IAグローバル検索 |
...定) 8 ON设定工具有效 1234 ON 12345678 ON 12345678 ON DIP-SW 1 2 24V 24V 0V: 0V MUTE B MUTE A: *1 S1 S2 KM1, KM2 M: 3 - - - PNP - 24V Active *1. EDM F3SG-RA单套(使用PNP输出) [DIP-SW可设定] - ...
https://www.fa.omron.com.cn/data_pdf/mnu/f3sg-_ra____-___inst-8400219-9e.pdf
...E B: Pink MUTE A: Gray RESET: Yellow *2 F39-JGA-L F39-JGA-D S1 Power Supply +24 VDC 0 VDC KM2 KM1 S4 S5 S2 S3 *3 IN PLC *4 S1: Test Switch (Connect the line to 0 V if this switch is not req...
https://www.fa.omron.com.cn/data_pdf/mnu/f3sg-_raseries(quickinstallationmanual)_inst-7999687-9h.pdf
...sabled, Manual Reset Mode, External Test in 24 V Active (used), Muting disabled and PNP Outputs KM1, KM2: Safety relay with forcibly guided contacts (G7SA) M: 3-phase motor +24 VDC (Brown) No...
https://www.fa.omron.com.cn/data_pdf/mnu/f3sg-_rr_seies(quickinstallationmanual)_inst-9308038-0d.pdf
...tput 5-4. EDM used, manual reset mode, external test used, muting function not used, NPN output KM1 KM2 S *1 *1 *2 1S2 S1 S2 KM1, KM2 K1 : External test switch (connect to 0 V if a s...
...V (Blue) Auxiliary output (Yellow) Safety output 1 (Black) Safety output 2 (White) Shield S1 S2 KM1, KM2 K1 : External test switch (connect to 0 V if a switch is not required) : Lockout reset...
...V (Blue) Auxiliary output (Yellow) Safety output 1 (Black) Safety output 2 (White) Shield S1 S2 KM1, KM2 K1 : External test switch (connect to 24 V if a switch is not required) : Lockout rese...
...V (Blue) Auxiliary output (Yellow) Safety output 1 (Black) Safety output 2 (White) Shield S1 S2 KM1, KM2 K1 : External test switch (connect to 0 V if a switch is not required) : Lockout reset...
...注1)微少負荷用スイッチをご使用下さい。 0 V 電源 2章配線と取りつけ A-19 形F3SP-B1Pとの組み合わせ時 KM1 KM2 S2 投光器受光器 S1:外部テストスイッチ S2:インターロック/ロックアウトリセッ...
https://www.fa.omron.com.cn/data_pdf/mnu/f3sn-b_scee-717.pdf
...通常動作を、短絡時に外部診断を行います。 S1:非常停止スイッチ S2:リセットスイッチ S3:外部テストスイッチ KM1,KM2:マグネットコンタクタ M:3相モータ KM1 KM2 フィードバックループ投光...
https://www.fa.omron.com.cn/data_pdf/mnu/g9sa-300-sc_inst-0622118-6e.pdf
...)の動作表示のどちらかが点灯しない外部接続保護素子 (ヒューズ等)の故障 5 7 K1、K2 a接点 K1、K2 b接点 KM1、KM2 b接点 KM1、KM2 a接点リミットスイッチS1、S2 ●G9SA-301リミットスイッチ2ch...
.... b接点*2) 補助接点 1 2 3 4 1.8VA以下2.8VA以下3.5VA以下 5 6 7 K1、K2 a接点 K1、K2 b接点 KM1、KM2 b接点 KM1、KM2 a接点リミットスイッチS1、S2 ●G9SA-301リミットスイッチ2ch入力/オー...
https://www.fa.omron.com.cn/data_pdf/mnu/g9sa-301_-501_-321-t__-th301(ac_dc24v)_inst-0622108-9l.pdf
...レーユニット外部の接続と動作チャートは、形G9SB-200-D/301-Dと同じです。 *33-34、41-42があるのは、形G9SB-301-Dです。 ** S1 KM1 KM2 E1 KM1 KM2 M K1 K2 K1 K1 K2 K2 K1 a a + - TH SA A1...
