
https://www.fa.omron.co.jp/products/family/1722/download/cad.html
...400 V: 3000-r/min Servomotors of 4 kW or more 1500-r/min Servomotors Flexible Cable R88A-CR1BVF The empty boxes in the model number are for the cable length. (6.0 mm dia.) Servo Drive side...
https://www.fa.omron.co.jp/data_pdf/cat/1s-51_i928-e1_3_1_csm1129313.pdf
...88A-CR1A□□□C 形R88A-CR1B□□□N 形R88A-CR1B□□□V ●屈曲ケーブル 形R88A-CR1A□□□CF 形R88A-CR1B□□□NF 形R88A-CR1B□□□VF お問い合わせ 0120-919-066 または直通電話 055-982-5015(通話料がかかります) www.f...
https://www.fa.omron.co.jp/data_pdf/cat/1s-51_sbce-177_3_1.pdf
...400 V: 3000-r/min Servomotors of 4 kW or more 1500-r/min Servomotors Flexible Cable R88A-CR1BVF The empty boxes in the model number are for the cable length. (6.0 mm dia.) Servo Drive side...
https://www.fa.omron.co.jp/data_pdf/cat/1s_series_i821-e1_10_13_csm1052864.pdf
...88A-CR1A□□□C 形R88A-CR1B□□□N 形R88A-CR1B□□□V ●屈曲ケーブル 形R88A-CR1A□□□CF 形R88A-CR1B□□□NF 形R88A-CR1B□□□VF お問い合わせ 0120-919-066 または直通電話 055-982-5015(通話料がかかります) www.f...
https://www.fa.omron.co.jp/data_pdf/cat/1s_series_sbce-082_10_15.pdf
...耐電圧 AC用抵抗負荷 DC用抵抗負荷 AC125V 6A AC250V 2A DC30V 4A AC125V 3A DC30V 2A 1a 一般負荷用 1c LED 項目順電圧VF 標準値V*(IF=10mA) LED面照光赤 黄 緑 2.0 2.1 2.1 最大値V 衝撃 耐久性 注. ...
https://www.fa.omron.co.jp/data_pdf/cat/a3a_cdmc-022_1_13.pdf
...を行った場合です。 (1) 周囲温度:20±2℃ (2) 周囲湿度:65±5%RH (3) 操作頻度:20回/min 内蔵LEDランプ項目順電圧順電流 VF IF (Ta=25℃のとき) LEDランプ色 赤 黄(白)*2 緑 標準値(V)*1 1.85 2....
https://www.fa.omron.co.jp/data_pdf/cat/a3d_cdla-033_2_10.pdf
...約1.5∼1.7g 保護構造 IEC IP00 洗浄 不可 2 最新の商品情報・便利な情報は 項目 赤 黄 緑 順電圧 VF 標準値(V) 発光色 2.0 2.0 2.1 順電流 IF 標準値(mA) 20 20 20 許容損失 P 絶対最大値(mW) 84 84 ...
https://www.fa.omron.co.jp/data_pdf/cat/b3j_cdma-023_1_10.pdf