Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 4661 - 4670 of 6521
A22NS / A22NW Selector Switches/Specifications | O...
...Push-In Plus terminal block type) Ratings Contacts (Standard Load) Rated insulation voltage 600 V Rated carry current 10 A Rated voltage 24 V 120 V 240 V 380 ...

https://www.ia.omron.com/products/family/3444/specification.html

A30NS / A30NW Selector Switches/Specifications | O...
...Push-In Plus terminal block type) Ratings Contacts (Standard Load) Rated insulation voltage 600 V Rated carry current 10 A Rated voltage 24 V 120 V 240 V 380 ...

https://www.ia.omron.com/products/family/3448/specification.html

A30NN / A30NL Pushbutton Switches/Specifications |...
...Push-In Plus terminal block type) Ratings Contacts (Standard Load) Rated insulation voltage 600 V Rated carry current 10 A Rated voltage 24 V 120 V 240 V 380 ...

https://www.ia.omron.com/products/family/3452/specification.html

E3Z Compact Photoelectric Sensor with Built-in Amp...
...: 26.4 VDC max., Load current: 100 mA max. Residual voltage: Load current of less than 10 mA: 1 V max. Load current of 10 to 100 mA: 2 V max. Open collector output (NPN/PNP depending...

https://www.ia.omron.com/products/family/407/specification.html

E3T Ultracompact, Ultrathin Photoelectric Sensor w...
...l output Load power supply voltage: 26.4 VDC max. Load current: 50 mA max. (residual voltage: 2 V max. for load current of 10 to 50 mA, 1 V max. for load current of less than 10 mA) ...

https://www.ia.omron.com/products/family/409/specification.html

E3C Compact Head Amplifier-separated Photoelectric...
...on manual Amplifier Units Model E3C-JC4P Power supply voltage 12 to 24 VDC±10%, ripple (p-p): 1 V max. Power (current) consumption 40 mA max. Control output Load power supply voltage: 24 VDC ...

https://www.ia.omron.com/products/family/423/specification.html

E2E DC 2-Wire (PUR Cable/Self-diagnosis Output), A...
...--- E2E-X2D1-U 2M NC E2E-X2D2-U 2M M12 Pre-wired Smartclick Connector Models (0.3 m) PUR NO 1: +V, 4: 0 V E2E-X2D1-M1TGJ-U 0.3M NC 1: +V, 2: 0 V E2E-X2D2-M1TGJ-U 0....

https://www.ia.omron.com/products/family/449/lineup.html

E2E DC 2-Wire (PUR Cable/Self-diagnosis Output), A...
...output Load current 3 to 100 mA, Diagnostic output: 50 mA for -D1(5)S Models Residual voltage 3 V max. (Load current: 100 mA, Cable length: 2 m) Indicators D1 Models: Operation indicator (red...

https://www.ia.omron.com/products/family/449/specification.html

E2EQ Spatter-resistant Proximity Sensor/Specificat...
...equency *2 1 kHz 0.5 kHz 0.25 kHz Control output Load current 3 to 100 mA Residual voltage *3 5 V max. (Load current: 100 mA, Cable length: 2 m) Operation mode (with sensing object approachin...

https://www.ia.omron.com/products/family/452/specification.html

E2FQ Chemical-resistant Proximity Sensor/Specifica...
...dels: 200 mA max., D1 Models: 5 to 100 mA, Y1 Models: 5 to 300 mA Residual voltage E1 Models: 2 V max. (Load current: 200 mA, Cable length: 2 m) Y1 Models: Refer to Engineering Data on Data S...

https://www.ia.omron.com/products/family/453/specification.html

Results 4661 - 4670 of 6521