PDF1 Overview 2 Procedures Power Line Data Generator ...

... frequency 45 to 245 Hz Since wave Current Absolute accuracy: 0.5%FS±1digit Repeat accuracy: ±1%rdg±1digit • Not including accuracy variation of CTs • The power frequency must be within the r...

https://www.omron.com.au/data_pdf/mnu/n233-e1-04_k7dd.pdf

PDFDigital Multicircuit Protector S8M

...°C, Over-temperature Output Display functions Display range:17.0 to 30.0 V Display accuracy: 2% rdg ±1 digit max. Input voltage display/ detection Setting range: 0.5 to 3.8 A (in 0.1-A units)...

https://www.omron.com.au/data_pdf/mnu/z241-e1-03_s8m.pdf

PDFSmart Power Supply S8AS USER'S MANUAL

...ent: 0.1 mA max., Residual voltage: 2 V max. Display range: 17.0 to 30.0 V Display accuracy: 2% rdg ±1 digit max. Branch output display range: 0.0 to 4.0 A Peak output current display range: ...

https://www.omron.com.au/data_pdf/mnu/z269-e1-07_s8as.pdf

PDFCSM_D5V_DS_TW_1_8 1 接觸式變位感測器D5V

...閱本公司網站(http://www.omron.com.tw)。 和數位控制電錶的連接範例產品名稱電壓/電流控制電錶型號K3HB-XAD-@@@ 特點 ˙準確度±0.1%rdg±1位數以下 ˙備有接點、電晶體、BCD、通訊、線性等各種輸出模組 ˙...

https://www.omron.com.tw/data_pdf/cat/d5v_ds_tw_1_8.pdf

PDF1 Infrared Thermosensor ES1-N Measure Workpieces w...

...(24 VDC, Using laser pointer) Cable length 2 m±5 cm Measurement accuracy USB output •Within±(-8%rdg+1)°C (Measurement temperature: -50 to 0°C) •Within±1°C (0 to 200°C) •Within±0.5%...

https://www.omron.com.tw/data_pdf/cat/es1-n_h227-e1_4_4_csm1059198.pdf

PDFCSM_K3HB-R_DS_TW_16_2 1 旋轉脈衝電錶K3HB-R

...5SC(01)、 壓接端子(廣瀨電機:HR31-SC-121))。 *3 5 K3HB-R ■性能可顯示範圍-19999~99999 測量精度(at23±5℃) 功能F1、F6:±0.006%rdg±1數值(感測器為電壓脈衝/開路集極型時) 功能F2~F5:±0...

https://www.omron.com.tw/data_pdf/cat/k3hb-r_ds_tw_16_2.pdf

PDFCSM_K3HB-V_DS_E_11_6 1 Weighing Indicator K3HB-V

...ambient temperature of 23±5°C. For all ranges,10% or less of max. input±0.1% FS. 2. The letters“rdg”mean“reading.” The area shown in dark shading indicates the factory setting. „Load Cell Wir...

https://www.omron.com.tw/data_pdf/cat/k3hb-v_ds_e_11_6_csm264.pdf

PDFCSM_K3HB-V_DS_TW_11_3 1 荷重計、mV電錶K3HB-V

...(測量範圍與精度) 註1.環境溫度23±5℃下保證測量精度。 但輸入範圍在輸入最大值的10%以下時,誤差為±0.1%FS。 2.字母rdg為讀數值。 為購買本產品時的設定狀態。 ■荷重計配線例 ■scaling範例 (使用外部...

https://www.omron.com.tw/data_pdf/cat/k3hb-v_ds_tw_11_3.pdf

PDFCSM_K3HB-X_DS_E_12_6 1 Process Indicator K3HB-X

... resistance of approximately 1 MΩbetween the input ter- minals if they are open. 2. The letters“rdg”mean“reading”and refer to the input error. 3. The value (0.5 VA CT) is the VA consumption o...

https://www.omron.com.tw/data_pdf/cat/k3hb-x_ds_e_12_6_csm254.pdf

PDFCSM_K3HB-X_DS_TW_12_3 1 電壓/電流控制電錶K3HB-X

...免輸入端子間成為開路。 開路會導致顯示產生大幅偏差。 如為開路狀態,請在輸入端子間連接1MΩ左右的電阻。 2.字母rdg為讀數值,表示相對於輸入的誤差。 *1.K3HB-XVA@@型適用UL安全規格時,輸入施加電壓為A...

https://www.omron.com.tw/data_pdf/cat/k3hb-x_ds_tw_12_3.pdf

PDF1 Motor Condition Monitoring Device

...Ω, Leakage current: 0.0 mA to 200.0 mA Measurement absolute accuracy Insulation resistance ±35% rdg±2 digit (when the insulation resistance is 0.2 MΩmax.), when a 200-V/7.5-kW max. motor is u...

