Primary Contents

IAグローバル検索結果

国/地域選択

IAグローバル検索
結果 2801 - 282053890
E3T-SL23M 5M | OMRON Industrial Automation

...ption 20 mA max. Control output PNP open collector 26.4 VDC max. 50 mA max. Residual voltage: 1 V max. (Load current Less than 10 mA) Residual voltage: 2 V max. (Load current 10 to 5...

https://www.ia.omron.com/product/item/68266/

E3T-ST12M 5M | OMRON Industrial Automation

...iver: 20 mA max. Control output NPN open collector 26.4 VDC max. 50 mA max. Residual voltage: 1 V max. (Load current Less than 10 mA) Residual voltage: 2 V max. (Load current 10 to 5...

https://www.ia.omron.com/product/item/68267/

E3T-ST13M 5M | OMRON Industrial Automation

...iver: 20 mA max. Control output PNP open collector 26.4 VDC max. 50 mA max. Residual voltage: 1 V max. (Load current Less than 10 mA) Residual voltage: 2 V max. (Load current 10 to 5...

https://www.ia.omron.com/product/item/68268/

E3T-ST14M 5M | OMRON Industrial Automation

...iver: 20 mA max. Control output PNP open collector 26.4 VDC max. 50 mA max. Residual voltage: 1 V max. (Load current Less than 10 mA) Residual voltage: 2 V max. (Load current 10 to 5...

https://www.ia.omron.com/product/item/68269/

E3T-ST22M 5M | OMRON Industrial Automation

...iver: 20 mA max. Control output NPN open collector 26.4 VDC max. 50 mA max. Residual voltage: 1 V max. (Load current Less than 10 mA) Residual voltage: 2 V max. (Load current 10 to 5...

https://www.ia.omron.com/product/item/68270/

G3NA-205B-UTU AC100-240 | OMRON Industrial Automat...

...0 to 240 VAC Operating voltage range 75 to 264 VAC Input impedance 72 kΩ±20% Operate voltage 75 V max.AC Release voltage 20 V min.AC Output Rated load voltage 24 to 240 VAC Load volt...

https://www.ia.omron.com/product/item/72433/

G3NA-210B-UTU AC100-240 | OMRON Industrial Automat...

...0 to 240 VAC Operating voltage range 75 to 264 VAC Input impedance 72 kΩ±20% Operate voltage 75 V max.AC Release voltage 20 V min.AC Output Rated load voltage 24 to 240 VAC Load volt...

https://www.ia.omron.com/product/item/72434/

G3NA-220B-UTU AC100-240 | OMRON Industrial Automat...

...0 to 240 VAC Operating voltage range 75 to 264 VAC Input impedance 72 kΩ±20% Operate voltage 75 V max.AC Release voltage 20 V min.AC Output Rated load voltage 24 to 240 VAC Load volt...

https://www.ia.omron.com/product/item/72435/

G3NA-240B-UTU AC100-240 | OMRON Industrial Automat...

...0 to 240 VAC Operating voltage range 75 to 264 VAC Input impedance 72 kΩ±20% Operate voltage 75 V max.AC Release voltage 20 V min.AC Output Rated load voltage 24 to 240 VAC Load volt...

https://www.ia.omron.com/product/item/72436/

G3NA-410B-UTU AC100-240 | OMRON Industrial Automat...

...0 to 240 VAC Operating voltage range 75 to 264 VAC Input impedance 72 kΩ±20% Operate voltage 75 V max.AC Release voltage 20 V min.AC Output Rated load voltage 200 to 480 VAC Load vol...

https://www.ia.omron.com/product/item/72437/

G3NA-420B-UTU AC100-240 | OMRON Industrial Automat...

...0 to 240 VAC Operating voltage range 75 to 264 VAC Input impedance 72 kΩ±20% Operate voltage 75 V max.AC Release voltage 20 V min.AC Output Rated load voltage 200 to 480 VAC Load vol...

https://www.ia.omron.com/product/item/72438/

G3NA-420B-UTU DC5-24 | OMRON Industrial Automation

...ing Input Rated voltage 5 to 24 VDC Operating voltage range 4 to 32 VDC Input current 5 mA max.{V} (Constant current input circuit system) Operate voltage 4 V max.DC Release voltage ...

https://www.ia.omron.com/product/item/72439/

G3NA-440B-UTU-2 AC100-240 | OMRON Industrial Autom...

...0 to 240 VAC Operating voltage range 75 to 264 VAC Input impedance 72 kΩ±20% Operate voltage 75 V max.AC Release voltage 20 V min.AC Output Rated load voltage 200 to 480 VAC Load vol...

https://www.ia.omron.com/product/item/72440/

G3NA-440B-UTU-2 DC5-24 | OMRON Industrial Automati...

...ing Input Rated voltage 5 to 24 VDC Operating voltage range 4 to 32 VDC Input current 5 mA max.{V} (Constant current input circuit system) Operate voltage 4 V max.DC Release voltage ...

https://www.ia.omron.com/product/item/72441/

G3NA-205B-UTU DC5-24 | OMRON Industrial Automation

...ing Input Rated voltage 5 to 24 VDC Operating voltage range 4 to 32 VDC Input current 7 mA max.{V} (Constant current input circuit system) Operate voltage 4 V max.DC Release voltage ...

https://www.ia.omron.com/product/item/7686/

G3NA-210B-UTU DC5-24 | OMRON Industrial Automation

...ing Input Rated voltage 5 to 24 VDC Operating voltage range 4 to 32 VDC Input current 7 mA max.{V} (Constant current input circuit system) Operate voltage 4 V max.DC Release voltage ...

https://www.ia.omron.com/product/item/7692/

G3NA-220B-UTU DC5-24 | OMRON Industrial Automation

...ing Input Rated voltage 5 to 24 VDC Operating voltage range 4 to 32 VDC Input current 7 mA max.{V} (Constant current input circuit system) Operate voltage 4 V max.DC Release voltage ...

https://www.ia.omron.com/product/item/7698/

G3NA-240B-UTU DC5-24 | OMRON Industrial Automation

...ing Input Rated voltage 5 to 24 VDC Operating voltage range 4 to 32 VDC Input current 7 mA max.{V} (Constant current input circuit system) Operate voltage 4 V max.DC Release voltage ...

https://www.ia.omron.com/product/item/7704/

G3NA-275B-UTU-2 DC5-24 | OMRON Industrial Automati...

...ing Input Rated voltage 5 to 24 VDC Operating voltage range 4 to 32 VDC Input current 7 mA max.{V} (Constant current input circuit system) Operate voltage 4 V max.DC Release voltage ...

https://www.ia.omron.com/product/item/7705/

G3NA-290B-UTU-2 DC5-24 | OMRON Industrial Automati...

...ing Input Rated voltage 5 to 24 VDC Operating voltage range 4 to 32 VDC Input current 7 mA max.{V} (Constant current input circuit system) Operate voltage 4 V max.DC Release voltage ...

https://www.ia.omron.com/product/item/7706/