Primary Contents

IAグローバル検索結果

国/地域選択

IAグローバル検索
結果 321 - 340687
PDFCat. No. I572-E1-04 USER’S MANUAL

... 3 Reactor Number of power phases Model Rated current Inductance Weight 3G3AX-DL2002 1.6 A 21.4 mH Approx. 0.8 kg 3G3AX-DL2004 3.2 A 10.7 mH Approx. 1.0 kg 3G3AX-DL2007 6.1 A 6....

https://www.omron-ap.co.nz/data_pdf/mnu/i572-e1-04_r88m-k__r88d-kn_-ml2.pdf

PDFAC SERVOMOTORS/SERVO DRIVES G5-series

...rent Inductance Weight Reactor type R88D-KP01H (For single-phase input) 3G3AX-DL2002 1.6 A 21.4 mH Approx. 0.8 kg DC reactor R88D-KP02H (For single-phase input) 3G3AX-DL2004 3.2 A 10.7 ...

https://www.omron-ap.co.nz/data_pdf/mnu/i584-e1-02.pdf

PDFeCobra 600, 800 and 800 Inverted Robots

...28 µsec typical (hardware only) Output voltage at inductive load turnoff (Iout = 0.5A, Load = 1 mH) (+V - 65) ≤ Vdemag≤ (+V - 45) DC short circuit current limit 0.7A ≤ ILIM ≤ 2.5 A Peak short...

https://www.omron-ap.co.nz/data_pdf/mnu/i593-e-05_ecobra__00.pdf

PDFHornet 565 Robot User’s Guide I596-E-08

...ion Parameter Value ware only) Output voltage at inductive load turnoff (Iout = 0.5 A, Load = 1 mH) (+V - 65) ≤ Vdemag ≤ (+V - 45) DC short circuit current limit 0.7 A ≤ ILIM ≤ 2.5 A Peak sho...

https://www.omron-ap.co.nz/data_pdf/mnu/i596-e-08_hornet565.pdf

PDFQuattro 650H/650HS/800H/800HS User’s Guide

...8 µsec typical (hardware only) Output voltage at inductive load turnoff (Iout = 0.5 A, Load = 1 mH) (+V - 65) ≤ Vdemag ≤ (+V - 45) DC short circuit current limit 0.7 A ≤ ILIM ≤ 2.5 A Peak sho...

https://www.omron-ap.co.nz/data_pdf/mnu/i597-e-05_quattro_650h(s)_800h(s).pdf

PDFViper 650/850 Robot with eMB-60R

...8 µsec typical (hardware only) Output voltage at inductive load turnoff (Iout = 0.5 A, Load = 1 mH) (+V - 65) ≤ Vdemag ≤ (+V - 45) DC short circuit current limit 0.7 A ≤ ILIM Peak short circu...

https://www.omron-ap.co.nz/data_pdf/mnu/i599-e-05_viper___0_emb-60r.pdf

PDFMobile Robot Software Suite User’s Guide

...l lights, LCD or touch screen). 3. Plug the joystick into the robot’s JOYSTICK connection port (MH-LD shown below): Figure 3-11: Connecting the joystick to the robot CAUTION: Driving the robo...

https://www.omron-ap.co.nz/data_pdf/mnu/i614-e-01_mobile_robot_software_suite.pdf

PDFeCobra 600 and 800 Robot with EtherCAT

...x.), 28 μsec typical (typical) Output voltage at inductive load turnoff (Iout = 0.5 A, Load = 1 mH) (+V - 65) ≤ Vdemag ≤ (+V 45) DC short circuit current limit 0.7A ≤ ILIM ≤ 2.5 A Peak short ...

https://www.omron-ap.co.nz/data_pdf/mnu/i653-e-03_ecobra__00.pdf

PDFViper 650/850 Robot with EtherCAT

... Output voltage at inductive (+V - 65) ≤ Vdemag ≤ (+V - 45) load turnoff (Iout = 0.5A, Load = 1 mH) DC short circuit current limit 0.7A ≤ ILIM ≤ 2.5 A Peak short circuit current Iovpk ≤ 4 A N...

https://www.omron-ap.co.nz/data_pdf/mnu/i654-e-02_viper_650_850.pdf

PDFiX3 Robot with EtherCAT User's Manual

... Output voltage at inductive (+V - 65) ≤ Vdemag ≤ (+V - 45) load turnoff (Iout = 0.5A, Load = 1 mH) DC short circuit current limit 0.7A ≤ ILIM ≤ 2.5 A Peak short circuit current Iovpk ≤ 4 A N...

