Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 4661 - 4670 of 6516
E5CN-H Advanced Digital Temperature Controller (48...
...ance thermometer: Pt100 or JPt100 Current input: 4 to 20 mA or 0 to 20 mA Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V Input impedance Current input: 150 Ω max., Voltage ...

https://www.ia.omron.com/products/family/1946/specification.html

E5AN-H, E5EN-H Advanced Digital Temperature Contro...
...ance thermometer: Pt100 or JPt100 Current input: 4 to 20 mA or 0 to 20 mA Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V Input impedance Current input: 150 Ω max., Voltage ...

https://www.ia.omron.com/products/family/1947/specification.html

ZX2 Smart Sensors Laser Displacement Sensors CMOS ...
...W: 3 outputs), error output NPN open-collector outputs, 30 VDC, 50 mA max. (residual voltage: 1 V max. for load current 10 mA max., 2V max. for load current above 10 mA) PNP open-collector ou...

https://www.ia.omron.com/products/family/2979/specification.html

A22NK Key-type Selector Switches/Specifications | ...
...Push-In Plus terminal block type) Ratings Contacts (Standard Load) Rated insulation voltage 600 V Rated carry current 10 A Rated voltage 24 V 120 V 240 V 380 ...

https://www.ia.omron.com/products/family/3441/specification.html

A22NN / A22NL Pushbutton Switches/Specifications |...
...Push-In Plus terminal block type) Ratings Contacts (Standard Load) Rated insulation voltage 600 V Rated carry current 10 A Rated voltage 24 V 120 V 240 V 380 ...

https://www.ia.omron.com/products/family/3443/specification.html

A22NS / A22NW Selector Switches/Specifications | O...
...Push-In Plus terminal block type) Ratings Contacts (Standard Load) Rated insulation voltage 600 V Rated carry current 10 A Rated voltage 24 V 120 V 240 V 380 ...

https://www.ia.omron.com/products/family/3444/specification.html

A30NS / A30NW Selector Switches/Specifications | O...
...Push-In Plus terminal block type) Ratings Contacts (Standard Load) Rated insulation voltage 600 V Rated carry current 10 A Rated voltage 24 V 120 V 240 V 380 ...

https://www.ia.omron.com/products/family/3448/specification.html

A30NN / A30NL Pushbutton Switches/Specifications |...
...Push-In Plus terminal block type) Ratings Contacts (Standard Load) Rated insulation voltage 600 V Rated carry current 10 A Rated voltage 24 V 120 V 240 V 380 ...

https://www.ia.omron.com/products/family/3452/specification.html

E3Z Compact Photoelectric Sensor with Built-in Amp...
...: 26.4 VDC max., Load current: 100 mA max. Residual voltage: Load current of less than 10 mA: 1 V max. Load current of 10 to 100 mA: 2 V max. Open collector output (NPN/PNP depending...

https://www.ia.omron.com/products/family/407/specification.html

E3T Ultracompact, Ultrathin Photoelectric Sensor w...
...l output Load power supply voltage: 26.4 VDC max. Load current: 50 mA max. (residual voltage: 2 V max. for load current of 10 to 50 mA, 1 V max. for load current of less than 10 mA) ...

https://www.ia.omron.com/products/family/409/specification.html

Results 4661 - 4670 of 6516