IAグローバル検索 |
...te 1. The Open Network Controller does not have a 5-V output. Provide a 5-V power supply to the NT-AL001-E Link Adapter from an external source. 2. This example shows the connector pin layout...
https://www.fa.omron.com.cn/data_pdf/mnu/v228-e1-02_itnc-epx-drm.pdf
...via an RS-232C port to enable data transfer via NT Link commands. CPU Unit Communications Board NT-AL001 Link Adapter (RS-232C to RS-422A/485 conversion) RS-232C RS-232C PT PT PT PT Protocol ...
https://www.fa.omron.com.cn/data_pdf/mnu/w304-e1-05_c200hw_com01_com02_v1-06_v1.pdf
...––– SG 7 8 9 1 2 3 4 5 6 7 8 9 – SD RD RS CS –– SG RS-232C Port Pin No. Signal – Pin No. Signal NT-AL001 Hood Ribbon line (red) Ribbon line (black) 1:1 Connection 1 2 3 4 5 6 – SD RD RS CS ––...
https://www.fa.omron.com.cn/data_pdf/mnu/w318-e1-05_srm1_v2.pdf
...)中的某一位变为ON。 电缆连接不正确。 RS-422A/485的端口2上的2线制/4 线制选择开关的设定与配线不匹配。 适配器(NT-AL001 等)配线不正确。 检查电缆连接。 将通信板端和最终目的地设备上的终端电阻(终端...
https://www.fa.omron.com.cn/data_pdf/mnu/w344-cn5-12_cx-protocol.pdf
...rts on the Controller Section) to any external device except the CJ1W- CIF11 RS-422A Adapter or NT-AL001 RS-232C/RS-422A Adapter. Doing so may damage the external device or NSJ Controller. •W...
https://www.fa.omron.com.cn/data_pdf/mnu/w452-e1-08_nsj_setup.pdf
... power supply terminal, it cannot be connected to external converters such as an CJ1W-CIF11 and NT-AL001, or an NV3W-M£20L Programmable Terminal. The terminal block is not removable. RS-422A/...
https://www.fa.omron.com.cn/data_pdf/mnu/w578-e1-14_nx1p2.pdf
...wing Adaptors are recommended when converting from RS-232C to RS-422. •Connecting to PLC: OMRON NT-AL001 Link Adaptor •Connecting to computer: OMRON B500-AL004 Link Adapter 4-4-2 Connecting T...
https://www.fa.omron.com.cn/data_pdf/mnu/z152-e1-02_e3x-drt21_srt21_cif11.pdf
... HEAD1 HEAD2 SW SETTING DAT RUN ERR/ALM INH PRPHL COMM BKUP 0 1 2 3 4 0 1 2 5 6 7 8 9 3 4 5 PLC NT-AL001 Converter ID Controller R/W Head DC Workpiece (moving body) PC RS-422A RS-232C RS-422A...
https://www.fa.omron.com.cn/data_pdf/mnu/z194-e1-03_v600-idsc02_04.pdf
...on path is 50 m max. If the total transmission distance is greater than 50 m, use the insulated NT-AL001, and do not use the CJ1W-CIF11. If only the NT-AL001 is used, the total trans...
https://www.omron-ap.co.in/data_pdf/cat/cj1w-cif11_ds_e_2_2_csm1972.pdf
...ck or Expansion Racks to create systems with up to 32 serial communications ports. • Connect an NT-AL001 RS-232C/RS-442A Link Adapter to the RS-232C port to enable 1:N communications. • With ...
https://www.omron-ap.co.in/data_pdf/cat/cj1w-scu_ds_e_9_5_csm2151.pdf
...nks CJ2H-CPU64-EIP 0.016 μs 5V 0.82 * 24 V − CJ2H-CPU66-EIP * Add 0.15 A per Adapter when using NT-AL001 RS-232C/RS-422A Adapters. Add 0.04 A per Adapter when using CJ1W-CIF11 RS-422A Adapter...
https://www.omron-ap.co.in/data_pdf/cat/cj2h-cpu-eip_ds_e_11_4_csm1780.pdf
...s × 4 banks CJ2H-CPU64 0.016 μs 5V 0.42 * 24 V − CJ2H-CPU66 * Add 0.15 A per Adapter when using NT-AL001 RS-232C/RS-422A Adapters. Add 0.04 A per Adapter when using CJ1W-CIF11 RS-422A Adapter...
https://www.omron-ap.co.in/data_pdf/cat/cj2h-cpu_ds_e_10_3_csm2011.pdf
...mmunications Option Boards (CP1W-CIF01/CIF11/CIF12-V1), respectively. Add 0.15A/Unit when using NT-AL001 RS-232C/RS-422A Adapters. Add 0.04A/Unit when using CJ1W-CIF11 RS-422A Adapters. Add 0...
https://www.omron-ap.co.in/data_pdf/cat/cj2m-cpu3__-cpu1_-md21__ds_e_12_7_csm2201.pdf
...ta Storage Unit CJ1W-SPU01-V2 0.56 A * The current consumption increases by 0.15 A/Adapter when NT-AL001 Link Adapters are used. 27 CP1H Current Consumption z Based on the current consumption...
https://www.omron-ap.co.in/data_pdf/cat/cp1h_p080-e1_11_13_csm1004100.pdf
...No Yes No No * These values include the current consumption of a connected Programming Console. NT-AL001 Link Adapters consume an additional 0.15 A each when used. 18 Programmable Controllers...
https://www.omron-ap.co.in/data_pdf/cat/cs1g_cs1h_cs1w_cs1d_p047-e1_14_15_csm1004120.pdf
... power supply terminal, it cannot be connected to external converters such as an CJ1W-CIF11 and NT-AL001, or an NV3W-M 20L Programmable Terminal. 2. The terminal block is not removable. 30 Ma...
https://www.omron-ap.co.in/data_pdf/cat/nx1p_p116-e1_9_8_csm1055399.pdf
...See note.) 0.02 0.13 Included in CPU Unit or Expansion Unit. Note: Add 0.15 A per Unit when the NT-AL001-E is connected and 0.04 A when the CJ1W-CIF11 RS-422A Adapter is connected. CJ-series ...
https://www.omron-ap.co.in/data_pdf/cat/p04e-en-03a+cj1+groupcat.pdf
... Units 1, 2, and 3 can be mounted in any order. 2. Only one Expansion Unit can be mounted if an NT-AL001 is connected to the RS-232C port. CPM1A-10CDR-D-V1 CPM1A-20CDR-D-V1 CPM1A-30CDR-D-V1 C...
https://www.omron-ap.co.in/data_pdf/cat/p06e-en-03a+cpm_+groupcat.pdf
... 92 NT2S-SF125B-E NT2S-SF126B-E NT2S-SF127B-E 107 107 93 27 92 Small Function Key Terminals 665 NT-AL001 RS-232C/RS-422A Adapter The NT-AL001 converts signals between RS-232C and RS-...
https://www.omron-ap.co.in/data_pdf/cat/v02e-en-01+nt+groupcat.pdf
...ださい。 配線は指示された方法で行ってください。 CPUユニットのRS-232Cポートの6番ピン(+5V電源)は、変換アダプタ形NT-AL001/形CJ1W-CIF01以外の外部機器には接続しないでください。 外部機器およびCP...
https://www.omron-ap.co.in/data_pdf/mnu/cj1w-pts(safetyprecautions)_inst-1618419-0a.pdf