Primary Contents

IAグローバル検索結果

国/地域選択

IAグローバル検索
結果 721 - 7401242
PDF[W304-E1-05] C200HW-COM01/COM02-V1 to C200HW-COM06...

...S-232C port to enable data transfer via NT Link commands. CPU Unit Communications Board RS-232C NT-AL001 Link Adapter (RS-232C to RS-422A/485 conversion) PT RS-232C PT PT PT Protocol Macros D...

https://www.fa.omron.co.jp/data_pdf/mnu/w304-e1-05_c200hw_com01_com02_v1-06_v1.pdf

PDF[W318-E1-05] SRM1(-V2) Master Control Units Operat...

...R 6 6 – SG 7 7 – – 8 8 – – 9 9 SG ER 20 Hood 25 Section Wiring and Connections 3-4 RS-232C Port NT-AL001 1:1 Connection Ribbon line (red) Ribbon line (black) Signal Pin No. Pin No. Signal – 1...

https://www.fa.omron.co.jp/data_pdf/mnu/w318-e1-05_srm1_v2.pdf

PDF[W479-E1-11] CP1E-E[][](S)D[]-[]/N(A)[][]D[]-[]/N[...

... connect pin 6 to any other device. • RS-422A CJ1W-CIF11 Conversion Adapter • RS-232C / RS-422A NT-AL001 Conversion Adapter • NV3W-M20L Programmable Terminal • Use the cables that are specif...

https://www.fa.omron.co.jp/data_pdf/mnu/w479-e1-11_cp1e.pdf

PDF[W494-E1-04] CJ1W-SCU22/SCU32/SCU42 Serial Communi...

.............................................................................................. 3-7 NT-AL001 Link Adapter Settings....................................................................

https://www.fa.omron.co.jp/data_pdf/mnu/w494-e1-04_cj1w-scu_2.pdf

PDF[W578-E1-14] NX1P2-[][][][][][](1) CPU Unit User's...

... power supply terminal, it cannot be connected to external converters such as an CJ1W-CIF11 and NT-AL001, or an NV3W-M£20L Programmable Terminal. The terminal block is not removable. RS-422A/...

https://www.fa.omron.co.jp/data_pdf/mnu/w578-e1-14_nx1p2.pdf

PDFCSM_CJ1W-CIF11_DS_C_2_1 1 400-820-4535 www.fa.omro...

...2. CJ1W-CIF11是非绝缘型转换器,因此整个传送路径的总传送距离不能超过50m。 如果总传送距离大于50米,请使用绝缘型NT-AL001,请勿使用CJ1W-CIF11。 如果仅使用NT-AL001,则整个传送路径的总传送...

https://www.fa.omron.com.cn/data_pdf/cat/cj1w-cif11_ds_c_2_1.pdf

PDFCSM_CJ1W-CIF11_DS_E_2_2 1 SYSMAC Option RS-422A Co...

...on path is 50 m max. If the total transmission distance is greater than 50 m, use the insulated NT-AL001, and do not use the CJ1W-CIF11. If only the NT-AL001 is used, the total trans...

https://www.fa.omron.com.cn/data_pdf/cat/cj1w-cif11_ds_e_2_2_csm1972.pdf

PDFCSM_CJ1W-SCU_DS_C_9_2 1 400-820-4535 www.fa.omron....

...໛ 䗮⫼໪䚼䆒໛ ᮴ण䆂 ⏽ᑺ᥻ࠊ఼ ᱎ㛑Ӵᛳ఼ CPUऩܗ ৃ㓪⿟㒜ッ(PT) 㓪⿟䆒໛ Modbus-RTUЏキ ˄Ϟԡ䅵ㅫᴎ˅ RS-232C/RS-422A䗖䜡఼ NT-AL001 І㸠㔥݇ ˄Ϟԡ䫒᥹(FINS)˅ CJ㋏߫᥻ࠊ఼ ˄Ϟԡ䫒᥹⃵キ˅ І㸠㔥݇ (Compoway/F) 2 400-820-4535 www.f...

https://www.fa.omron.com.cn/data_pdf/cat/cj1w-scu_ds_c_9_2.pdf

PDFCSM_CJ1W-SCU_DS_E_9_4 1 CJ-series Serial Communica...

...ack or Expansion Racks to create systems with up to 32 serial communications ports. •Connect an NT-AL001 RS-232C/RS-442A Link Adapter to the RS-232C port to enable 1:N communications. •With t...

https://www.fa.omron.com.cn/data_pdf/cat/cj1w-scu_ds_e_9_4_csm2151.pdf

PDFCSM_CJ2H-CPU_DS_C_10_3 1 400-820-4535 www.fa.omron...

...类2产品),CU:cUL,N:NK、L:Lloyd和CE:EC指令。 •有关这些标准的详细信息和适用条件,请联系欧姆龙代表处。 ■CJ2H CPU单元 使用NT-AL001 RS-232C/RS-422A适配器时,每个适配器增加0.15A。 使用CJ1W-CI...

https://www.fa.omron.com.cn/data_pdf/cat/cj2h-cpu_ds_c_10_3.pdf

PDFCSM_CJ2H-CPU_DS_E_10_3 1 CJ-series CJ2H CPU Units ...

