...or relay unit Wiring When External Device Monitoring Function Is Not Used p.18 OUT PLC IN S1 S2 KM1 KM2 KM1 KM2 E1 +24VDC 0V M KM2 KM1 KM3 Emitter Receiver Communication lin...
https://www.omron.com.tw/data_pdf/mnu/schg-720r_eng_f3sj-a.pdf
...or relay unit Wiring When External Device Monitoring Function Is Not Used p.18 OUT PLC IN S1 S2 KM1 KM2 KM1 KM2 E1 +24VDC 0V M KM2 KM1 KM3 Emitter Receiver Communication lin...
https://www.omron.com.tw/data_pdf/mnu/schg-722n_eng_f3sj-a.pdf
...V (Blue) Power supply +24 VDC (Gray) Communication line (+) (Pink) Communication line (-) S1 *1 KM1 KM2 S1 : External test/lockout reset switch (connect to 0 V if a switch is not require...
https://www.omron.com.tw/data_pdf/mnu/schg-732k_eng_f3sj-e____p25_b____p25.pdf
... 0 V (Blue) Power supply +24 VDC (Gray) Communication line (+) (Pink) Communication line (-) S1 KM1 KM2 S1 : External test/lockout reset switch (connect to 24 V if a switch is not requir...
https://www.omron.com.tw/data_pdf/mnu/schg-733j_eng_f3sj-e____n25_b____n25.pdf
... Safety output 2 (White) Shield Open Open Open Power supply +24 VDC F39-JD A-L F39-JD A-D S1 S2 KM1, KM2 K1 *1. Use a switch for small loads (input specifications: 24 V, 1.0 mA max.). *2. F3S...
https://www.omron.com.tw/data_pdf/mnu/schg-734j_eng_f3sj-b____p25-01ts.pdf
...V (Blue) Auxiliary output (Yellow) Safety output 1 (Black) Safety output 2 (White) Shield S1 S2 KM1, KM2 K1 : External test switch (connect to 24 V if a switch is not required) : Lockout rese...
https://www.omron.com.tw/data_pdf/mnu/schg-735j_eng_f3sj-b____n25-01t.pdf
... Safety output 2 (White) Shield Open Open Open Power supply +24 VDC F39-JD A-L F39-JD A-D S1 S2 KM1, KM2 K1 : External test switch (connect to 0 V if a switch is not required) : Lockout reset...
https://www.omron.com.tw/data_pdf/mnu/schg-736j_eng_f3sj-b____p25-02ts.pdf
...xample of Safety Circuit Fig. 5-3 Basic Connection with Single OS32C unit KM1KM2 S2 S3 S2 S1 M1 KM1 KM2 0V E1 0VDC (Brown) Standby input (Violet)Zone Select 1 (Orange/White)Zone Select 2 (Ora...
...fety device Stop category Reset Equivalent to 4/PLe Emergency stop pushbutton 0 Manual Wiring M KM1 KM2 KM1 KM1 KM2 KM2 S1 S2 IN0 IN1 IN2 IN3 IN4 IN5 IN6 IN7 T0 T1 T2 T3 T4 ...
...-PGA-C 3 F3SG-SRB 3 F3SG-PGA-L 3 PNP/NPN Voltage PNP Vs-3 V to Vs NPN 0 V to 3 V +24 VDC 0V PNP KM1, KM2: External device KM1 KM2 0V +24 VDC NPN KM1 KM2 24V/0V (Brown) RESET...
https://www.omron.com.tw/data_pdf/mnu/z405-e1-08_f3sg-sr_pg.pdf
...k release enable signal S5 S4 Feedback loop Emergency Stop Switch Guard lock Safety-door Switch KM1 KM2 S1 S2 KM1 +24V Open Condition monitoring of Safety-door Switch Guard M1 G9SX-B...
https://www.omron.com.vn/data_pdf/cat/a22tk_a189-e1_9_6_csm2088.pdf
...abling Grip Switch. 8 A4EG Feedback loop Lock release enable signal S5 Emergency Stop Switch S4 KM1 KM2 S1 Guard lock Safety-door Switch S2 KM1 +24V Open KM2 A1 T11 T12 T21 T22 T31 T...
https://www.omron.com.vn/data_pdf/cat/a4eg_ds_e_9_1_csm000001266.pdf
...sed while the guard is closed and the emergency stop switch S1 is released. Feedback Loop Guard KM1 S1 Non-contact Safety Door Switch Emergency Stop Switch Actuator S2 KM2 A1 T11 T12 T21 T22 ...
https://www.omron.com.vn/data_pdf/cat/d40a-2_f133-e1_2_2_csm1129085.pdf
... reset mode is selected when terminal T33 is shorted to 24 V. Auto reset mode Manual reset mode KM1 KM2 +24 V T31 T32 Reset switch KM1 Refer to the following illustration for details...
https://www.omron.com.vn/data_pdf/cat/d40a_g9sx-ns_c140-e1_10_7_csm1815.pdf
...hite S3 D2 D3 Blue S1 Non-contact Door Switch Emergency Stop Switch S2 Brown KM2 Guard Actuator KM1 D4 G9SX-NSA222-T03-@ 24 VDC S14 S24 KM1 KM2 S44 S54 L1 X1 NC T41 T42 AND Control c...
https://www.omron.com.vn/data_pdf/cat/d40z_c145-e1_8_4_csm2647.pdf
...ed, the power supply to the motor M is permitted. Lock release enable signal S4 S1: S2: S3: S4: KM1 and KM2: M: S2 E1 E2 41 51 42 52 11 21 31 12 22 32 61 Safety Limit Switch with direct openi...
https://www.omron.com.vn/data_pdf/cat/d4jl_d4jl-sk40_ds_e_10_7_csm1239.pdf
...ct opening mechanism S2: Guard Lock Safety-door Switch S3: Reset switch S4: Lock release switch KM1 and KM2: Magnetic contactor M: Motor 54 41 53 12 32 11 31 Condition monitoring of Safety-do...
https://www.omron.com.vn/data_pdf/cat/d4nl_ds_e_9_9_csm1240.pdf
...chanism S2: Guard Lock Safety-door Switch D4SL-N@E@A-@ S3: Reset switch S4: Lock release switch KM1 and KM2: Magnetic contactor M: Motor S2 10 42 64 41 1 63 12 22 34 11 21 33 2 3 4 5 6 7 8 Co...
https://www.omron.com.vn/data_pdf/cat/d4sl-n_c146-e1_8_8_csm1004285.pdf
...RANGE SELECT INPUT (Yellow) *2 Not used (White) 0V/24V (Blue) Emitter Receiver [Wiring Example] KM1 KM2 M S2 KM1 S1 Needed KM1 KM2 Wiring for NPN *1 KM2 24 VDC 24 VDC *3 : ...
https://www.omron.com.vn/data_pdf/cat/f3sg-sr_pg_f117-e1_1_9_csm1120108.pdf
...tor M is kept OFF until the beams are unblocked and the reset switch S2 is pressed. +24 V +24 V KM1 +24 V Feedback loop KM2 (Gray) Communication line (+) K1 K1 K2 K2 K3 K3 K1 K3 K2 K3 ...