IAグローバル検索 |
...20.2 Normal load *1 2.2 22.0 Light load 3.0 24.0 Model 3G3AX-DL2002 Heat Inductance generation [mH] [W] Operating ambient temperature/ humidity Location 21.4 8 3G3AX-DL2004 10.7 3G3AX-DL2007 ...
https://www.omron-ap.co.th/data_pdf/cat/mx2-v2_ds_e_3_1_csm1126864.pdf
...ions Reactor type Single-phase Reactors Three-phase Reactor Model Rated current (A) Inductance (mH) Weight (kg) 3G3AX-DL2002 1.6 A 21.4 mH 0.8 kg 3G3AX-DL2004 3.2 A 10.7 mH ...
https://www.omron-ap.co.th/data_pdf/cat/r88m-g_r7d-bp_i813-e1_9_15_csm2685.pdf
...3RX2-A2450 3G3RX2-A2550 DC reactor specifications Operating Heat Inductance ambient generation [mH] temperature [W] /humidity 10.7 8 3G3AX-DL2007 6.75 15 3G3AX-DL2015 3.51 25 10.8 12 13.9 3G3...
https://www.omron-ap.co.th/data_pdf/cat/rx2_i921-e1_2_7_csm1070916.pdf
...RIVATE LIMITED THE QUBE 5th Floor, Unit No. 501 - 504, M V Road, Marol, Andheri (EAST), Mumbai -MH-400059, India Tel: (91) 22-7128-8400/Fax: (91) 22-7128-8401 OMRON TAIWAN ELECTRONICS INC. 6F...
https://www.omron-ap.co.th/data_pdf/cat/tm_s_i892-e_2_1_csm1126729.pdf
...=a(Ibrnユ11f)ssll皿illj5tTadoS) 12∼14Nm ・(㎞te幽asT㎞ Itmraarnbimtedefumbiamiento'])4NS-SK30-10℃a55℃丘mh泌 il・lasadeD4NS-SK3028㎏ap輌{iamente Giakv〔∬in白麹A9)messungen醐dt:〕㎜■Dhmensi(nsd...
https://www.omron-ap.co.th/data_pdf/mnu/d4ns-sk30_inst-0686729-9b.pdf
... Specifications 3 Specifications Reactor type Three-phase Reactor Rated current (A) Inductance (mH) Weight (kg) 3G3AX-DL2002 1.6 A 21.4 mH 0.8 kg 3G3AX-DL2004 3.2 A 10.7 mH ...
https://www.omron-ap.co.th/data_pdf/mnu/i561-e1-08_r88m-g_r7d-bp.pdf
...odel Number of power phases R88D-KTA5L Reactor Model Rated current Inductance Weight 1.6 A 21.4 mH Approx. 0.8 kg 3G3AX-DL2004 3.2 A 10.7 mH Approx. 1.0 kg R88D-KT02L 3G3AX-DL2007 6....
https://www.omron-ap.co.th/data_pdf/mnu/i571-e1-08_r88m-k_r88d-kt.pdf
... 3 Reactor Number of power phases Model Rated current Inductance Weight 3G3AX-DL2002 1.6 A 21.4 mH Approx. 0.8 kg 3G3AX-DL2004 3.2 A 10.7 mH Approx. 1.0 kg 3G3AX-DL2007 6.1 A 6....
https://www.omron-ap.co.th/data_pdf/mnu/i572-e1-04_r88m-k__r88d-kn_-ml2.pdf
...rent Inductance Weight Reactor type R88D-KP01H (For single-phase input) 3G3AX-DL2002 1.6 A 21.4 mH Approx. 0.8 kg DC reactor R88D-KP02H (For single-phase input) 3G3AX-DL2004 3.2 A 10.7 ...
