K6CM Motor Condition Monitoring Device/Specificati...- ...Ω, Leakage current: 0.0 mA to 200.0 mA Measurement absolute accuracy Insulation resistance ±35% rdg±2 digit (when the insulation resistance is 0.2 MΩ max.), when a 200-V/7.5-kW max. motor is ...
https://www.ia.omron.com/products/family/3686/specification.html
1 Infrared Thermosensor ES1-N Measure Workpieces w...- ...(24 VDC, Using laser pointer) Cable length 2 m±5 cm Measurement accuracy USB output •Within±(-8%rdg+1)°C (Measurement temperature: -50 to 0°C) •Within±1°C (0 to 200°C) •Within±0.5%...
https://www.ia.omron.com/data_pdf/cat/es1-n_h227-e1_4_4_csm1059198.pdf
CSM_K3HB-V_DS_E_11_6 1 Weighing Indicator K3HB-V- ...ambient temperature of 23±5°C. For all ranges,10% or less of max. input±0.1% FS. 2. The letters“rdg”mean“reading.” The area shown in dark shading indicates the factory setting. Load Cell Wir...
https://www.ia.omron.com/data_pdf/cat/k3hb-v_ds_e_11_6_csm264.pdf
CSM_K3HB-X_DS_E_12_6 1 Process Indicator K3HB-X- ... resistance of approximately 1 MΩbetween the input ter- minals if they are open. 2. The letters“rdg”mean“reading”and refer to the input error. 3. The value (0.5 VA CT) is the VA consumption o...
https://www.ia.omron.com/data_pdf/cat/k3hb-x_ds_e_12_6_csm254.pdf
1 Motor Condition Monitoring Device- ...Ω, Leakage current: 0.0 mA to 200.0 mA Measurement absolute accuracy Insulation resistance ±35% rdg±2 digit (when the insulation resistance is 0.2 MΩmax.), when a 200-V/7.5-kW max. motor is u...
https://www.ia.omron.com/data_pdf/cat/k6cm_n218-e1_3_1_csm1060693.pdf
1 Motor Condition Monitoring Device K6CM-CI- ...Ω, Leakage current: 0.0 mA to 200.0 mA Measurement absolute accuracy Insulation resistance ±35% rdg±2 digit (when the insulation resistance is 0.2 MΩmax.), when a 200-V/7.5-kW max. motor is u...
https://www.ia.omron.com/data_pdf/cat/k6cm_n218-e1_5_4_csm1060693.pdf
1 Advanced Motor Condition Monitoring Device K7DD- ...y (Ambient temperature: 10 to 30°C) Current Absolute accuracy: 0.5%FS±1digit Repeat accuracy:±1%rdg±1digit Not including accuracy variation of CTs The power frequency must be within the rated...
https://www.ia.omron.com/data_pdf/cat/k7dd_n234-e1_3_3_csm1124083.pdf
1 Insulation Resistance Monitoring Device K7GE-MG- ...ecifications Measurement range 0.1 to 99.9 MΩ(0.0 MΩfor less than 0.1 MΩ) Measuring accuracy±5% rdg.±1 digit (at ambient temperature -10 to 55°C and ambient humidity 25% to 65%) Megger voltag...
https://www.ia.omron.com/data_pdf/cat/k7ge-mg_n225-e1_2_2_csm1106906.pdf
1 Heater Condition Monitoring Device K7TM- ... •Variations in CTs are not included. Repeat accuracy of resistance value (reference value):±1% rdg±1 digit Conditions: •When sine waves are input continuously •Variations in CTs are not incl...
https://www.ia.omron.com/data_pdf/cat/k7tm_n228-e1_3_3_csm1115712.pdf
1 Smart Power Supply S8AS A New Type of Power Supp...- ...max. Display functions Output voltage display Display range:17.0 to 30.0 V Display accuracy: 2% rdg±1 digit max. Output current display Branch output display range: 0.0 to 4.0 A Peak output c...
https://www.ia.omron.com/data_pdf/cat/s8as_t228-e1_9_6_csm1381.pdf