| IAグローバル検索 |
... be connected for a CJ2H-CPU6@-EIP or CJ2M-CPU3@ CPU Unit. *4. Increases by 0.15 A/Unit when an NT-AL001 RS-232C/RS-422A Link Adapter is used. Increases by 0.04 A/Unit when a CJ1W-CIF11 RS-42...
https://www.fa.omron.com.cn/data_pdf/cat/cj2h_cj2m_p059-e1_17_27_csm1004123.pdf
...,单CPU系统) :505(W)×132(H)×123(D) *2 32可编程控制器CS1D CPU单元型号一览 *1.这些值包含所连编程器的电流消耗。 *2.使用NT-AL001 Link Adapter时,每个额外消耗0.15A。 CS1D CPU单元 (用于双CPU系统) ...
https://www.fa.omron.com.cn/data_pdf/cat/cs1d-cpu__s_bc082s_etn21d_sbca-cn5-014_9_11.pdf
...考手册的指示进行。 ●千万不要将CPU单元上RS-232口上的引脚6(5V电源)与其它设备连接,除非设备上用了转换适配器CJ1W-CIF11/NT-AL001、可编程终端NV3W-M□20L。 否则会损坏外部设备或CPU单元。 ●请使用各单...
...t pin 6 (+5V) on the RS-232C Option Board on the CPU Unit to any external device other than the NT-AL001 or CJ1W-CIF11 Conversion Adapter or NV3W-Mƶ20L Programmable terminal. The external dev...
...current protection. •Do not use the +5 V output from the CP1W-CIF01 for anything other than the NT-AL001. •A G9SP-series Controller has two sets of power supply terminals, one for the main po...
https://www.fa.omron.com.cn/data_pdf/mnu/g9sp-n10s_n10d_n20s_inst-2114042-7f.pdf
...cted and the condi- tions at the operation site. Reference: When using an RS-232C/422A Adapter (NT-AL001) with the host link or NT link (1:1) communications method, RS-485 cannot be used. The...
https://www.fa.omron.com.cn/data_pdf/mnu/v062-e1-06_nt31_31c_setup.pdf
...cted and the condi- tions at the operation site. Reference: When using an RS-232C/422A adapter (NT-AL001) with the host link or NT link (1:1) communications method, RS-485 cannot be used. The...
https://www.fa.omron.com.cn/data_pdf/mnu/v063-e1-05_nt631_631c_setup.pdf
...female) RS-232C only (The NT Support Tool and bar code readers can be connected here, as can an NT-AL001 RS-232C/RS-422A Link Adapter.) •Serial port B: D-Sub 9-pin connector (female) RS-232C ...
https://www.fa.omron.com.cn/data_pdf/mnu/v069-e1-03_nt21_nt31_nt631.pdf
...A/485) to send/ receive communications frames and other data via the BASIC program. Note Use an NT-AL001 Link Adapter (RS-232C to RS-422/485) to connect more than one terminal/device to an RS...
https://www.fa.omron.com.cn/data_pdf/mnu/w306-03_c200h-asc11_21_31.pdf
...的规格制作电缆。 使用市售电缆可能会损坏外部设备或CPU单元。 ·切勿将CPU单元RS-232C端口上的引脚6(5V电源)连接到除NT-AL001链接适配器、CJ1W-CIF11 转换器及可编程终端(NV3W-M@20L)以外的任何设备,否则...
...的规格制作电缆。 使用市售电缆可能会损坏外部设备或CPU单元。 ·切勿将CPU单元RS-232C端口上的引脚6(5V电源)连接到除NT-AL001链接适配器、CJ1W-CIF11 转换器及可编程终端(NV3W-M@20L)以外的任何设备,否则...