...28 µsec typical (hardware only) Output voltage at inductive load turnoff (Iout = 0.5A, Load = 1 mH) (+V - 65) ≤ Vdemag≤ (+V - 45) DC short circuit current limit 0.7A ≤ ILIM ≤ 2.5 A Peak short...
https://www.omron-ap.co.th/data_pdf/mnu/i593-e-05_ecobra__00.pdf
...ion Parameter Value ware only) Output voltage at inductive load turnoff (Iout = 0.5 A, Load = 1 mH) (+V - 65) ≤ Vdemag ≤ (+V - 45) DC short circuit current limit 0.7 A ≤ ILIM ≤ 2.5 A Peak sho...
https://www.omron-ap.co.th/data_pdf/mnu/i596-e-08_hornet565.pdf
...8 µsec typical (hardware only) Output voltage at inductive load turnoff (Iout = 0.5 A, Load = 1 mH) (+V - 65) ≤ Vdemag ≤ (+V - 45) DC short circuit current limit 0.7 A ≤ ILIM ≤ 2.5 A Peak sho...
https://www.omron-ap.co.th/data_pdf/mnu/i597-e-05_quattro_650h(s)_800h(s).pdf
...8 µsec typical (hardware only) Output voltage at inductive load turnoff (Iout = 0.5 A, Load = 1 mH) (+V - 65) ≤ Vdemag ≤ (+V - 45) DC short circuit current limit 0.7 A ≤ ILIM Peak short circu...
https://www.omron-ap.co.th/data_pdf/mnu/i599-e-05_viper___0_emb-60r.pdf
...l lights, LCD or touch screen). 3. Plug the joystick into the robot’s JOYSTICK connection port (MH-LD shown below): Figure 3-11: Connecting the joystick to the robot CAUTION: Driving the robo...
https://www.omron-ap.co.th/data_pdf/mnu/i614-e-01_mobile_robot_software_suite.pdf
...x.), 28 μsec typical (typical) Output voltage at inductive load turnoff (Iout = 0.5 A, Load = 1 mH) (+V - 65) ≤ Vdemag ≤ (+V 45) DC short circuit current limit 0.7A ≤ ILIM ≤ 2.5 A Peak short ...
https://www.omron-ap.co.th/data_pdf/mnu/i653-e-03_ecobra__00.pdf
... Output voltage at inductive (+V - 65) ≤ Vdemag ≤ (+V - 45) load turnoff (Iout = 0.5A, Load = 1 mH) DC short circuit current limit 0.7A ≤ ILIM ≤ 2.5 A Peak short circuit current Iovpk ≤ 4 A N...
https://www.omron-ap.co.th/data_pdf/mnu/i654-e-02_viper_650_850.pdf
... Output voltage at inductive (+V - 65) ≤ Vdemag ≤ (+V - 45) load turnoff (Iout = 0.5A, Load = 1 mH) DC short circuit current limit 0.7A ≤ ILIM ≤ 2.5 A Peak short circuit current Iovpk ≤ 4 A N...
... Output voltage at inductive (+V - 65) ≤ Vdemag ≤ (+V - 45) load turnoff (Iout = 0.5A, Load = 1 mH) DC short circuit current limit 0.7A ≤ ILIM ≤ 2.5 A Peak short circuit current Iovpk ≤ 4 A N...
...age at inductive load (turn OFF) (+V - 52) ≤ Vdemag ≤ (+V - 41) where Iout = 0.5 A and load ≥ 1 mH Belt Encoder Specifications Specifications for the XBELTIO connections are provided below. I...
https://www.omron-ap.co.th/data_pdf/mnu/i658-e-08_i4-350l_450l_550l.pdf
...age at inductive load (turn OFF) (+V - 52) ≤ Vdemag ≤ (+V - 41) where Iout = 0.5 A and load ≥ 1 mH Belt Encoder Specifications Specifications for the XBELTIO connections are provided below. I...
https://www.omron-ap.co.th/data_pdf/mnu/i659-e-01_i4-350l_450l_550l.pdf