A165S / W Knob-type Selector Switch (Detachable) (...
...ludes a Switch and a Lamp.) Appearance Number of notches Classification Model 2 notches SPDT 24 V Solder terminals A16W-2N[]-24D-1 DPDT A16W-2N[]-24D-2 3 notches DPDT A16W-3N[]-24D-2 Switch U...

https://www.ia.omron.com/products/family/1102/lineup.html

M16 Indicator (Cylindrical 16-dia.)/Lineup | OMRON...
...) 100/110 VAC/VDC M16-[1]-T1-S 200/220 VAC/VDC M16-[1]-T2-S Note: 1. The LED built into the 100-V model is 24 VAC/VDC.           2. The LED built into the 200-V model is high-intensi...

https://www.ia.omron.com/products/family/1105/lineup.html

A22 Pushbutton Switch (Cylindrical 22/25-dia.)/Spe...
...Rated current Operating voltage Applicable lamp (BA9S/Base: 13) 110 VAC 8 mA 100 VAC (95 to 115 V) LED Lamp (A22-24A[]) 220 VAC 200 VAC (190 to 230 V) Characteristics Type Pushbutton...

https://www.ia.omron.com/products/family/1108/specification.html

A22NE-PD / A22NE-P / A22E Emergency Stop Pushbutto...
... CSA C22.2 No. 14 has been obtained. Ratings Contacts (Standard Load) Rated insulation voltage (V) Rated carry current (A) Rated voltage (V) Rated current (A) AC15 (Inductive load) A...

https://www.ia.omron.com/products/family/1111/specification.html

A3P Lighted Pushbutton Switches/Specifications | O...
...re certified. Ratings Contact Ratings Silver Alloy Contacts (for Standard Loads) Rated voltage (V) Non-inductive load (A) Inductive load (A) Resistive load Lamp load Inductive load Motor load...

https://www.ia.omron.com/products/family/1120/specification.html

D4F Small Safety Limit Switch/Specifications | OMR...
...tem AC-15 DC-13 Rated operating current (I e ) 0.75 A 0.27 A Rated operating voltage (U e ) 240 V 250 V Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circu...

https://www.ia.omron.com/products/family/1327/specification.html

E6C3-A Slim Encoder with Diameter of 50 mm/Specifi...
...put Output capacity Applied voltage: 30 VDC max. Sink current: 35 mA max. Residual voltage: 0.4 V max. (at sink current of 35 mA) Source current: 35 mA max. Residual voltage: 0.4 V m...

https://www.ia.omron.com/products/family/1347/specification.html

DRT2-[]D04CL(-1) / []D08C(-1) / []D08CL(-1) / []D1...
...D08C-1 Internal I/O common NPN PNP I/O points 8 inputs ON voltage 9 VDC min. (between input and V terminal) 9 VDC min. (between input and G terminal) OFF voltage 5 VDC max. (between input and...

https://www.ia.omron.com/products/family/1354/specification.html

D4NL Guard Lock Safety-door Switch/Specifications ...
...n category AC-15 DC-13 Rated operating current (Ie) 3 A 0.27 A Rated operating voltage (Ue) 240 V 250 V Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circu...

https://www.ia.omron.com/products/family/1357/specification.html

CJ1W-NC[][]3 CJ series Position Control Units/Line...
...nsumption (A) Model Standards Control method/ Control output interface Number of control axes 5 V system 24 V system CJ1 Special I/O Units Position control unit Open-loop control by ...