Primary Contents

IAグローバル検索結果

国/地域選択

IAグローバル検索
結果 841 - 8601344
PDFSafety Relay Unit with negative common (NPN)

...r M is kept OFF until the guard is closed. Timing Chart 23 S2 Limit switches S1 and S2 24 Guard KM1 and KM2 (NO) 11 S1 Feedback loop 12 KM1 KM2 open S1: S2: KM1 and KM2: M: ...

https://www.omron.co.id/data_pdf/cat/g9sa-p_f106-e1_6_2_csm1070131.pdf

PDFSafety Relay Unit G9SA CSM_G9SA_DS_E_11_15

...e motor M is kept OFF until the guard is closed. Timing Chart Limit switches S1 and S2 23 S2 24 KM1 and KM2 (NO) Guard 11 S1 Feedback loop 12 KM1 KM2 S1: S2: KM1 and KM2: M:...

https://www.omron.co.id/data_pdf/cat/g9sa_ds_e_11_15_csm1281.pdf

PDFSafety Relay Unit G9SB CSM_G9SB_DS_E_6_7

...otor M is kept OFF until the guard is closed. Timing Chart S2 Guard Limit switches S1 and S2 S1 KM1 and KM2 (NO) KM1 KM2 Open Feedback loop S1: S2: KM1 and KM2: M: * * A1 A2...

https://www.omron.co.id/data_pdf/cat/g9sb_ds_e_6_7_csm1282.pdf

PDFSafety Relay Unit G9SE Series Compact and Simple S...

...nd reset switch S2 is pressed. Feedback loop S1 Timing Chart S2 Emergency stop switch operation KM1 Emergency stop switch S1 KM2 Reset switch S2 KM1, KM2 NO contact A1 T11 T12 T31 T3...

https://www.omron.co.id/data_pdf/cat/g9se_j198-e1_4_7_csm1040781.pdf

PDFSafety Controller G9SP Software-based standalone c...

...ring Example: Emergency Stop (Dual Channel) with Manual Reset Estop Reset V1 G1 Si0 Si1 So0 So1 KM1 KM2 Si2 Si3 KM1 KM1 KM2 KM2 G9SP V2 DC24V G2 T0 T1 T2 T3 M 21 G9SP Dimens...

https://www.omron.co.id/data_pdf/cat/g9sp_f090-e1_12_9_csm2603.pdf

PDFSafety Controller G9SX Series G9SX-AD@/BC/EX

... reset mode is selected when terminal T33 is shorted to 24 V. Auto reset mode Manual reset mode KM1 Reset switch Conditions for safety outputs turning ON Safety input T51/T52 Logic input 1 OF...

https://www.omron.co.id/data_pdf/cat/g9sx_series_f120-e1_1_5_csm1119023.pdf

PDFSafety Laser Scanner OS32C Compliant with PLd/Cate...

... 8 (Blue/White) *3 S2 Start (Black) *2 S1 Auxiliary output (Blue) Warning output (Red/Black) *1 KM1 KM2 EDM (Brown/White) Safety output B (Yellow) S1 : Start Input (use for releasing lockout)...

https://www.omron.co.id/data_pdf/cat/os32c_z298-e1_14_6_csm2602.pdf

PDFIndustrial Ethernet Cables Catalog

...421-CM1-K 2 XS5W-T421-DM1-K 3 XS5W-T421-EM1-K 5 XS5W-T421-GM1-K 10 XS5W-T421-JM1-K 15 XS5W-T421-KM1-K 0.5 XS5W-T421-BME-K 1 XS5W-T421-CME-K 2 XS5W-T421-DME-K 3 XS5W-T421-EME-K 5 XS5W-T421-GME...

https://www.omron.co.id/data_pdf/cat/xs5_xs2_xs6_g019-e1_12_3_csm2582.pdf

PDF安全上の要点 DST1-MRD08SL-1 2.各部の名称と外形寸法 DC-DCコンバータ

...(形S8□□) L1, L2: 負荷 安全出力と出力のフィードバック入力 DST1-MRD08SL-1 V0 IN0 V1 OUT0 OUT1 G0 T0 G1 C0 C1 KM1 E2 E1 F1 F2 KM1 ※2 KM2 E1: DC24V電源(形S8□□) KM1, KM2: コンタ...

https://www.omron.co.id/data_pdf/mnu/dst1-id_m(r)d_xd__(__)sl-1_inst-1625834-7i.pdf

PDF使用上のご注意 機能 参照マニュアル 製品が動作不能、誤動作、または性能・機器への悪影響を防ぐため、...

...ンターロックリセット/ オーバーライドスイッチ S2:オーバーライドキャンセルスイッチ S3:テストスイッチ KM1、KM2:外部リレー L1:ランプ 受光器の延長ケーブル (片側コネクタまたは両側コネクタ)に接...

https://www.omron.co.id/data_pdf/mnu/f39-gcn5_inst-5633364-3b.pdf

PDF1 各部の名称と外形寸法 (単位:mm) 3 機能 ●NPN仕様 オーバーライド入力対応タイプ 形F...

