...or relay unit Wiring When External Device Monitoring Function Is Not Used p.18 OUT PLC IN S1 S2 KM1 KM2 KM1 KM2 E1 +24VDC 0V M KM2 KM1 KM3 Emitter Receiver Communication lin...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-722n_eng_f3sj-a.pdf
...set mode p.8 - Wiring when external device monitoring function is not used p.8 N.C. (Red) S1 S2 KM1 KM2 KM1 KM2 E1 +24V DC 0V M KM2 KM1 Emitter Receiver - Manual reset mode ...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-727f-1_eng_f3sr-430b.pdf
...V (Blue) Power supply +24 VDC (Gray) Communication line (+) (Pink) Communication line (-) S1 *1 KM1 KM2 S1 : External test/lockout reset switch (connect to 0 V if a switch is not require...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-732k_eng_f3sj-e____p25_b____p25.pdf
... 0 V (Blue) Power supply +24 VDC (Gray) Communication line (+) (Pink) Communication line (-) S1 KM1 KM2 S1 : External test/lockout reset switch (connect to 24 V if a switch is not requir...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-733j_eng_f3sj-e____n25_b____n25.pdf
... Safety output 2 (White) Shield Open Open Open Power supply +24 VDC F39-JD A-L F39-JD A-D S1 S2 KM1, KM2 K1 *1. Use a switch for small loads (input specifications: 24 V, 1.0 mA max.). *2. F3S...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-734j_eng_f3sj-b____p25-01ts.pdf
...V (Blue) Auxiliary output (Yellow) Safety output 1 (Black) Safety output 2 (White) Shield S1 S2 KM1, KM2 K1 : External test switch (connect to 24 V if a switch is not required) : Lockout rese...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-735j_eng_f3sj-b____n25-01t.pdf
... Safety output 2 (White) Shield Open Open Open Power supply +24 VDC F39-JD A-L F39-JD A-D S1 S2 KM1, KM2 K1 : External test switch (connect to 0 V if a switch is not required) : Lockout reset...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-736j_eng_f3sj-b____p25-02ts.pdf
...用互锁功能 -自动复位模式的配线p.28 -未使用外部设备监控功能时的配线p.28 PLC䕧ܹ* OUT PLC IN S1 S2 KM1 KM2 E1 +DC24V 0V M KM2 KM1 KM4 F39-JC A-L F39-JC A-D ᡩܝ఼ফܝ఼ 䗮ֵ㒓(+)˄♄㡆˅ 䗮ֵ㒓(-)...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-c-718b_f3sj.pdf
...止按钮开关应用示意图安全类别/PL安全设备停止类别复位方法相当于4/PLe紧急停止按钮开关0手册接线示例 M KM1 KM2 KM1 KM1 KM2 KM2 S1 S2 IN0 IN1 IN2 IN3 IN4 IN5 IN6 IN7 T0 T1 T2 T3 T...
...的产品。 •自动复位模式时 •手动复位模式时 F3SG-SRA○ F3SG-SRB○ PNP/NPN选择规定电压 PNP Vs-3V~Vs NPN 0V~3V DC24V 0V PNP KM1, KM2:外部继电器 *设置锁定复位开关时,请通过b接点开关在虚线部进行接...
https://www.fa.omron.com.cn/data_pdf/mnu/sgfm-cn5-726a_f3sg-_sr_.pdf
...xample of Safety Circuit Fig. 5-3 Basic Connection with Single OS32C unit KM1KM2 S2 S3 S2 S1 M1 KM1 KM2 0V E1 0VDC (Brown) Standby input (Violet)Zone Select 1 (Orange/White)Zone Select 2 (Ora...
https://www.fa.omron.com.cn/data_pdf/mnu/z296-e1-17_os32c.pdf
...Auto Reset mode F3SG-RA Series X F3SG-RE Series PNP/NPN Voltage PNP Vs-3 V to Vs NPN 0 V to 3 V KM1, KM2: External device * Also used as EDM input line. When using a lockout reset switch, con...
https://www.fa.omron.com.cn/data_pdf/mnu/z352-e1-11_f3sg-_r_.pdf
...g Manual for the location of the jumpers. Fig. 3-11 UMA with MC3 (Manual Reset Mode) 24 VDC MC3 KM1 KM2 M UMA UMA Blue White Black Brown Blue White Black Brown Power supply Control Circuit 13...
...ch (When the switch is not required, connect the EDM input to 24V (PNP) via the external relay (KM1, KM2) (NC contact) or 0V (NPN). KM1, KM2: External device S1 S1 KM1 F39-J...
https://www.fa.omron.com.cn/data_pdf/mnu/z380-e1-04_f3sg-4ra____-25-01ts.pdf
...line. Basic wiring diagram •In Auto Reset mode PNP/NPN Voltage PNP Vs-3 V to Vs NPN 0 V to 3 V KM1, KM2: External device * Also used as EDM input line. When using a lockout reset switch, con...
https://www.fa.omron.com.cn/data_pdf/mnu/z383-e1-04_f3sg-_rr.pdf
.... Input External Connection ON Vs-3 V to Vs OFF 0 V to 1/2 Vs, or open S1: Lockout reset switch KM1, KM2: External device *Also used as lockout reset line KM1 F39-JDA-D KM2 Receive...
https://www.fa.omron.com.cn/data_pdf/mnu/z391-e1-03_f3sg-4ar____-25-02ts.pdf
...fety device Stop category Reset Equivalent to 4/PLe Emergency stop pushbutton 0 Manual Wiring M KM1 KM2 KM1 KM1 KM2 KM2 S1 S2 IN0 IN1 IN2 IN3 IN4 IN5 IN6 IN7 T0 T1 T2 T3 T4 ...
https://www.fa.omron.com.cn/data_pdf/mnu/z400-e1-09_gi-s.pdf
...-PGA-C 3 F3SG-SRB 3 F3SG-PGA-L 3 PNP/NPN Voltage PNP Vs-3 V to Vs NPN 0 V to 3 V +24 VDC 0V PNP KM1, KM2: External device KM1 KM2 0V +24 VDC NPN KM1 KM2 24V/0V (Brown) RESET...
https://www.fa.omron.com.cn/data_pdf/mnu/z405-e1-08_f3sg-sr_pg.pdf
...k release enable signal S5 S4 Feedback loop Emergency Stop Switch Guard lock Safety-door Switch KM1 KM2 S1 S2 KM1 +24V Open Condition monitoring of Safety-door Switch Guard M1 G9SX-B...
https://www.omron-ap.co.in/data_pdf/cat/a22tk_a189-e1_9_6_csm2088.pdf
...abling Grip Switch. 8 A4EG Feedback loop Lock release enable signal S5 Emergency Stop Switch S4 KM1 KM2 S1 Guard lock Safety-door Switch S2 KM1 +24V Open KM2 A1 T11 T12 T21 T22 T31 T...
https://www.omron-ap.co.in/data_pdf/cat/a4eg_ds_e_9_1_csm000001266.pdf