Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 1711 - 1720 of 16959
E52-THE5A / 6D / 6F Temperature Sensor (Thermistor...
...changeable thermistor Class JIS class 1 Protective tubing material SUS304 Time constant 8 to 15 s in still water Dissipation factor 2.4 to 2.8 mW/°C in still air Lead wire heat resistive temp...

https://www.ia.omron.com/products/family/1743/specification.html

S8M Digital Multicircuit Protector/Specifications ...
...put Startup sequence Can be enabled/disabled for each branch output, setting range: 0.0 to 99.9 s in 0.1-s units. Shutdown sequence Can be enabled/disabled for each branch output, se...

https://www.ia.omron.com/products/family/1768/specification.html

K7L-U[] / UD[][] Liquid Leakage Sensor Amplifiers ...
...1 W max. Response time Operate: 800 ms max. Release: 800 ms max. Startup time after power ON: 2 s max. Weight Approx. 14 g Ratings Rated power supply voltage 12 to 24 VDC (Allowable voltage f...

https://www.ia.omron.com/products/family/1819/specification.html

CRS1-RPT01 Repeater Unit/Specifications | OMRON In...
...-4 2 kV (power line). Vibration resistance 10 to 150 Hz with double-amplitude of 0.7 mm or 50 m/s 2 Shock resistance 150 m/s 2 Dielectric strength 500 VAC (between isolated circuits)...

https://www.ia.omron.com/products/family/1826/specification.html

XS5 Round Water-resistant Connectors (M12 Smartcli...
...ns Catalog last update: March 3, 2022 Ratings and Specifications Item XS5-F, XS5C/G, XS5P/M XS5-S/PR XS5-P/SA Rated current 4 A 3 A 3 A Rated voltage 250 VDC 250 VDC 125 VDC Contact resistanc...

https://www.ia.omron.com/products/family/1827/specification.html

SC Limit Switch Connectors/Dimensions | OMRON Indu...
...g G½ SC-21 to 25 Metal Models with O-ring G½ SC-1M to 5M Metal Models without O-ring ½-14NPT (U.S.-standard screws) SC-1PT to 5PT Note: Dimensions not shown in the above diagrams have a varia...

https://www.ia.omron.com/products/family/1867/dimension.html

P7TF-IS16 / OS16 / OS08 I/O Terminal Socket/Dimens...
... for short-circuiting across terminals. Max. current flow: 20 A Output Short-Circuit Module G77-S The output of the I/O Relay Terminal can be obtained without relays through the G77-...

https://www.ia.omron.com/products/family/1902/dimension.html

P7TF-IS16 / OS16 / OS08 I/O Terminal Socket/Specif...
...at 500 VDC) Vibration resistance 10 to 55 Hz with 1.0-mm double amplitude Shock resistance 200m/s 2 Noise immunity Noise level: 1.6 kV; pulse width: 100 ns to 1 μs Ambient operating temperatu...

https://www.ia.omron.com/products/family/1902/specification.html

XW3D Connector Terminal Boxes/Lineup | OMRON Indus...
... 0.39 and 0.49 N·m to tighten the Water-resistive Cover. XS5Z-11 is Smartclick mechanism. There's no need to keep track of locking torque. XS2Z-22 Brass with Ni plating Note 1. The XW3D comes...

https://www.ia.omron.com/products/family/1913/lineup.html

XW3D Connector Terminal Boxes/Specifications | OMR...
...of protection IP67 (IEC60529) Insertion tolerance 50 times min. Lock strength Pulling: 100 N/15 s, Twisting: 1 N·m/15 s Cable holding strength 100 N/15 s Lock operating forc...

https://www.ia.omron.com/products/family/1913/specification.html

Results 1711 - 1720 of 16959