https://www.omron-ap.co.nz/data_pdf/mnu/i655-e-01_ix3.pdf

PDFiX4 650 H/HS and 800 H/HS Robot

... Output voltage at inductive (+V - 65) ≤ Vdemag ≤ (+V - 45) load turnoff (Iout = 0.5A, Load = 1 mH) DC short circuit current limit 0.7A ≤ ILIM ≤ 2.5 A Peak short circuit current Iovpk ≤ 4 A N...

https://www.omron-ap.co.nz/data_pdf/mnu/i656-e-02_ix4.pdf

PDFi4L Robots User's Manual i4-350L

...age at inductive load (turn OFF) (+V - 52) ≤ Vdemag ≤ (+V - 41) where Iout = 0.5 A and load ≥ 1 mH Belt Encoder Specifications Specifications for the XBELTIO connections are provided below. I...

https://www.omron-ap.co.nz/data_pdf/mnu/i658-e-08_i4-350l_450l_550l.pdf

PDFi4L Robots with EtherCAT User's Manual

...age at inductive load (turn OFF) (+V - 52) ≤ Vdemag ≤ (+V - 41) where Iout = 0.5 A and load ≥ 1 mH Belt Encoder Specifications Specifications for the XBELTIO connections are provided below. I...

https://www.omron-ap.co.nz/data_pdf/mnu/i659-e-01_i4-350l_450l_550l.pdf

PDFi4H Robots User's Manual i4-650H

...age at inductive load (turn OFF) (+V - 52) ≤ Vdemag ≤ (+V - 41) where Iout = 0.5 A and load ≥ 1 mH TIO Specifications Specifications for the TIO circuits are provided below. Type Input circui...

https://www.omron-ap.co.nz/data_pdf/mnu/i660-e-04_i4-650h_750h_850h.pdf

PDFi4H Robots with EtherCAT User's Manual

...e at inductive load (turn OFF) (+V - 52) ≤ Vdemag ≤ (+V - 41) where Iout = 2 0.5 A and load ≥ 1 mH TIO Specifications Specifications for the TIO circuits are provided below. Type Input circui...

https://www.omron-ap.co.nz/data_pdf/mnu/i661-e-06_i4h.pdf

PDFInverter RX2 Series EtherCAT® Communication Unit

...Not possible 403B 81 3B0A Async. Motor constant L, 1st-motor Hb114 RW 1 to 1000000000 0.000001 (mH) Not possible 403B 83 3B0C Async. Motor constant Io, 1st-motor Hb116 RW 1 to 1000000 0.01 (A...

https://www.omron-ap.co.nz/data_pdf/mnu/i663-e1-02_3g3ax-rx2-ect.pdf

PDFCat. No. W418-E1-08 SYSMAC CXONE-AL@@D-V4

... type LL (Low/low alarm) L (Low alarm) H (High alarm) HH (High/high alarm) DV (Deviation alarm) MH (High MV limit) ML (Low MV limit) Tag ITEM LL (ITEM 016) L (ITEM 015) H (ITEM 014) HH (ITEM ...

https://www.omron-ap.co.nz/data_pdf/mnu/w418-e1-08_cxone-al___-v4.pdf

PDFCat. No. W428-E1-03 SYSMAC WS02-LCMC1-EV2

...ed AUTO or remote (CAS) Manual Manual Pointer No Manual Pointer Output limit (ML) Output limit (MH) Make Manual Pointer and MV open direction settings when registering the Control Screen. Ref...

https://www.omron-ap.co.nz/data_pdf/mnu/w428-e1-03_ws02-lcmc1-ev2.pdf

PDFEQUO Series Portable Power Monitor

...teries (when using battery power supply) 2 Alkaline dry cells or nickel-metal hydride cells (Ni-MH) Important Manganese battery cells cannot be used. Use two batteries of the same type. Do no...

https://www.omron-ap.co.nz/data_pdf/mnu/z410-e1-04_zn-ctx21_kmx21.pdf

PDFAutonomous Mobile Robot OMRON MD-650 AMR

...PRIVATE LIMITED THE QUBE 5th Floor, Unit No. 501 - 504, M V Road, Marol Andheri (EAST), Mumbai -MH-400059, India Tel: (91) 22-7128-8400/Fax: (91) 22-7128-8401 OMRON (CHINA) CO., LTD. Room 221...

https://www.omron-ap.co.th/data_pdf/cat/md-650_i890-e_1_1_csm1126873.pdf