Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 1711 - 1720 of 16993
CJ1W-IDP01 CJ-series Quick-response Input Units/Sp...
...se "Jxx" as the device name. With quick-response inputs, pulse inputs shorter than the CPU Unit's cycle time can be read by the CPU Unit. The pulse width (ON time) that can be read by the Qui...

https://www.ia.omron.com/products/family/1643/specification.html

CJ1W-PTS CJ-series Process Analog I/O Unit/Lineup ...
...uple Input Units) 2 inputs Set sepa- rately for each input Thermo- couple: B, E, J, K, L, N, R, S, T, U, WRe5- 26, PLII DC voltage: ± 100 mV Conver- sion speed: 10 ms/ 2 inputs, Resolu- tion:...

https://www.ia.omron.com/products/family/1644/lineup.html

CJ1W-PDC15 CJ-series Process Analog I/O Unit/Lineu...
...A, 4 to 20 mA Conver- sion speed: 10 ms/ 2 inputs Resolu- tion: 1/64,000 Accuracy: ± 0.05% of F.S. Re- movable terminal block 1 0.18 0.09 * CJ1W-PDC15 UC1, CE * This is for an external power ...

https://www.ia.omron.com/products/family/1646/lineup.html

CS1W-PTS SYSMAC CS-series Process Analog I/O Units...
...ed- type Thermo- couple Input Units 4 inputs Set separately for each input B, E, J, K, L, N, R, S, T, U, WRe5-26, PLII, ± 100 mV 20 ms/ 4 inputs, 10 ms/ 2 inputs Removable terminal block 1 0....

https://www.ia.omron.com/products/family/1664/lineup.html

CS1W-FLN22 CS-series FL-net Unit/Specifications | ...
...stance Conforms to JIS 0040. 10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz, acceleration: 9.8 m/s 2 in X, Y, and Z directions for 80 minutes each (Time coefficient; 8 minutes × coefficient fa...

https://www.ia.omron.com/products/family/1683/specification.html

E52-THE5A / 6D / 6F Temperature Sensor (Thermistor...
...changeable thermistor Class JIS class 1 Protective tubing material SUS304 Time constant 8 to 15 s in still water Dissipation factor 2.4 to 2.8 mW/°C in still air Lead wire heat resistive temp...

https://www.ia.omron.com/products/family/1743/specification.html

S8M Digital Multicircuit Protector/Specifications ...
...put Startup sequence Can be enabled/disabled for each branch output, setting range: 0.0 to 99.9 s in 0.1-s units. Shutdown sequence Can be enabled/disabled for each branch output, se...

https://www.ia.omron.com/products/family/1768/specification.html

K7L-U[] / UD[][] Liquid Leakage Sensor Amplifiers ...
...1 W max. Response time Operate: 800 ms max. Release: 800 ms max. Startup time after power ON: 2 s max. Weight Approx. 14 g Ratings Rated power supply voltage 12 to 24 VDC (Allowable voltage f...

https://www.ia.omron.com/products/family/1819/specification.html

CRS1-RPT01 Repeater Unit/Specifications | OMRON In...
...-4 2 kV (power line). Vibration resistance 10 to 150 Hz with double-amplitude of 0.7 mm or 50 m/s 2 Shock resistance 150 m/s 2 Dielectric strength 500 VAC (between isolated circuits)...

https://www.ia.omron.com/products/family/1826/specification.html

XS5 Round Water-resistant Connectors (M12 Smartcli...
...ns Catalog last update: March 3, 2022 Ratings and Specifications Item XS5-F, XS5C/G, XS5P/M XS5-S/PR XS5-P/SA Rated current 4 A 3 A 3 A Rated voltage 250 VDC 250 VDC 125 VDC Contact resistanc...

https://www.ia.omron.com/products/family/1827/specification.html

Results 1711 - 1720 of 16993