........................................................................................ 3-7 3-2-8 NT-AL001 Link Adapter Settings....................................................................
https://www.fa.omron.com.cn/data_pdf/mnu/w494-e1-04_cj1w-scu_2.pdf
...SCU21:110g以下 SCU31:110g以下 SCU41:110g以下 SCU22:160g以下 SCU32:120g以下 SCU42:140g以下注:串行通信单元自身的消耗电流。 使用NT-AL001时,由串行通信单元供给NT-AL001的电源。 x:...
https://www.fa.omron.com.cn/upload/alternative/2022041CC.PDF
...t pin 6 (+5V) on the RS-232C Option Board on the CPU Unit to any external device other than the NT-AL001 or CJ1W-CIF11 Conversion Adapter. The external device and the CPU Unit may be damaged....
https://www.omron-ap.co.in/data_pdf/mnu/cpseries(safetyprecautions)_inst-1118339-0e.pdf
...t pin 6 (+5V) on the RS-232C Option Board on the CPU Unit to any external device other than the NT-AL001 or CJ1W-CIF11 Conversion Adapter. The external device and the CPU Unit may be damaged....
https://www.omron-ap.co.in/data_pdf/mnu/cpseries(safetyprecautions)_inst-1131255-6b.pdf
...ᣦ♧ࡉࢀࡓ᪉ἲ࡛⾜ࡗ࡚ࡃࡔࡉ࠸ࠋ ەCPU ࣘࢽࢵࢺ╔ࡋࡓ RS-232C ࢜ࣉࢩ࣮ࣙࣥ࣎ࢻࡢ 6 ␒ࣆࣥ㸦+5V 㟁※㸧ࡣࠊኚ ࢲࣉࢱ ᙧ CJ1W-CIF11/ᙧ NT-AL001 ௨እࡢእ㒊ᶵჾࡣ᥋⥆ࡋ࡞࠸࡛ࡃࡔࡉ࠸ࠋእ 㒊ᶵჾ࠾ࡼࡧ CPU ࣘࢽࢵࢺࡀᨾ㞀ࡍࡿᜍࢀࡀ࠶ࡾࡲࡍࠋ ە᥋⥆ࢣ࣮ࣈࣝࡣྛࣘ...
https://www.omron-ap.co.in/data_pdf/mnu/cpseries(safetyprecautions)_inst-1131256-4b.pdf
...ᣦ♧ࡉࢀࡓ᪉ἲ࡛⾜ࡗ࡚ࡃࡔࡉ࠸ࠋ ەCPU ࣘࢽࢵࢺ╔ࡋࡓ RS-232C ࢜ࣉࢩ࣮ࣙࣥ࣎ࢻࡢ 6 ␒ࣆࣥ㸦+5V 㟁※㸧ࡣࠊኚ ࢲࣉࢱ ᙧ CJ1W-CIF11/ᙧ NT-AL001ࠊࣉࣟࢢ࣐ࣛࣈࣝࢱ࣮࣑ࢼࣝᙧ NV3W-Mڧ20L ௨እࡢ እ㒊ᶵჾࡣ᥋⥆ࡋ࡞࠸࡛ࡃࡔࡉ࠸ࠋእ㒊ᶵჾ࠾ࡼࡧ CPU ࣘࢽࢵࢺࡀᨾ㞀...
https://www.omron-ap.co.in/data_pdf/mnu/cpseries(safetyprecautions)_inst-2104744-3c.pdf
...t pin 6 (+5V) on the RS-232C Option Board on the CPU Unit to any external device other than the NT-AL001 or CJ1W-CIF11 Conversion Adapter or NV3W-Mƶ20L Programmable terminal. The external dev...
https://www.omron-ap.co.in/data_pdf/mnu/cpseries(safetyprecautions)_inst-2104888-1c.pdf
...で行ってください。 ●CPU ユニットに装着した RS-232C オプションボードの 6 番ピン (+5V 電源) は、変換アダプタ 形CJ1W-CIF11/形NT -AL001 以外の外部機器には接続し ●l ithium1次電池( 過塩素塩酸含有...
https://www.omron-ap.co.in/data_pdf/mnu/cpseries(safetyprecautions)_inst-4074765-0e.pdf
...urrent protection. • Do not use the +5 V output from the CP1W-CIF01 for anything other than the NT-AL001. • A G9SP-series Controller has two sets of power supply terminals, one for the main p...
https://www.omron-ap.co.in/data_pdf/mnu/g9sp-n10s_n10d_n20s_inst-2114042-7f.pdf