...外部リレー モニタ入力 または形F3SJ用 PCツール形F39-GWUM ミューティングキーキャップ形F39-CN6 (橙色) 形F3SJ KM1 0V (青) (茶) 電源DC24V 制御出力2 (白) 1 2 3 4 5 制御出力1 (黒) 1 2 3 4 ...

https://www.omron.co.id/data_pdf/mnu/f39-tc5_inst-0126686-6b.pdf

PDFSafety Light Curtain F3SG-4RA□□□□-25-01TS Series h...

...S Quick Installation Manual S1: External test switch(connect to 0V if a switch is not required) KM1, KM2: Safety relay with forcibly guided contacts (G7SA) or magnetic contactor E1: 24VDC pow...

https://www.omron.co.id/data_pdf/mnu/f3sg-4ra____-25-01tsseries(quickinstallationmanual)_inst-5132821-8d.pdf

PDFSafety Light Curtain F3SG-4RA□□□□-25-02TS http://w...

...d (Pink) Not used (Gray) TEST (Black) *1 +24 VDC (Brown) F39-JD□□A-L *4 0 VDC (Blue) [Settings] KM1 KM1 KM2 +24 VDC Power Supply KM2 0 VDC KM1 KM1, KM2: Safety rela...

https://www.omron.co.id/data_pdf/mnu/f3sg-4ra____-25-02ts(quickinstallationmanual)_inst-9309529-9e.pdf

PDFSafety Light Curtain F3SJ-B□□□□□25 Series

...ting function not used, PNP output F39-JDA-L F39-JDA-D (Grey) Communication line (+) KM2 Shield KM1 0 V (Blue) Safety output 2 (White) K1 KM2 Safety output 1 (Black) KM1 Auxiliary ou...

https://www.omron.co.id/data_pdf/mnu/f3sj-b_____25_-e_____25series(quickinstallationmanual)_inst-3126345-4b.pdf

PDFSafety Light Curtain F3SJ-B□□□□N25-01T Series

...t mode, external test used F39-JD…A-L F39-JD…A-D (Gray) Communication line (+) *1 K1 KM2 Shield KM1 0 V (Blue) Safety output 1 (Black) Auxiliary output (Yellow) Not Used (Red) 24 V (Brown) 24...

https://www.omron.co.id/data_pdf/mnu/f3sj-b____n25-01tseries(quickinstallationmanual)_inst-3125963-5b.pdf

PDFSafety Light Curtain F3SJ-B□□□□P25-01TS Series

...uto reset mode, external test used F39-JDA-L F39-JDA-D (Gray) Communication line (+) KM2 Shield KM1 0 V (Blue) 24 V (Brown) Auxiliary output (Yellow) K1 Safety output 1 (Black) *1 Safety outp...

https://www.omron.co.id/data_pdf/mnu/f3sj-b____p25-01tsseries(quickinstallationmanual)_inst-3126800-6a.pdf

PDFSafety Light Curtain F3SJ-B□□□□P25-02TS Series

...g function not used, PNP output F39-JDA-L F39-JDA-D (Gray) Communication line (+) *1 KM2 Shield KM1 0 V (Blue) Safety output 1 (Black) K1 Safety output 2 (White) Auxiliary output (Yellow) 24 ...

https://www.omron.co.id/data_pdf/mnu/f3sj-b____p25-02tsseries(quickinstallationmanual)_inst-3127292-5a.pdf

PDF1 各部の名称 5 接続例 ●G9SA-321-T□ リミットスイッチ2ch入力/マニュアルリセット

...い。 (通電前にコネクタ部のロックがされていることを確認してください。 ) S1 K3、K4 b接点 K3、K4 a接点 S1 KM1、KM2 a接点 11 KM1、KM2 b接点 KM1、KM2 a接点 12 フィードバックル...

https://www.omron.co.id/data_pdf/mnu/g9sa-301_-501_-321-t__-th301(ac100-240v)_inst-0622124-0k.pdf

PDF1 各部の名称 5 接続例 ●G9SA-321-T□ リミットスイッチ2ch入力/マニュアルリセット

...T23 T22 モータコントローラ 3 4 K3 a K1 13 23 33 43 53 61 T32 1 K4 K2 K1 KM2 T23 T22 T31 SA KM1 JP 1 2 3 4 5 6 KM1 KM2 14 24 34 44 54 62 B 5 35±0.3 A1 A2 T11 4 定格・性能 T12 a K2 K1 ...

https://www.omron.co.id/data_pdf/mnu/g9sa-301_-501_-321-t__-th301(ac_dc24v)_inst-0622108-9l.pdf

PDF(7)配線について   1.配線用電線サイズは下記のものをご使用ください。

...K1 K2 13 23 34 42 11 21 K1 12 22 A1 A2 T11 + 電源入力端子 K2 KM2 a 14 24 (34) (42) K1、 K2 b接点 KM1 K1、 K2 a接点 KM2 KM1、 KM2 b接点 M * * 注.形G9SB-200-B/301-B(オートリセット...

https://www.omron.co.id/data_pdf/mnu/g9sb-200_-__g9sb-301_-__g9sb-3010_inst-0631549-0j.pdf

結果 841 - 8601344

国/地域選択

Related Contents