...t recent applicable standards for each model. CJ2H CPU Units *Add 0.15 A per Adapter when using NT-AL001 RS-232C/RS-422A Adapters. Add 0.04 A per Adapter when using CJ1W-CIF11 RS-422A Adapter...

https://www.fa.omron.com.cn/data_pdf/cat/cj2h-cpu_ds_e_10_3_csm2011.pdf

PDFCSM_CJ2M-CPU3__-CPU1_-MD21__DS_E_12_7

...mmunications Option Boards (CP1W-CIF01/CIF11/CIF12-V1), respectively. Add 0.15A/Unit when using NT-AL001 RS-232C/RS-422A Adapters. Add 0.04A/Unit when using CJ1W-CIF11 RS-422A Adapters. Add 0...

https://www.fa.omron.com.cn/data_pdf/cat/cj2m-cpu3__-cpu1_-md21__ds_e_12_7_csm2201.pdf

PDF1 CP series CP1H CPU Unit CP1H-X@@D@-@/CP1H-Y@@D@-...

...or CPU Bus Units can be connected. * The current consumption increases by 0.15 A/Adapt- er when NT-AL001 Link Adapters are used. Unit name Model 5 V Current consumption (A) Analog Input Units...

https://www.fa.omron.com.cn/data_pdf/cat/cp1h_p080-e1_11_13_csm1004100.pdf

PDF1 CP系列CP1H CPU单元 CP1H-X□□D□-□/CP1H-Y□□D□-□

...ਦᮦȾӻਥֵ⭞1ṯI/O䘔᧛⭫㔼Ⱦ ᴶཐਥԛ䘔᧛2ਦ CJ㌱ࡍⲺ儎ࣕ㜳 I/OঋݹȽCPU儎 ࣕ㜳ঋݹȾ 注.包括停产产品。 *使用链接适配器NT-AL001时,每台增加0.15A。 单元名称型号 5V 消耗电流(A) 模拟输入单元 CJ1W-AD042 0.52A CJ1W-AD081-...

https://www.fa.omron.com.cn/data_pdf/cat/cp1h_sbca-cn5-083_11_10.pdf

PDFProgrammable Controller CS1D Duplex System

...PU Units *1.These values include the current consumption of a connected Programming Console. *2.NT-AL001 Link Adapters consume an additional 0.15 A each when used. CS1D CPU Unit (For a Duplex...

https://www.fa.omron.com.cn/data_pdf/cat/cs1d-cpu__s_bc082s_etn21d_r103-e1_9_22_csm1004122.pdf

PDFProgrammable Controllers

...CS1 CPU Units *These values include the current consumption of a connected Programming Console. NT-AL001 Link Adapters consume an additional 0.15 A each when used. Basic Configuration Units C...

https://www.fa.omron.com.cn/data_pdf/cat/cs1g_cs1h_cs1w_cs1d_p047-e1_14_15_csm1004120.pdf

PDF顺序控制和过程控制的完美融合 适用于各种应用领域的理想控制系统

...、 任意时间下RAM数据的备份/改写对CPU单元循环时间的影响最大0.8ms最大25ms *30.2ms 消耗电流(电源供电) DC5V 220mA 注.使用NT-AL001连接适配器时会增加150mA。 DC5V 360mA以下注.使用NT-AL001...

https://www.fa.omron.com.cn/data_pdf/cat/cs1w_p051-cn5-06.pdf

PDFCJ1 CJ1扩展了设备控制的领域! 可编程控制器 灵活! 小巧!

...时已符合PLC的适用标准,即EN61131-2 标准。 26可编程控制器CJ1 种类 n CJ1 CPU单元注1.电流消耗包含编程器电流。 使用NT-AL001 RS-232C/RS-232A适配器时,每个适配器增加0.15A。 使用CJ1W-CIF11 RS-422A适...

https://www.fa.omron.com.cn/data_pdf/cat/csm_cj1g_cj1h_cj1w_cj1m_ca_c_10_6.pdf

PDF1 Machine Automation Controller NX1P

... power supply terminal, it cannot be connected to external converters such as an CJ1W-CIF11 and NT-AL001, or an NV3W-M…20L Programmable Terminal. 2. The terminal block is not removable. Machi...

https://www.fa.omron.com.cn/data_pdf/cat/nx1p_p116-e1_9_8_csm1055399.pdf

PDF1 400-820-4535 www.fa.omron.com.cn免费

...地- DR数据集准备就绪输入 RS发送请求输出 CS可发送输入 SHLD屏蔽- 注1.不带+5V电源端子,因此无法连接CJ1W-CIF11和NT-AL001等外部转换设备和可编程终端NV3W-M□20L。 2.无法拆装端子台。 机械自动化控制...

https://www.fa.omron.com.cn/data_pdf/cat/nx1p_sbca-cn5-105_6_16.pdf

結果 721 - 7401242

国/地域選択

Related Contents