IAグローバル検索 |
...connect to 24 V if a switch is not required) KM1, KM2 : Safety relay with force-guided contact (G7SA) or magnetic contactor *1. Use a switch for small loads (input specifications: 24 V, 3 mA)...
https://www.omron.com.au/data_pdf/mnu/schg-733j_eng_f3sj-e____n25_b____n25.pdf
...connect to 24 V if a switch is not required) KM1, KM2 : Safety relay with force-guided contact (G7SA) or magnetic contactor K1 : Load or PLC, etc. (for monitoring) *1. Use a switch for small ...
https://www.omron.com.au/data_pdf/mnu/schg-734j_eng_f3sj-b____p25-01ts.pdf
... switch (connect to 24 V if a switch is not required) : Safety relay with force-guided contact (G7SA) or magnetic contactor : Load or PLC, etc. (for monitoring) *1. Use a switch for small loa...
https://www.omron.com.au/data_pdf/mnu/schg-735j_eng_f3sj-b____n25-01t.pdf
...connect to 24 V if a switch is not required) KM1, KM2 : Safety relay with force-guided contact (G7SA) or magnetic contactor K1 : Load or PLC, etc. (for monitoring) *1. Use a switch for small ...
https://www.omron.com.au/data_pdf/mnu/schg-736j_eng_f3sj-b____p25-02ts.pdf
...r releasing lockout) S2 : Zone Select Switch S3 : Standby Switch KM1, KM2: Forced guided relay (G7SA) or magnetic contactor M1 : 3-Phase Motor E1 : 24 VDC Power *1. If the External Device Mon...
...e to 0 V if this switch is not required.) KM1, KM2: Safety relay with forcibly guided contacts (G7SA) or magnetic contactor E1: 24VDC power supply (S8VS) PLC: Programmable controller (Used fo...
https://www.omron.com.au/data_pdf/mnu/z380-e1-04_f3sg-4ra____-25-01ts.pdf
...l Earth Beam state Unblocked Blocked OSSD KM1, KM2: Safety relay with forcibly guided contacts (G7SA) M: Motor *1. Connect the line to 24 V via a test switch (N.O. contact) if External Test i...
https://www.omron.com.au/data_pdf/mnu/z391-e1-03_f3sg-4ar____-25-02ts.pdf
...uting] : Disable S1: Lockout reset switch KM1, KM2: Safety relay with forcibly guided contacts (G7SA) or magnetic contactor M: Motor *1. Reverse the polarity of the power supply when using in...
https://www.omron.com.au/data_pdf/mnu/z405-e1-07_f3sg-sr_pg.pdf
...the laser power ON/OFF based on the 15 Safety relay signal from the interlock connector. Model: G7SA-2A2B DC24 *1 Do not use the USB interface for anything other than specified. Fiber Laser M...
https://www.omron.com.au/data_pdf/mnu/z415-e1-08_mx-z2000h-v1.pdf
... 0.7 A max./output ON residual voltage 1.2 V max. Leakage current 0.1 mA max. Applicable relays G7SA-2A2B, EN50205 Class A Failure rate P level * (Reference value) 5 VDC, 1 mA Rated load (res...
https://www.omron.com.tw/data_pdf/cat/dst1_series_ds_e_7_4_csm1275.pdf
...switch S2: Lockout/interlock reset switch KM1, KM2: Safety relay with forcibly guided contacts (G7SA) or magnetic contactor M: Motor Beam state: Unblocked Blocked Test switch (S1) Reset switc...
https://www.omron.com.tw/data_pdf/cat/f3sg-sr_pg_f117-e1_1_8_csm1120108.pdf
...e Emitter and Receiver. Test rod (Sold separately) Type Appearance Specifications Model Remarks G7SA Relays with Forcibly Guided Contacts •Nodes: 4 •Contact type: 2A2B •Rated switch load: 250...
https://www.omron.com.tw/data_pdf/cat/f3sj_f074-e1_27_11_csm1816.pdf
...位數字。 *2.若要同時使用投光器與受光器,請購買一套2組的F39-PB@@@@型保護桿。 測試棒(另售) 種類外觀規格型號備註 G7SA型安全繼電器・極數:4極・接點構成:2A2B ・額定開關負載: AC250V 6A、DC30V 6A...
https://www.omron.com.tw/data_pdf/cat/f3sj_schg-015_tw_26_8.pdf
... of enclosed construction. Therefore, do not wash the G7S with water or detergent. Mounting The G7SA can be installed in any direction. Indicates a potentially hazardous situation which, if n...
https://www.omron.com.tw/data_pdf/cat/g7s-_-e_ds_e_7_3_csm1272.pdf
...1 Relays with Forcibly Guided Contacts G7SA Compact, Slim Relays Conforming to EN Standards •Additional Push-In Plus terminal sockets are used to save wiring work in comparison with tradition...
https://www.omron.com.tw/data_pdf/cat/g7sa_j120-e1_12_12_csm1269.pdf
...1 新商品資訊安全繼電器 G7SA 已取得EN標準的小型薄型安全繼電器 •產品系列新增Push-In Plus端子台底座,與傳統的螺絲鎖合型端子相較下,配線所需工時更短 (配線所需工時較傳統的螺絲鎖合型端子縮短約60%*...
https://www.omron.com.tw/data_pdf/cat/g7sa_sgfr-207_tw_12_4.pdf
...應電源。 最大可能達到PL/ 安全類別使用機器型號停止類別復歸方法相當於PLd/3 安全雷射掃描器OS32C 安全繼電器G7SA 0手動操作 OS32C型的設定・外部繼電器監控功能開啟・啟動/重新啟動連鎖 DC24V(白) DC0V...
https://www.omron.com.tw/data_pdf/cat/os32c_schg-030_tw_14_4.pdf
...egory Model Stop category Reset PLd/3 equivalent Safety Laser Scanner OS32C Forced Guided Relay G7SA 0Manual OS32C Configuration - External Device Monitoring Enabled - Start/Restart Interlock...
https://www.omron.com.tw/data_pdf/cat/os32c_z298-e1_14_6_csm2602.pdf
...K8DT 按鈕開關 A22N-P/A30N-P/M22N-P 緊急停止用按鈕開關 A22NE-P 賦予控制盤全新價值的商品系列安全繼電器插座 (G7SA用) P7SA-PU� 溫度控制器 (數位溫度控制器) E5CC-B/E5EC-B 溫度控制器 (數位溫度...
https://www.omron.com.tw/data_pdf/cat/s8vk-s_sgtc-063_tw_1_8.pdf
...計測監視保護繼電器 K8DT 鋁軌端子台 XW5T 按鈕開關 Push-In Plus 端子台系列 A22N-P/A30N-P/M22N-P 安全繼電器底座 (G7SA專用) P7SA-PU 溫度控制器 (數位溫控器) E5CC-B/E5EC-B 電量監控器 KM-N2/KM-N3 控...
https://www.omron.com.tw/data_pdf/cat/xw5t_sdca-002_tw_1_3.pdf