...ated current (Nominal value) 50 Hz: 0.090 A 60 Hz: 0.080 A Rated input (Nominal value) 50 Hz: 7 W 60 Hz: 6 W Rated rotational speed (Nominal value) 50 Hz: 2200 r/min 60 Hz: 2500 r/mi...
...ted current (Nominal value) 50 Hz: 0.150 A 60 Hz: 0.130 A Rated input (Nominal value) 50 Hz: 13 W 60 Hz: 11 W Rated rotational speed (Nominal value) 50 Hz: 2550 r/min 60 Hz: 3050 r/m...
...ated current (Nominal value) 50 Hz: 0.100 A 60 Hz: 0.085 A Rated input (Nominal value) 50 Hz: 7 W 60 Hz: 6 W Rated rotational speed (Nominal value) 50 Hz: 1900 r/min 60 Hz: 2200 r/mi...
...ted current (Nominal value) 50 Hz: 0.160 A 60 Hz: 0.130 A Rated input (Nominal value) 50 Hz: 14 W 60 Hz: 12 W Rated rotational speed (Nominal value) 50 Hz: 2400 r/min 60 Hz: 2800 r/m...
...ted current (Nominal value) 50 Hz: 0.130 A 60 Hz: 0.110 A Rated input (Nominal value) 50 Hz: 12 W 60 Hz: 10 W Rated rotational speed (Nominal value) 50 Hz: 1700 r/min 60 Hz: 2000 r/m...
...ted current (Nominal value) 50 Hz: 0.190 A 60 Hz: 0.170 A Rated input (Nominal value) 50 Hz: 15 W 60 Hz: 14 W Rated rotational speed (Nominal value) 50 Hz: 2750 r/min 60 Hz: 3200 r/m...
...ted current (Nominal value) 50 Hz: 0.140 A 60 Hz: 0.120 A Rated input (Nominal value) 50 Hz: 11 W 60 Hz: 10 W Rated rotational speed (Nominal value) 50 Hz: 2100 r/min 60 Hz: 2250 r/m...
...ated current (Nominal value) 50 Hz: 0.085 A 60 Hz: 0.070 A Rated input (Nominal value) 50 Hz: 7 W 60 Hz: 6 W Rated rotational speed (Nominal value) 50 Hz: 2600 r/min 60 Hz: 3000 r/mi...
...ated current (Nominal value) 50 Hz: 0.055 A 60 Hz: 0.048 A Rated input (Nominal value) 50 Hz: 5 W 60 Hz: 4 W Rated rotational speed (Nominal value) 50 Hz: 1900 r/min 60 Hz: 2100 r/mi...
...ted current (Nominal value) 50 Hz: 0.120 A 60 Hz: 0.100 A Rated input (Nominal value) 50 Hz: 10 W 60 Hz: 9 W Rated rotational speed (Nominal value) 50 Hz: 2700 r/min 60 Hz: 3200 r/mi...
...ated current (Nominal value) 50 Hz: 0.080 A 60 Hz: 0.070 A Rated input (Nominal value) 50 Hz: 7 W 60 Hz: 6 W Rated rotational speed (Nominal value) 50 Hz: 2200 r/min 60 Hz: 2500 r/mi...
...ted current (Nominal value) 50 Hz: 0.125 A 60 Hz: 0.100 A Rated input (Nominal value) 50 Hz: 13 W 60 Hz: 11 W Rated rotational speed (Nominal value) 50 Hz: 2550 r/min 60 Hz: 3050 r/m...
...ated current (Nominal value) 50 Hz: 0.090 A 60 Hz: 0.075 A Rated input (Nominal value) 50 Hz: 7 W 60 Hz: 6 W Rated rotational speed (Nominal value) 50 Hz: 1900 r/min 60 Hz: 2200 r/mi...
... Release voltage (Reset voltage) 15 % min. Maximum voltage 110 % Power consumption Approx. 0.53 W Contact Contact rated load 250 VAC 10 A (Resistive load) 250 VAC 7.5 A (Inductive load (cosφ ...
... Release voltage (Reset voltage) 15 % min. Maximum voltage 110 % Power consumption Approx. 0.53 W Contact Contact rated load 250 VAC 10 A (Resistive load) 250 VAC 7.5 A (Inductive load (cosφ ...
... Release voltage (Reset voltage) 15 % min. Maximum voltage 110 % Power consumption Approx. 0.53 W Contact Contact rated load 250 VAC 10 A (Resistive load) 250 VAC 7.5 A (Inductive load (cosφ ...
... Release voltage (Reset voltage) 15 % min. Maximum voltage 110 % Power consumption Approx. 0.53 W Contact Contact rated load 250 VAC 10 A (Resistive load) 250 VAC 7.5 A (Inductive load (cosφ ...
... Release voltage (Reset voltage) 15 % min. Maximum voltage 110 % Power consumption Approx. 0.53 W Contact Contact rated load 250 VAC 10 A (Resistive load) 250 VAC 7.5 A (Inductive load (cosφ ...
... Release voltage (Reset voltage) 15 % min. Maximum voltage 110 % Power consumption Approx. 0.53 W Contact Contact rated load 250 VAC 10 A (Resistive load) 250 VAC 7.5 A (Inductive load (cosφ ...
...10 A Maximum switching power 2500 VA (Resistive load) 1875 VA (Inductive load (cosφ = 0.4)) 300 W (Resistive load) 150 W (Inductive load (L/R = 7 ms)) Contact form SPDT Contact metho...