| IAグローバル検索 |
...输出 50mA以下黑色输出褐色 100mA 以下 DC 12~24V 2.2 3.90V 负载稳定指示灯检测指示灯 (绿色)(红色) ZD ZD ZD:VZ=40V 接近传感器主回路 0V 输出 DC12~24V 100mA 以下 13 9 14...
https://www.fa.omron.com.cn/data_pdf/cat/e2c_e2c-h_ds_c_9_12.pdf
...x. 47 V 2.2Ω Proximity Sensor main circuit Blue 0 V Black Output Brown 12 to 24 VDC 100 mA max. ZD ZD 3.9Ω 2.2Ω ZD : VZ = 40 V 0 V 12 to 24 VDC Proximity Sensor main circuit...
https://www.fa.omron.com.cn/data_pdf/cat/e2c_e2c-h_ds_e_9_7_csm445.pdf
...˅ 〇ᅮ ᣛ⼎♃ ˄㓓㡆˅ PNP䕧ߎ ԧㅵ NPN䕧ߎ ԧㅵ NPN/PNP䕧ߎ ߛᤶᓔ݇ 㻤㡆咥㡆㪱㡆 ܝ⬉ Ӵᛳ఼ Џಲ䏃䋳䕑 ZD * ZD *䇋ᇚߛᤶᓔ݇䆒NPNջDŽ 䋳䕑⬉⌕ ࠊ䕧ߎ DC10̚30V 0V 入光时遮光时亮灯熄灭 ON OFF 工作复位入光指示...
...lay) 1 4 Through-beam Model Receivers: Retro-reflective Models, Reflective Models 3 1 2 4 1 4 3 ZD * ZD Photo- electric Sensor main circuit PNP output transistor NPN output transisto...
https://www.fa.omron.com.cn/data_pdf/cat/e3s-c_ds_e_9_4_csm424.pdf
...҂♃ ❘♁ ON OFF ࡼ ԡ ܹܝᣛ⼎♃ ˄㡆˅ 䕧ߎ ԧㅵ 䋳䕑 ˄㒻⬉఼ㄝ˅ δ㢨εδ㔵㢨ε 㽆㢨唇㢨㬓㢨䍕䖳 ZD ZD *䈧ሶ࠷ᦒᔰޣ䇮൘NPNחȾ 䍕䖳⭫⍷ 䗉࠰ DC10Њ30V 0V ޛݿ ⽰⚥ どᇐ ⽰⚥ ݿ⭫ Ֆ ಞѱ ഔ䐥 PNP䗉࠰ Წ։㇗ NPNȽPNP...
https://www.fa.omron.com.cn/data_pdf/cat/e3s-cl_ds_c_5_5.pdf
...istor Load (relay) PNP output transistor NPN output transistor NPN and PNP output selector Load ZD ZD *Set the NPN and PNP output selector to NPN. Load current 0 V 10 to 30 VDC Brown...
https://www.fa.omron.com.cn/data_pdf/cat/e3s-cl_ds_e_5_5_csm425.pdf
...Photo- electric Sensor main circuit 12 to 24 VDC 0 V Brown *1 Black Load Blue *1 Control output ZD Incident light No incident light ON OFF ON OFF Operate Reset Light indicator (red) (Between ...
https://www.fa.omron.com.cn/data_pdf/cat/e3s-gs3_4_ds_e_3_4_csm1302.pdf
...12̚24V 㻤㡆㪱㡆 1 3 4 3 1 DC12̚24V㻤㡆咥㡆˄ࠊ䕧ߎ˅ 㪱㡆 50mA*2 ҹϟ ࡼ ᣛ⼎♃ 〇ᅮ ᣛ⼎♃ ˄㓓㡆˅˄㡆˅ 0V ZD 䋳䕑 ˄㒻⬉఼˅ ܝ⬉ Ӵᛳ఼ Џಲ䏃 *1 *1.小型圆柱型E3T-C□□□(S)没有二极管。 *2.小型圆柱型E3T-C□□□(S...
