FAQ02569 for Servomotors / Servo Drivers | OMRON I...
...control is possible by installing a DeviceNet Communications Unit (R88A-NCW152-DRT) in an OMNUC W-series Servo Driver. A DeviceNet Communications Unit provides a DeviceNet communications inte...

https://www.ia.omron.com/support/faq/answer/14/faq02569/

FAQ02058 for Solid-state Relays | OMRON Industrial...
...turned ON. This is more clearly checked if the dummy load is a lamp with an output of about 100 W. (However, the capacity of the lamp must be within the rated range of the SSR.) MY Best-selli...

https://www.ia.omron.com/support/faq/answer/18/faq02058/

FAQ02152 for Solid-state Relays | OMRON Industrial...
...ds can be directly switched without bleeder resistance. Bleeder Resistance 100 VAC 5 to 10 kΩ 3 W 200 VAC 5 to 10 kΩ 15 W Solid-state Relays with DC Output: Leakage current may cause...

https://www.ia.omron.com/support/faq/answer/18/faq02152/

FAQ02155 for Solid-state Relays | OMRON Industrial...
...tor must be checked to match the load, but previous experience shows that a resistor of 100 Ω/1 W and a capacitor of 0.1 μF/250 VAC will prevent reset failure. Also, as mentioned above, the l...

https://www.ia.omron.com/support/faq/answer/18/faq02155/

faq02235
...heat radiated by Solid-state Relays can be found using the following equation. Heating value P (W) = Output-ON voltage drop (V) x Carry current (A) For example, if a load current of 8 A flows...

https://www.ia.omron.com/support/faq/answer/18/faq02235/

FAQ02237 for Solid-state Relays | OMRON Industrial...
...with the power supply to keep the Solid-state Relay ON. Bleeder Resistance 100 VAC 5 to 10 kΩ 3 W 200 VAC 5 to 10 kΩ 15 W MY Best-selling, general-purpose relays that can be selected...

https://www.ia.omron.com/support/faq/answer/18/faq02237/

faq03116
...g method Surface mounting 8-pin socket 8-pin socket Flush mounting panel cutout 43.5 x 50.5 mm (W x H) (H3A-Y) 45 x 55 mm (W x H) (H3A + Y92F-40) 45 x 45 mm (W x H) (H3CR-A8...

https://www.ia.omron.com/support/faq/answer/19/faq03116/

faq03132
... type Flush mounting: 1 type Mounting method Surface mounting Three M4 screw holes 74 x 102 mm (W x H) Triangle (H2E, -P, 2) 80 x 120 mm (W x H) Triangle (H2E-M, MP) Two M3 screw hol...

https://www.ia.omron.com/support/faq/answer/19/faq03132/

faq03173
...Flush mounting) H3AM: 1 type (Flush mounting only) Flush mounting only panel cutout 52 x 66 mm (W x H) (TDS-Y) 53 x 65 mm (W x H) (TDS + Y92F-50) 81 dai. (TDS-LS) 45 x 45 mm (...

https://www.ia.omron.com/support/faq/answer/19/faq03173/

faq01858
...'s internal loss becomes heat energy (internal loss = heat produced). Equations: Internal loss (W) = Effective input power - Output power = Output power/Efficiency - Output power Note:Reducin...

https://www.ia.omron.com/support/faq/answer/22/faq01858/