IAグローバル検索 |
...力(PNP対応) 定格出力電流0.5A以下/点 ON残電圧1.2V以下各出力端子とV間漏れ電流0.1mA以下項目仕様使用リレーG7SA-2A2B,IEC61810-3 Class A 故障率P水準(参考値*) DC5V 1mA 定格負荷(抵抗負荷) AC240...
https://www.omron.com.tw/data_pdf/mnu/dst1-id_m(r)d_xd__(__)sl-1_inst-1625834-7i.pdf
...tch is not required) : Interlock/lockout reset switch : Safety relay with force-guided contact (G7SA) or magnetic contactor : Load or PLC, etc. (for monitoring) K1 KM1 KM2 0 V Emitter Receive...
... switch (connect to 24 V if a switch is not required) : Safety relay with force-guided contact (G7SA) or magnetic contactor : Load or PLC, etc. (for monitoring) Shield Not Used (Red) 0 V (Blu...
... switch (connect to 24 V if a switch is not required) : Safety relay with force-guided contact (G7SA) or magnetic contactor : Load or PLC, etc. (for monitoring) Shield Not Used (Red) 0 V (Blu...
... switch (connect to 24 V if a switch is not required) : Safety relay with force-guided contact (G7SA) or magnetic contactor : Load or PLC, etc. (for monitoring) Shield Not Used (Red) 0 V (Blu...
...r releasing lockout) S2 : Zone Select Switch S3 : Standby Switch KM1, KM2: Forced guided relay (G7SA) or magnetic contactor M1 : 3-Phase Motor E1 : 24 VDC Power Zone Select 1 (Orange/White) W...
https://www.omron.com.tw/data_pdf/mnu/os32c_inst-99863-0020m.pdf
...quired) S2 :Interlock/lockout reset switch KM1, KM2 :Safety relay with forcibly-guided contact (G7SA) or magnetic contactor KM3 : Load or PLC (for monitoring) KM4 :Solid state contactor (G3J)...
https://www.omron.com.tw/data_pdf/mnu/schg-716n_eng_f3sj-am.pdf
...quired) S2 :Interlock/lockout reset switch KM1, KM2 :Safety relay with forcibly-guided contact (G7SA) or magnetic contactor KM3 : Load or PLC (for monitoring) KM4 :Solid state contactor (G3J)...
https://www.omron.com.tw/data_pdf/mnu/schg-718s_eng_f3sj-a.pdf
... switch S2 :Interlock/lockout reset switch KM1, KM2 :Safety relay with forcibly-guided contact (G7SA) or magnetic contactor KM3 : Load or PLC (for monitoring) KM4 :Solid state contactor (G3J)...
https://www.omron.com.tw/data_pdf/mnu/schg-719s_eng_f3sj-a.pdf
...cuit to 24V if the switch is not required) KM1, KM2 :Safety relay with forcibly-guided contact (G7SA) or magnetic contactor KM3 :Solid state contactor (G3J) M :Motor E1 :24VDC power supply (S...
https://www.omron.com.tw/data_pdf/mnu/schg-720r_eng_f3sj-a.pdf
...onnect to 24V if a switch is not required) KM1, KM2 :Safety relay with forcibly-guided contact (G7SA) or magnetic contactor KM3 :Solid state contactor (G3J) M :Motor E1 :24VDC power supply (S...
https://www.omron.com.tw/data_pdf/mnu/schg-722n_eng_f3sj-a.pdf
...(connect to 0 V if a switch is not required) KM1, KM2 : Safety relay with force-guided contact (G7SA) or magnetic contactor *1. Use a switch for small loads (input specifications: 24 V, 1.0 m...
https://www.omron.com.tw/data_pdf/mnu/schg-732k_eng_f3sj-e____p25_b____p25.pdf
...connect to 24 V if a switch is not required) KM1, KM2 : Safety relay with force-guided contact (G7SA) or magnetic contactor *1 *1. Use a switch for small loads (input specifications: 24 V, 3 ...
https://www.omron.com.tw/data_pdf/mnu/schg-733j_eng_f3sj-e____n25_b____n25.pdf
... switch (connect to 24 V if a switch is not required) : Safety relay with force-guided contact (G7SA) or magnetic contactor : Load or PLC, etc. (for monitoring) 24 V (Brown) External device m...
https://www.omron.com.tw/data_pdf/mnu/schg-734j_eng_f3sj-b____p25-01ts.pdf
... switch (connect to 24 V if a switch is not required) : Safety relay with force-guided contact (G7SA) or magnetic contactor : Load or PLC, etc. (for monitoring) Shield Not Used (Red) 0 V (Blu...
https://www.omron.com.tw/data_pdf/mnu/schg-735j_eng_f3sj-b____n25-01t.pdf
... switch (connect to 24 V if a switch is not required) : Safety relay with force-guided contact (G7SA) or magnetic contactor : Load or PLC, etc. (for monitoring) 24 V (Brown) External device m...
https://www.omron.com.tw/data_pdf/mnu/schg-736j_eng_f3sj-b____p25-02ts.pdf
...r releasing lockout) S2 : Zone Select Switch S3 : Standby Switch KM1, KM2: Forced guided relay (G7SA) or magnetic contactor M1 : 3-Phase Motor E1 : 24 VDC Power Functional Earth (Green) 24VDC...
...case, it may make a hole. Caution This problem may even occur with the PWB-mounted type G7J and G7SA. Solution 34 Case Swelling This phenomenon causes the top and sides of the case of a relay...
https://www.omron.com.tw/data_pdf/mnu/z384-e1-04_relay_tg.pdf
...KM2 S1 KM1 KM2 M S1: Lockout reset switch KM1, KM2: Safety relay with forcibly guided contacts (G7SA) or magnetic contactor M: Motor Receiver Emitter OSSD 1 (Black) OSSD 2 (White) 24V/0V (Bro...
https://www.omron.com.tw/data_pdf/mnu/z405-e1-07_f3sg-sr_pg.pdf
...網路商店 Home 網路商店 安全元件 安全繼電器 / G7SA G7SA-3A1B DC24 購物車 (0) 安全繼電器 G7SA-3A1B DC24 小型薄型安全繼電器 商品資訊 付款方式: 貨到付現、貨到刷卡、匯款 交貨方...