K3HB-P Timer Interval Indicator/Specifications | O...
...ent inputs *2 Hold input NPN open collector or no-voltage contact signal ON residual voltage: 2 V max. ON current at 0 Ω: 4 mA max. Max. applied voltage: 30 VDC max. OFF leakage current: 0.1 ...

https://www.ia.omron.com/products/family/1539/specification.html

E3S Photoelectric Sensor with Built-in Amplifier/S...
...(solid-state output) Output current: 1.5 to 4 mA, Load current: 80 mA max. (residual voltage: 2 V max.) Refer to Data Sheet. Response time Operate or reset: 3 ms max. Operate or reset: 1 ms m...

https://www.ia.omron.com/products/family/1568/specification.html

NE1A-SCPU Series Safety Network Controller/Specifi...
...tput type Sourcing outputs (PNP) Rated output current 0.5 A max./output ON residual voltage 1.2 V max. between each output terminal and V2 Leakage current 0.1 mA max. Test Output Specificatio...

https://www.ia.omron.com/products/family/1625/specification.html

CJ1W-PA / PD CJ-series Power Supply Unit/Specifica...
... 1, 2021 Item Specifications Model CJ1W-PA205R CJ1W-PA205C CJ1W-PA202 Supply voltage 100 to 240 V AC (wide-range), 50/60 Hz Operating voltage and frequency ranges 85 to 264 V AC, 47 ...

https://www.ia.omron.com/products/family/1639/specification.html

CJ1W-AD / DA / MAD CJ-Series Analog I/O Unit/Lineu...
...ion period Accuracy at ambient temperature of 25 °C Current consump- tion (A) Model Standards 5 V 24 V Analog Input Unit (High-speed type) 4 inputs 1 to 5 V (1/10,000), 0 to...

https://www.ia.omron.com/products/family/1645/lineup.html

CJ1W-AD / DA / MAD CJ-Series Analog I/O Unit/Speci...
...or CJ Series. Input specifi- cations Number of analog inputs 4 8 4 Input signal range *2 1 to 5 V 0 to 5 V 0 to 10 V - 10 to 10 V 4 to 20 mA *3 1 to 5 V 0 ...

https://www.ia.omron.com/products/family/1645/specification.html

CJ1W-CT021 CJ-series High-speed Counter Unit/Speci...
...nt Operating Humidity 10% to 90% without condensation Internal Current Consumption 280 mA (at 5 V) Dimensions 31 × 90 × 65 mm (W × H × D) Weight 100 g Mounting Position CJ-series CPU Rack or ...

https://www.ia.omron.com/products/family/1649/specification.html

CJ1W-SCU CJ-series Serial Communications Units/Spe...
...   added for each port to which an NT-AL001 Link Adapter is connected to provide the required 5-V power supply. *4. Final order entry date for CJ1M:The end of March, 2021 Protocol Specificati...

https://www.ia.omron.com/products/family/1651/specification.html

E5CS Temperature Controllers/Specifications | OMRO...
...ct discharge (level 2), 8 kV air discharge (level 3) RF-interference Immunity: EN 61000-4-3: 10 V/m (80-1000 MHz, 1.4-2.0 GHz amplitude modulated) (level 3), 10 V/m (900 MHz pulse mo...

https://www.ia.omron.com/products/family/166/specification.html

CS1W-AD SYSMAC CS-series Analog I/O Unit/Specifica...
...words per Unit Input specifications Number of analog inputs 4 8 16 Input signal range *5 1 to 5 V 0 to 5 V 0 to 10 V - 10 to 10 V 4 to 20 mA *6 Maximum rated input ...

https://www.ia.omron.com/products/family/1666/specification.html