https://www.fa.omron.com.cn/data_pdf/mnu/g9sb-200_-__g9sb-301_-__g9sb-3010_inst-0631549-0j.pdf
... T33 13 23 安全输出 (瞬时) 14 24 T21 T22 复位/反馈输入安全输入1 内部电源电路安全输入2 T31 X1 辅助输出 KM1 KM2 24V PLC等 S1 KM2 KM1 反馈、回路 S2 M KM2 KM1 S1 KM1、K...
https://www.fa.omron.com.cn/data_pdf/mnu/g9se-201_-401_-221-t__inst-2277975-8e.pdf
...itch inputs / Manual reset> A1 A2 T11 T12 T32 T33 13 23 14 24 T21 T22 T31 X1 24V PLC etc. M KM2 KM1 S1 S3 M :Safety limit switch :Contactor :3-phase motor Device Guard lock safety door switc...
https://www.fa.omron.com.cn/data_pdf/mnu/g9se-__1(-t_)_inst-4022078-4e.pdf
...Si19 T0 T5 V2 G2 So0 So7 O0 O3 L L L L ●I/O接线例:紧急停应用手动复 DC24V V1 G1 Si0 Si1 Si2 Si3 KM1-NC KM2-NC KM1 KM2 Reset Estop M KM1 KM2 G9SP V2 G2 So0 So1 T1 T2 T3 T0 4....
https://www.fa.omron.com.cn/data_pdf/mnu/g9sp-n10s_n10d_n20s_inst-2139479-8c.pdf
...emergency stop switch input / Manual reset) G9SX-AD322-T15 Control circuit Timing chart KM2 KM4 KM1 Feedback Loop +24V 12 22 11 21 +24V KM1 KM2 Motor controller (Operation command) K...
https://www.fa.omron.com.cn/data_pdf/mnu/g9sx-ad322-t_-__bc202-__inst-0631677-2g.pdf
...4 L1 X1 X2 T11 A1 T12 T21 T22 T31 T32 T33 Y1 T41 T42 G9SX-AD322-T15 Control circuit 时序图 KM2 KM4 KM1 反馈电路+24V 12 11 +24V KM1 KM2 KM3 KM4 关延时间紧急停开关S1 马达作指 S34 M1 KM...
https://www.fa.omron.com.cn/data_pdf/mnu/g9sx-ad322-t_-__bc202-_inst-2139836-0c.pdf
...A1 T12 T21 T22 T31 T32 T33 Y1 T41 T42 T51 T52 G9SX-ADA222-T150 Control circuit Timing chart KM2 KM1 Feadback Loop +24V 12 11 +24V KM1 KM2 Off-deley time Emargency stop switch S1 Oper...
https://www.fa.omron.com.cn/data_pdf/mnu/g9sx-ada222-t_-__inst-0631702-7f.pdf
...2 L2 T11 A1 T12 T21 T22 T31 T32 T33 Y1 T41 T42 T51 T52 G9SX-ADA222-T150 Control circuit 时序图 KM2 KM1 反馈电路 +24V 12 11 +24V KM1 KM2 关延迟时间紧急停止开关S1 紧急停止开关操作电动...
https://www.fa.omron.com.cn/data_pdf/mnu/g9sx-ada222-t_-__inst-2166128-1b.pdf
...の設定時間が適用されます。 S14 A2 S24 S34 S44 S54 L1 X1 X2 T11 A1 T12 T21 T22 T31 T32 T33 Y1 T41 T42 KM2 KM6 KM1 +24V +24V フィードバック・ループ +24V KM1 KM5 KM6 KM2 KM3 KM4 オフデ...
https://www.fa.omron.com.cn/data_pdf/mnu/g9sx-ex401-__ex041-t-__inst-0631678-0g.pdf