...istor Load (e.g., relay) Operate Reset ON OFF (Between brown (1) and black (4) leads) 1 3 4 3 1 ZD 0 V Through-beam Receivers and Reflective Sensors Operation indicator (orange) Stability ind...
https://www.fa.omron.com.cn/data_pdf/cat/e3t_e407-e1_6_7_csm2648.pdf
...纤巧·睿智·简单操纤巧·睿智·简单操作数字光纤传感器 E3X-ZD系列适用于广泛应用领域的 系列的主要特点 2 简便的简便的E3X-ZD系列系列能简单操作的光纤传感器独立示教按钮: 只需2次按键,示教和感...
https://www.fa.omron.com.cn/data_pdf/cat/e3x-zd_e65z-cn5_1_7.pdf
...种反射型(E3Z-LS除外)> NPN输出型时 4 3 1 DC12~24V褐色黑色蓝色 100mA 以下动作指示灯稳定指示灯 (绿色)(橙色) 0V ZD 负载 (继电器) 光电传感器主回路 eco Pb 有关标准认证对象机型的最新信息,...
...4 VDC Brown Black Blue 100 mA max. Operation indicator (orange) Stability indicator (green) 0 V ZD Load (relay) Photo- electric Sensor main circuit eco Pb 2 E3Z Ordering Information Sensors [...
...4 VDC Brown Black Blue 100 mA max. Operation indicator (orange) Stability indicator (green) 0 V ZD Load (relay) Photo- electric Sensor main circuit eco Pb E3Z 2 Ordering Information Sensors [...
https://www.fa.omron.com.cn/data_pdf/cat/e3z_ds_e_18_9_csm438.pdf
...ᖈਃሺශɄɃᢟᮙਃሺශɄ 4 3 1 DC 10Њ30V㽆㢨唇㢨δ䗉࠰ε 㬓㢨 100mA ԛс ࣞ֒ ⽰⚥ どᇐ ⽰⚥ δ㔵㢨εδ哺㢨ε 0V ZD 䍕䖳 δ㔝⭫ಞε ݿ⭫ Ֆಞ ѱഔ䐥 ࣞ֒⽰⚥ δ哺㢨ε ɏ㽆㢨δŚει唇㢨δŝεҁ䰪ɐ 䗉࠰ Წ։㇗ 䍕䖳 δ㔝⭫ಞㅿε ޛݿᰬ 䚤ݿᰬ Ӥ⚥ ➺⚣ ...
...tor (yellow) (Between brown and black leads) Output transistor Load (e.g., relay) 1 4 4 3 1 0 V ZD Through-beam Receivers, Retro-reflective Models, Diffuse-reflective Models 10 to 30 VDC Brow...
https://www.fa.omron.com.cn/data_pdf/cat/e3zm_ds_e_6_1_csm2159.pdf
...的受光器><回归反射型><扩散反射型> 4 3 1 DC12~24V褐黑(控制输出) 蓝 100mA 以下动作指示灯稳定指示灯 (绿) (橙) 0V ZD 负载 (继电器) 光电传感器主电路动作指示灯 (橙色) 〔褐(①)-黑(④)之间〕 输出晶体...
https://www.fa.omron.com.cn/data_pdf/cat/e3zr-c_r001-cn5-001_1_3.pdf
...㑶㡆˅ Ẕ⌟⠽ԧ 䕧ߎԧㅵ 䋳䕑 ˄㒻⬉఼ㄝ˅ 㻤㡆 ⱑ㡆㪱㡆咥㡆 DC 12~24V Џಲ䏃 䋳䕑 㒻⬉఼ ˄ǂǂ˅ࠊ 䕧ߎ ZD ZD ᳔50mA ˄ᡩܝذℶ䕧ܹ˅ ᣛ⼎♃ ˄㑶㡆˅ ᳝᮴ ҂♃ ❘♁ ON OFF ࡼ ᔦԡ ᣛ⼎♃ ˄㑶㡆˅ Ẕ⌟⠽ԧ 䕧ߎԧㅵ 䋳䕑 ˄㒻⬉఼ㄝ˅ ...
https://www.fa.omron.com.cn/data_pdf/cat/ee-sa701_801_ds_c_4_2.pdf
...e.g., relay) Brown White Blue Black 12 to 24 VDC Push indicator (red) Main circuit Load (relay) ZD ZD 50 mA max. (External diagnosis input) (Control output) Present Absent ON OFF ON ...
https://www.fa.omron.com.cn/data_pdf/cat/ee-sa701_801_ds_e_4_3_csm662.pdf
...ts caused by power supply problems or ESD transients. Resets include watchdog reset, ,
https://www.fa.omron.com.cn/data_pdf/mnu/84-000830-f_qx-830.pdf
...ts caused by power supply problems or ESD transients. Resets include watchdog reset, ,
https://www.fa.omron.com.cn/data_pdf/mnu/84-000870-g_qx-870.pdf