Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 1771 - 1780 of 16971
NX-TS NX-series Temperature Input Unit/Lineup | OM...
... points 16 Ter- minals x 2 NX-TS3204 *1. The resolution is 0.2°C max. when the input type is R, S, or W. *2. The NX-TS2202 and NX-TS3202 only support Pt100 three-wire sensor. Optional Product...

https://www.ia.omron.com/products/family/3189/lineup.html

NX-EC0[][][] NX-series Incremental Encoder Input U...
...4-V voltage input NX-EC0212 2 (PNP) NX-EC0222 * Refer to the I/O Refreshing Methods in the USER'S MANUAL (Cat. No. W524) for the communications cycles for each   model. Optional Products Prod...

https://www.ia.omron.com/products/family/3190/lineup.html

A3U Plateau Head Pushbutton Switch/Specifications ...
... to 55 Hz, 1.5-mm double amplitude (malfunction within 1 ms) Shock resistance Malfunction 300 m/s 2 max. (malfunction within 1 ms) Durability Mechanical 1,000,000 operations min. Electrical 2...

https://www.ia.omron.com/products/family/3194/specification.html

A3US Plateau Head Knob-type Selector Switch/Specif...
... to 55 Hz, 1.5-mm double amplitude (malfunction within 1 ms) Shock resistance Malfunction 300 m/s 2 max. (malfunction within 1 ms) Durability Mechanical 250,000 operations min. Electrical 100...

https://www.ia.omron.com/products/family/3195/specification.html

V680S Series RFID System/Dimensions | OMRON Indust...
...80-A80 V680-D1KP54T Attachment V700-A80 Connector Cover V680S-A63 V680S-A64 V680S-A66 V680S-A63-S V680S-A64-S Cable for Modbus TCP V680S-A41 []M/V680S-A51 []M * Special connector ---...

https://www.ia.omron.com/products/family/3198/dimension.html

EE-SX95 Ultra-compact Pre-wired Photomicrosensor (...
...ing or condensation) Vibration resistance (destruction) 10 to 2,000 Hz (peak acceleration: 150m/s 2 ) with a 0.75-mm single amplitude for 2.5 h (15-min periods, 10 cycles) each in X, Y, and Z...

https://www.ia.omron.com/products/family/3199/specification.html

S8VK-R Redundancy Unit/Specifications | OMRON Indu...
...to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z directions Shock resistance 150 m/s 2 , 3 times each in ±X, ±Y, and ±Z directions EMI Conducted Emission Conforms to EN 61000-6-3...

https://www.ia.omron.com/products/family/3237/specification.html

K8AK-LS Conductive Level Controller/Specifications...
...sistance 10 k to 100 kΩ (variable) Reset resistance 250 kΩ max. Response time Approx. 0.1 to 10 s (variable) Length of cable 100 m max. (fully insulated 3-core 0.75-mm 2 cab-tyre cable, 600 V...

https://www.ia.omron.com/products/family/3240/specification.html

NX-SI / SO Safety I/O Unit/Lineup | OMRON Industri...
...    NX-SIH400 without any dedicated controller. Refer to the NX-series Safety Control Unit User's Manual (Cat. No. Z930) for     details. Type Model and corresponding PL and safety category O...

https://www.ia.omron.com/products/family/3244/lineup.html

D4CC Miniature Limit Switch/Specifications | OMRON...
...min. Electrical 200,000 operations min. (1 A at 125 VAC, resistive load) Operating speed 0.1 mm/s to 0.5 m/s (in case of plunger) 1 mm/s to 1 m/s (in case of roller...

https://www.ia.omron.com/products/family/325/specification.html

Results 1771 - 1780 of 16971