https://www.omron.com.tw/data_pdf/cat/k6cm_n218-e1_3_1_csm1060693.pdf

PDF馬達狀態監控機器 K6CM系列 ●追加推出亦適用於使用變頻器環境的機種。

...5.在EIP CPU版本1.2以上時才能使用。 測量範圍絕緣阻抗:0.000M~1.000MΩ, 漏電電流:0.0mA~200.0mA 測量絕對精度絕緣阻抗 ±35%rdg±2digit(絕緣阻抗0.2MΩ以下時),使用200V/7.5kW以下的馬達時*1 ±35...

https://www.omron.com.tw/data_pdf/cat/k6cm_sgte-660_tw_3_5.pdf

PDF1 Advanced Motor Condition Monitoring Device K7DD

...y (Ambient temperature: 10 to 30°C) Current Absolute accuracy: 0.5%FS±1digit Repeat accuracy:±1%rdg±1digit Not including accuracy variation of CTs The power frequency must be within the rated...

https://www.omron.com.tw/data_pdf/cat/k7dd_n234-e1_3_3_csm1124083.pdf

PDF進階型馬達狀態監測器 K7DD 捕捉馬達設備之多種異常徵兆, 將設備停止損失最小化

...0.0V 600V範圍:300.0 ~ 600.0V 驅動頻率45 ~ 245Hz在正弦波量測精度 (環境溫度10 ~ 30°C) 電流絕對精度:±0.5%FS±1digit 反復精度:±1%rdg±1digit •不包含CT精度之偏差 •驅動頻率在額定範圍內電壓絕對精度...

https://www.omron.com.tw/data_pdf/cat/k7dd_sgte-667b-tw5_2_1.pdf

PDF1 Insulation Resistance Monitoring Device K7GE-MG

...ecifications Measurement range 0.1 to 99.9 MΩ(0.0 MΩfor less than 0.1 MΩ) Measuring accuracy±5% rdg.±1 digit (at ambient temperature -10 to 55°C and ambient humidity 25% to 65%) Megger voltag...

https://www.omron.com.tw/data_pdf/cat/k7ge-mg_n225-e1_2_2_csm1106906.pdf

PDF自動測量絕緣電阻 主動掌握劣化趨勢以防突然停機 絕緣阻抗監視機器

...晶體輸出端子的輸出規格電壓輸入端子的輸入規格規格項目規格測量範圍0.1~99.9MΩ(未達0.1MΩ時為0.0MΩ) 測量精度±5%rdg±1digit(環境溫度-10~55℃、環境濕度25~65%RH) 高阻計電壓DC50V 測量動作每個觸...

https://www.omron.com.tw/data_pdf/cat/k7ge_sgte-662_tw_1_3.pdf

PDF1 Heater Condition Monitoring Device K7TM

... •Variations in CTs are not included. Repeat accuracy of resistance value (reference value):±1% rdg±1 digit Conditions: •When sine waves are input continuously •Variations in CTs are not incl...

https://www.omron.com.tw/data_pdf/cat/k7tm_n228-e1_3_3_csm1115712.pdf

PDF1 智慧型電源供應器(240/480W型) S8AS 注重安全性與維護性的新電源型態

...出光開關輸出 DC30V Max. 50mA Max.、漏電流0.1mA以下、殘留電壓2V以下顯示功能輸出電壓顯示顯示範圍:17.0~30.0V 顯示精度:2%rdg±1位數以下輸出電流顯示分支輸出電流顯示範圍:0.0~4.0A 分支輸出峰值...

https://www.omron.com.tw/data_pdf/cat/s8as_sgtc-030_tw_8_3.pdf

PDF1 Smart Power Supply S8AS A New Type of Power Supp...

...max. Display functions Output voltage display Display range:17.0 to 30.0 V Display accuracy: 2% rdg±1 digit max. Output current display Branch output display range: 0.0 to 4.0 A Peak output c...

https://www.omron.com.tw/data_pdf/cat/s8as_t228-e1_9_6_csm1381.pdf

PDF1 多重數位電路保護器 S8M 業界首創DC電路保護器, 配備顯示及警報輸出等

...開路集極輸出 DC30V max. 50mA max.、漏電流0.1mA以下、殘留電壓2V以下顯示功能輸入電壓顯示顯示範圍:17.0~30.0V 顯示精度:2%rdg±1位數以下輸出電流顯示分支輸出顯示範圍:0.0~4.0A 峰值電流顯示範圍...

https://www.omron.com.tw/data_pdf/cat/s8m_sgtc-023_tw_2_2.pdf