IAグローバル検索 |
...e Reset Light indicator (red) (Between brown and black) Output transistor Load (e.g., relay) 12 K (External diagnostic input) (Self-diagnostic output) ZD Light indica- tor Stability indicator...
https://www.fa.omron.com.cn/data_pdf/cat/e3s-a_ds_e_13_1_csm1296.pdf
...cator (green) 8 Connector Models E3Z-B66 E3Z-B86 E3Z-B67 E3Z-B87 M8 Pre-wired Connector (E3Z-T@@K-M3J) M12 Pre-wired Connector (E3Z-@@@-M1J) 4 dia. vinyl-insulated round cable with 3 conducto...
https://www.fa.omron.com.cn/data_pdf/cat/e3z-b_ds_e_10_1_csm433.pdf
...39-S65D 1×10mm 2.2m 1.5mφ0.5mm E39-S65E 2×10mm 5m 3.5mφ0.8mm E39-S65F 名称检测距离* 型号数量备注E3Z-R E3Z-R□K E3Z-B□1/-B□6 E3Z-B□2/-B□7 额定值参考值额定值额定值额定值反射板 3m〔100mm〕—2m〔10...
...10 mm 5 m 3.5 m 0.8-mm dia. E39-S65F Name Sensing distance * Model Quantity Remarks E3Z-R E3Z-R@K E3Z-B@1/-B@6 E3Z-B@2/-B@7 Rated value (sensing distance of 15 m) Reference value (sensing dis...
...10 mm 5 m 3.5 m 0.8-mm dia. E39-S65F Name Sensing distance * Model Quantity Remarks E3Z-R E3Z-R@K E3Z-B@1/-B@6 E3Z-B@2/-B@7 Rated value (sensing distance of 15 m) Reference value (sensing dis...
https://www.fa.omron.com.cn/data_pdf/cat/e3z_ds_e_18_9_csm438.pdf
...开的最小距离。 人体垂直进入传感器的检测区域时,安全距离可按下示的方法计算。 安全距离(S)=进入检测区域的速度(K) ×设备和传感器的总响应时间(T) +由传感器最小检测物体直径计算的添加距离 (C) ...
https://www.fa.omron.com.cn/data_pdf/cat/e3zs_e3fs_ds_c_1_1.pdf
...+400ć 0̚+350ć 0̚+300ć E52Z-CA2GV E52Z-CA1D-40 य़ᓣ៤ᔶ ᴎ⫼⛁⬉ي ᏺ㶎ϱ ᇐ㒓Ⳉߎൟ ൟো㾖⏽ᑺ㣗ೈˆܗӊ⾡㉏ㄝ㑻ッᄤ㉏ൟֱᡸㅵⱘᴤ䋼ᮍᓣ K(CA)ㄝ㑻2 ˄0.75㑻˅ ᓩ㒓ⳈߎൟSUS304ഄൟ ൟোᷛޚ ˆ䆺㒚䅶䋻ൟো䇋খ㾕3义ⱘൟো E52Z-ƶƶƶD=ƶƶƶM 1: 1...
https://www.fa.omron.com.cn/data_pdf/cat/e52z_h06z-cn-02.pdf
....a 2h 0.0 0. a 2l 0.0 0. a 0.0 -3 0.a 3h 0.0 0. a 3l 0.0 0.a 1 0. s o k off 0.w t b 2l 0.0 7. a 0.0 -3 7.a 3h 0. 0 7. a 3l 0. 0 7. a 1 7. s o k of f 7. w t b 7.lsp 0.0 7.pid 1 7.s p ...
https://www.fa.omron.com.cn/data_pdf/cat/e5_n_e5_n-h_e5_n-ht_operation_tg_e_4_4_csm1375.pdf
...线性电流输出: 4~20 mA, 0~20 mA脉冲电压输出: 12 VDC, PNP继电器输出:位置比例每行显示位数:5显示行数:3 100~240 VAC, 24 VAC/VDC K, J, T, E, L, U, N, R, S, B, W, Pt100, 1~5 V, 0~5 V, 0~10 V...
https://www.fa.omron.com.cn/data_pdf/cat/e5_r_h121-c1-01.pdf
...点) 4点4点无E5AR-TPR4DF 继电器输出 (开1点+关1点)+电流1点 10点*1 8点RS-485 E5AR-TPRQE3MF-FLK 关于带检验合格证型号 E5AR-K 安装对象型号 E5AR E53-COV14 型号 Y92S-L1 型号 Y92S-P4 型号 Y92H-9 ...
