| IAグローバル検索 |
...cator input Open collector with relay or transistor input Indicator ON: Input voltage of 0 to 2 V Indicator OFF: Open (with leakage current of 0.1 mA max.) Protection circuits Reverse-connect...
https://www.ia.omron.com/products/family/424/specification.html
...pecifications Dimensions Catalog last update: December 13, 2012 Ratings Power supply voltage 18 V (use two 9-V dry-cell batteries) Input configuration Operates when the output transi...
https://www.ia.omron.com/products/family/432/specification.html
... current: 50 mA max. OFF current: 0.5 mA max. 50 mA load current with a residual voltage of 1.0 V max. 10 mA load current with a residual voltage of 0.4 V max. Response frequency * 2...
https://www.ia.omron.com/products/family/437/specification.html
... current: 80 mA max. OFF current: 0.5 mA max. 80 mA load current with a residual voltage of 1.0 V max. 10 mA load current with a residual voltage of 0.4 V max. Response frequency *2 ...
https://www.ia.omron.com/products/family/438/specification.html
... current: 80 mA max. OFF current: 0.5 mA max. 80 mA load current with a residual voltage of 1.0 V max. 10 mA load current with a residual voltage of 0.4 V max. Response frequency *3 ...
https://www.ia.omron.com/products/family/440/specification.html
... current: 80 mA max. OFF current: 0.5 mA max. 80 mA load current with a residual voltage of 1.0 V max. 10 mA load current with a residual voltage of 0.4 V max. Response frequency *3 ...
https://www.ia.omron.com/products/family/443/specification.html
...urrent: 100 mA max. OFF current: 0.5 mA max. 100 mA load current with a residual voltage of 0.8 V max. 40 mA load current with a residual voltage of 0.4 V max. Response frequency *2 ...
https://www.ia.omron.com/products/family/444/specification.html
...tput 100 mA max. at 12 VDC (30 VDC max.) 200 mA max. at 24 VDC (30 VDC max.) Residual voltage 3 V max. (Load current: 100 mA, Cable length: 2 m) 2 V max. (Load current: 200 mA, Cable...
https://www.ia.omron.com/products/family/454/specification.html
...ntrol output Load current NPN open-collector output, 100 mA max. (at 30 VDC) Residual voltage 2 V max. (Load current: 100 mA, Cable length: 2 m) Indicators Detection indicator (red) Operation...
https://www.ia.omron.com/products/family/457/specification.html
...urrent E and F Models: 200 mA max.*2, Y Models: 10 to 200 mA Residual voltage E and F Models: 2 V max. (Load current: 200 mA, Cable length: 2 m), Y Models: Refer to Engineering Data on Data S...
https://www.ia.omron.com/products/family/471/specification.html
...DC Control output Load current NPN open collector, 100 mA max. (at 30 VDC) Residual voltage 1.5 V max. (Load current: 100 mA, Cable length: 2 m) Indicators Detection indicator (red) Number of...
https://www.ia.omron.com/products/family/472/specification.html
...pple (p-p) Current consumption 40 mA DC max. Control output 200 mA DC max. (residual voltage: 1 V max.) Indicators Operation indicator (red) Operation mode (with sensing object approaching) N...
https://www.ia.omron.com/products/family/479/specification.html
...y NPN open collector with a maximum current of 200 mA at 30 VDC 10 to 200 mA Residual voltage 3 V max. under a load current of 200 mA and a cable length of 2 m Refer to Datasheet. Indicators ...
https://www.ia.omron.com/products/family/480/specification.html
... *2 Output capacity Applied voltage: 30 VDC max. Sink current: 35 mA max. Residual voltage: 0.4 V max. (at sink current of 35 mA) Applied voltage: 30 VDC max. Source current: 35 mA max. Resid...
https://www.ia.omron.com/products/family/487/specification.html
... *2 Output capacity Applied voltage: 30 VDC max. Sink current: 35 mA max. Residual voltage: 0.4 V max. (at sink current of 35 mA) Applied voltage: 30 VDC max. Source current: 35 mA max. Resid...
https://www.ia.omron.com/products/family/488/specification.html
...r output Output capacity Output resistance: 1 kΩ Sink current: 35 mA max. Residual voltage: 0.7 V max. (at sink current of 10 mA) Applied voltage: 30 VDC max. Sink current: 35 mA max. Residua...
https://www.ia.omron.com/products/family/489/specification.html
... Complementary outputs *2 NPN open-collector output Output capacity Output voltage: VH = Vcc -3 V min. (Io = 30 mA), VL = 2 V max. (Io = -30 mA) Output current: ±30 mA Applied voltag...
https://www.ia.omron.com/products/family/490/specification.html
... *4 Output capacity Applied voltage: 35 VDC max. Sink current: 35 mA max. Residual voltage: 0.7 V max. (at sink current of 35 mA) Output resistance: 1 kΩ Sink current: 30 mA max. Residual vol...
https://www.ia.omron.com/products/family/491/specification.html
...put Output capacity Applied voltage: 28 VDC max. Sink current: 16 mA max. Residual voltage: 0.4 V max. (at sink current of 16 mA) Maximum response frequency *2 5 kHz Logic Negative logic (hig...
https://www.ia.omron.com/products/family/494/specification.html
...es A, B, and Z (phase difference signals) Phase difference 90° ±45° max. ON 6 mA max. at 0 to 2 V OFF 1.5 mA max. at 8 to 24 V Input short current 9 mA Max. applied voltage 30 ...
https://www.ia.omron.com/products/family/498/specification.html