Primary Contents

IAグローバル検索結果

国/地域選択

IAグローバル検索
結果 2821 - 284055512
EE-SX673A | OMRON Industrial Automation

...supply voltage 5 to 24 VDC Load curren 100 mA max. Residual voltage at 100 mA load current: 0.8 V max. at 40 mA load current: 0.4 V max. Protection circuits Output short-cut protecti...

https://www.ia.omron.com/product/item/2231/

EE-SX673P | OMRON Industrial Automation

...r supply voltage 5 to 24 VDC Load curren 50 mA max. Residual voltage at 50 mA load current: 1.3 V max. Protection circuits Output short-cut protection Response frequency elements 1 kHz min. A...

https://www.ia.omron.com/product/item/2232/

EE-SX673R | OMRON Industrial Automation

...r supply voltage 5 to 24 VDC Load curren 50 mA max. Residual voltage at 50 mA load current: 1.3 V max. Protection circuits Output short-cut protection Response frequency elements 1 kHz min. A...

https://www.ia.omron.com/product/item/2234/

EE-SX674 | OMRON Industrial Automation

...supply voltage 5 to 24 VDC Load curren 100 mA max. Residual voltage at 100 mA load current: 0.8 V max. at 40 mA load current: 0.4 V max. Protection circuits Output short-cut protecti...

https://www.ia.omron.com/product/item/2236/

EE-SX674A | OMRON Industrial Automation

...supply voltage 5 to 24 VDC Load curren 100 mA max. Residual voltage at 100 mA load current: 0.8 V max. at 40 mA load current: 0.4 V max. Protection circuits Output short-cut protecti...

https://www.ia.omron.com/product/item/2237/

EE-SX674P | OMRON Industrial Automation

...r supply voltage 5 to 24 VDC Load curren 50 mA max. Residual voltage at 50 mA load current: 1.3 V max. Protection circuits Output short-cut protection Response frequency elements 1 kHz min. A...

https://www.ia.omron.com/product/item/2238/

EE-SX674R | OMRON Industrial Automation

...r supply voltage 5 to 24 VDC Load curren 50 mA max. Residual voltage at 50 mA load current: 1.3 V max. Protection circuits Output short-cut protection Response frequency elements 1 kHz min. A...

https://www.ia.omron.com/product/item/2240/

EE-SX675 | OMRON Industrial Automation

...supply voltage 5 to 24 VDC Load curren 100 mA max. Residual voltage at 100 mA load current: 0.8 V max. at 40 mA load current: 0.4 V max. Protection circuits Output short-cut protecti...

https://www.ia.omron.com/product/item/2242/

EE-SX675P | OMRON Industrial Automation

...r supply voltage 5 to 24 VDC Load curren 50 mA max. Residual voltage at 50 mA load current: 1.3 V max. Protection circuits Output short-cut protection Response frequency elements 1 kHz min. A...

https://www.ia.omron.com/product/item/2243/

EE-SX676 | OMRON Industrial Automation

...supply voltage 5 to 24 VDC Load curren 100 mA max. Residual voltage at 100 mA load current: 0.8 V max. at 40 mA load current: 0.4 V max. Protection circuits Output short-cut protecti...

https://www.ia.omron.com/product/item/2246/

EE-SX676P | OMRON Industrial Automation

...r supply voltage 5 to 24 VDC Load curren 50 mA max. Residual voltage at 50 mA load current: 1.3 V max. Protection circuits Output short-cut protection Response frequency elements 1 kHz min. A...

https://www.ia.omron.com/product/item/2247/

EE-SX677 | OMRON Industrial Automation

...supply voltage 5 to 24 VDC Load curren 100 mA max. Residual voltage at 100 mA load current: 0.8 V max. at 40 mA load current: 0.4 V max. Protection circuits Output short-cut protecti...

https://www.ia.omron.com/product/item/2250/

EE-SX677P | OMRON Industrial Automation

...r supply voltage 5 to 24 VDC Load curren 50 mA max. Residual voltage at 50 mA load current: 1.3 V max. Protection circuits Output short-cut protection Response frequency elements 1 kHz min. A...

https://www.ia.omron.com/product/item/2251/

E3T-FT11F 2M | OMRON Industrial Automation

...iver: 20 mA max. Control output NPN open collector 26.4 VDC max. 50 mA max. Residual voltage: 1 V max. (Load current Less than 10 mA) Residual voltage: 2 V max. (Load current 10 to 5...

https://www.ia.omron.com/product/item/234/

E3T-FT12F 2M | OMRON Industrial Automation

...iver: 20 mA max. Control output NPN open collector 26.4 VDC max. 50 mA max. Residual voltage: 1 V max. (Load current Less than 10 mA) Residual voltage: 2 V max. (Load current 10 to 5...

https://www.ia.omron.com/product/item/241/

E6B2-CWZ5B 600P/R 2M | OMRON Industrial Automation

...ut phases A, B and Z Control output Output type PNP open collector Load power supply voltage 30 V max.DC Source current 35 mA max. Residual voltage 0.4 V max. (at source current 35 m...

https://www.ia.omron.com/product/item/2448/

E3T-FT13F 2M | OMRON Industrial Automation

...iver: 20 mA max. Control output PNP open collector 26.4 VDC max. 50 mA max. Residual voltage: 1 V max. (Load current Less than 10 mA) Residual voltage: 2 V max. (Load current 10 to 5...

https://www.ia.omron.com/product/item/247/

E6C2-CWZ1X 720P/R 2M | OMRON Industrial Automation

...ses A, -A, B, -B, Z and -Z Control output Output type Line driver output Output voltage Vo: 2.5 V min. Vs: 0.5 V max. Load current High level (Io): -20 mA Low level (Is): 20 mA Start...

https://www.ia.omron.com/product/item/2507/

E6C2-CWZ1X 800P/R 2M | OMRON Industrial Automation

...ses A, -A, B, -B, Z and -Z Control output Output type Line driver output Output voltage Vo: 2.5 V min. Vs: 0.5 V max. Load current High level (Io): -20 mA Low level (Is): 20 mA Start...

https://www.ia.omron.com/product/item/2508/

E6C2-CWZ3E 1024P/R 2M | OMRON Industrial Automatio...

...put type NPN voltage output Output resistance 2 kΩ Load current 20 mA max. Residual voltage 0.4 V max. (at sink current 20 mA) Starting positional point Equipped Max. response frequency 100 k...

https://www.ia.omron.com/product/item/2511/