https://www.fa.omron.com.cn/data_pdf/cat/e5ar-t_e5er-t_ca_c_5_1.pdf
...1点、关1点) 4点无DeviceNet E5AR-PR4F-DRT 继电器输出(开1点、关1点)+ 电流(传送)1点 E5AR-PRQ4F-DRT 关于带检验合格证型号 E5AR-K E5AR 8 400-820-4535 www.fa.omron.com.cn咨询电话最新信息免费电...
https://www.fa.omron.com.cn/data_pdf/cat/e5ar_e5er_ca_c_3_1.pdf
...voltage Power consumption 7.5 VA max. Sensor input Models with temperature inputs Thermocouple: K, J, T, E, L, U, N, R, S, or B Platinum resistance thermometer: Pt100 or JPt100 Infrared tempe...
https://www.fa.omron.com.cn/data_pdf/cat/e5cn-fr_h132-e1-01.pdf
...age Power consumption 100 to 240 VAC: 5 VA 24 VAC: 3 VA, 24 VDC: 2 W Sensor input Thermocouple: K, J, L Platinum resistance thermometer: Pt100, JPt100 Thermistor: E52-THE@@ Universal-input (t...
https://www.fa.omron.com.cn/data_pdf/cat/e5cs_ds_e_5_3_csm211.pdf
...电源电压的85%~110% 功率消耗 E5EC-PR-800在AC100~240V时最大6.6VA E5AC-PR-800在AC100~240V时最大7.0VA 传感器输入温度输入型热电偶:K、J、T、E、L、U、N、R、S、B、W或PL II 铂电阻:Pt100或JPt100 ...
https://www.fa.omron.com.cn/data_pdf/cat/e5ec_e5ac-pr-800_h07z-cn5_1_4.pdf
...通注意事项⋯⋯⋯⋯⋯⋯236 技术指南⋯⋯⋯⋯⋯⋯⋯⋯481 用语说明⋯⋯⋯⋯⋯⋯⋯⋯485 相关信息 420 ⬉ᄤ⏽఼ ଚક䗝ᢽ ݅䗮⊼ᛣџ乍 ⬉ᄤ⏽఼ NEO ⬉ᄤ⏽఼R ⬉ᄤ⏽఼K ⬉ᄤ⏽఼S 㒣⌢ൟ ഫൟ Ⳍ݇䆒 䕧ܹ䆒 ᡔᴃᣛफ ᪡㆛ PLCऩܗൟ ᬃᣕ䕃ӊ ⬉ᄤ⏽఼Z 模块型温...
...er Models and Thermocouple Models The applicable standards for the input types are as follows: •K, J, T, E, N, R, S, B: JIS C1602-1995, IEC584-1 •L: Fe-CuNi, DIN 43710-1985 •U: Cu-CuNi, DIN 4...
https://www.fa.omron.com.cn/data_pdf/cat/e5zn_ds_e_3_2_csm218.pdf
...ng Values Set values in each display can be changed by pressing the U and D Keys. Input type: 0 K thermocouple−200 to 1300°C Control method:ON/OFF control Alarm type: 2 upper limit Alarm valu...
https://www.fa.omron.com.cn/data_pdf/cat/e5zn_operation_tg_e_2_2_csm251.pdf
...则可能引发破损或起火。 J连接使用时,请务必连接同一电源,并同时接通电源。 使用不同电源会影响连接时的功能。 K最多连接台数会受到传感头电流消耗值等条件的影响。 连接的放大器台数请勿超过规格。 否则...
https://www.fa.omron.com.cn/data_pdf/cat/e9nc-aa_va_scea-cn5-194_1_1.pdf
...data log viewer, and simple data logging. Compatible models *1 Temperature Controllers E5@R, E5@K, E5ZN, and E5ZE Series (models with communications) Digital Panel Meters K3N@ and K3GN Series...
https://www.fa.omron.com.cn/data_pdf/cat/estt_ds_e_3_1_csm224.pdf
...wall mounting bracket is not provided so that you can design your own wall mounting part. r p R k o l et u l ±15° ±22.5° F3SG-RA Multifunctional Advanced type * Image for illustration purpose...
https://www.fa.omron.com.cn/data_pdf/cat/f3sg-r_f094-e1_12_7_csm1040037.pdf