Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 241 - 250 of 261
K3HB-XVD-T12 AC100-240 | OMRON Industrial Automati...
...t Measurement range A: ±199.99 V B: ±19.999 V C: ±1.9999 V D: 1.0000 to 5.0000 V Accuracy ±0.1% rdg ±1 digit max. Input impedance A: 10 MΩ min. B: 1 MΩ min. C: 1 MΩ min. D: 1 MΩ min. Allowabl...

https://www.ia.omron.com/product/item/65197/

K3HB-XVD-T2 AC100-240 | OMRON Industrial Automatio...
...t Measurement range A: ±199.99 V B: ±19.999 V C: ±1.9999 V D: 1.0000 to 5.0000 V Accuracy ±0.1% rdg ±1 digit max. Input impedance A: 10 MΩ min. B: 1 MΩ min. C: 1 MΩ min. D: 1 MΩ min. Allowabl...

https://www.ia.omron.com/product/item/65198/

K3HB-XVD-T23 AC100-240 | OMRON Industrial Automati...
...t Measurement range A: ±199.99 V B: ±19.999 V C: ±1.9999 V D: 1.0000 to 5.0000 V Accuracy ±0.1% rdg ±1 digit max. Input impedance A: 10 MΩ min. B: 1 MΩ min. C: 1 MΩ min. D: 1 MΩ min. Allowabl...

https://www.ia.omron.com/product/item/65199/

FAQ00705 for Digital Panel Indicators | OMRON Indu...
...measuring accuracy for K3NR operating mode 1 (rotational/circumferential speed) is ±0.006% rdg ±1 digit. If the variation of input pulses is not considered, the error depends on the...

https://www.ia.omron.com/support/faq/answer/62/faq00705/

K3HB-X Process Indicator/Specifications | OMRON In...
...stantaneous overload (30 s) K3HB-XVD DC voltage A ±199.99 V -199.99 to 219.99 V 10 MΩ min. ±0.1%rdg ± 1 digit max. ±400 V B ±19.999 V -19.999 to 21.999 V 1 MΩ min. ±200 V C ±1.9999 V -1.9999 ...

https://www.ia.omron.com/products/family/1535/specification.html

S8AS Smart Power Supply/Specifications | OMRON Ind...
...max. Display functions Output voltage display Display range:17.0 to 30.0 V Display accuracy: 2% rdg ±1 digit max. Output current display Branch output display range: 0.0 to 4.0 A Peak output ...

https://www.ia.omron.com/products/family/1948/specification.html

ES1-N Infrared Thermosensor/Specifications | OMRON...
...mption 30 mA max. (24 VDC) Cable length 2 m ±5 cm Measurement accuracy USB output • Within ±(-8%rdg+1)°C (Measurement temperature: -50 to 0°C) • Within ±1°C (0 to 200°C) • Within ±0.5%...

https://www.ia.omron.com/products/family/3676/specification.html

K7GE-MG Insulation Resistance Monitoring Device/Sp...
...fications Measurement range 0.1 to 99.9 MΩ (0.0 MΩ for less than 0.1 MΩ) Measuring accuracy ±5% rdg. ±1 digit (at ambient temperature -10 to 55°C and ambient humidity 25% to 65%) Megger volta...

https://www.ia.omron.com/products/family/3811/specification.html

K7TM Heater Condition Monitoring Device/Specificat...
... Variations in CTs are not included. Repeat accuracy of resistance value (reference value): ±1% rdg ±1 digit Conditions: • When sine waves are input continuously • Variations in CTs are not i...

https://www.ia.omron.com/products/family/3855/specification.html

K7DD Advanced Motor Condition Monitoring Device/Sp...
... (Ambient temperature: 10 to 30°C) Current Absolute accuracy: 0.5%FS±1digit Repeat accuracy: ±1%rdg±1digit Not including accuracy variation of CTs The power frequency must be within the rated...

https://www.ia.omron.com/products/family/3893/specification.html

Results 241 - 250 of 261